Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias

Detalhes bibliográficos
Autor(a) principal: Vieira, Sabrina Nunes
Data de Publicação: 2007
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFU
Texto Completo: https://repositorio.ufu.br/handle/123456789/17458
Resumo: Modified electrodes can be used in selective interactions, pre-concentration, electrocatalysis, permselective membranes and incorporation of biomolecules, contributing, in this way, to increase the sensibility and selectivity of an analytical measurement. Polymeric films represent an alternative in the modification of an electrode. Non-conducting polymers presents high resistivity, which limits the films growing, offering a low diffusional barrier. These polymers are used as permselective membranes avoiding the approach of interferent species on the electrode surface. Conducting polymers presents unusual properties as electric conductivity, low energy of optical transmission, low ionization potential and high electronic affinity. These polymers are called synthetical metals because they have electronic properties similar to that one from metals. The use of conducting and non-conducting polymeric films has attracted considerable interest on the development of amperometric biosensors, due to its unique properties. Biosensor is a device that employs a biological recognition element attached to a transducer. Biosensors offers some advantages as high sensibility and selectivity, response in real time, potential to be miniaturized, possibility to an in situ monitoration, easily handed, which justify its employ in analytical measurements. Biosensors represents a promising tool in the detection of hepatopaties due to its unique characteristics as the possibility of the construction of simple and portable devices to an fast on site monitoration. In this way, the use of biosensors enables a precocious diagnosis of hepatopaties, belonging in a group of illnesses that causes a great number of deaths. This work proposes to contribute to the development of a biosensor to the detection of diseases that attacks the liver. This biosensor will be constructed as a modified electrode with a polymeric film from 4-aminophenol, electrochemically deposited, in which will be incorporated L-alanine and α-ketoglutarate as recognition elements of alanine aminotransferase (ALT), enzyme presents in a great amount in human blood attacked by any kind of hepatic injury.
id UFU_3bca17ef9ee90dc2cb8da4009611d848
oai_identifier_str oai:repositorio.ufu.br:123456789/17458
network_acronym_str UFU
network_name_str Repositório Institucional da UFU
repository_id_str
spelling 2016-06-22T18:48:42Z2007-08-172016-06-22T18:48:42Z2007-02-23VIEIRA, Sabrina Nunes. Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias. 2007. 75 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de Uberlândia, Uberlândia, 2007.https://repositorio.ufu.br/handle/123456789/17458Modified electrodes can be used in selective interactions, pre-concentration, electrocatalysis, permselective membranes and incorporation of biomolecules, contributing, in this way, to increase the sensibility and selectivity of an analytical measurement. Polymeric films represent an alternative in the modification of an electrode. Non-conducting polymers presents high resistivity, which limits the films growing, offering a low diffusional barrier. These polymers are used as permselective membranes avoiding the approach of interferent species on the electrode surface. Conducting polymers presents unusual properties as electric conductivity, low energy of optical transmission, low ionization potential and high electronic affinity. These polymers are called synthetical metals because they have electronic properties similar to that one from metals. The use of conducting and non-conducting polymeric films has attracted considerable interest on the development of amperometric biosensors, due to its unique properties. Biosensor is a device that employs a biological recognition element attached to a transducer. Biosensors offers some advantages as high sensibility and selectivity, response in real time, potential to be miniaturized, possibility to an in situ monitoration, easily handed, which justify its employ in analytical measurements. Biosensors represents a promising tool in the detection of hepatopaties due to its unique characteristics as the possibility of the construction of simple and portable devices to an fast on site monitoration. In this way, the use of biosensors enables a precocious diagnosis of hepatopaties, belonging in a group of illnesses that causes a great number of deaths. This work proposes to contribute to the development of a biosensor to the detection of diseases that attacks the liver. This biosensor will be constructed as a modified electrode with a polymeric film from 4-aminophenol, electrochemically deposited, in which will be incorporated L-alanine and α-ketoglutarate as recognition elements of alanine aminotransferase (ALT), enzyme presents in a great amount in human blood attacked by any kind of hepatic injury.Eletrodos modificados podem ser usados em interações seletivas, pré-concentração, eletrocatálise, membranas permesseletivas e incorporação de biomoléculas, contribuindo desta forma para aumentar a sensibilidade e seletividade de uma medida analítica. Filmes poliméricos representam uma alternativa na modificação de um eletrodo. Polímeros não condutores apresentam alta resistividade, o que torna o crescimento destes filmes limitado, oferecendo uma baixa barreira difusional. Estes polímeros são usados como membranas permesseletivas evitando a aproximação de uma espécie interferente da superfície eletródica. Polímeros condutores apresentam propriedades incomuns como condutividade elétrica, baixa energia de transmissão ótica, baixo potencial de ionização e alta afinidade eletrônica. Estes polímeros são chamados de metais sintéticos, pois são polímeros com propriedades eletrônicas similar às dos metais. O uso de filmes poliméricos condutores e não condutores têm atraído considerável interesse no desenvolvimento de biossensores amperométricos, devido às suas propriedades únicas. Biossensor é um dispositivo que emprega um elemento de reconhecimento biológico intimamente acoplado a um transdutor. Biossensores oferecem algumas vantagens como alta sensibilidade, resposta em tempo real, potencial para miniaturização, alta seletividade, possibilidade de monitoramento in situ, fácil manuseio, o que justifica seu emprego em medidas analíticas. Biossensores representam uma ferramenta promissora na detecção de hepatopatias devido as suas características únicas como a possibilidade de construção de equipamentos simples e portáteis para um monitoramento on site rápido. Desta forma o uso de biossensores possibilita o diagnóstico precoce de hepatopatias, que formam um grupo de doenças que ocasionam um grande número de óbitos. Este trabalho se propõe a contribuir para o desenvolvimento de um biossensor para a detecção de doenças que afetam o fígado. Este biossensor será construído com base em um eletrodo modificado com filme polimérico derivado de 4-aminofenol depositado eletroquimicamente, ao qual serão incorporados L-alanina e α-cetoglutarato como elementos de reconhecimento de alanina aminotransferase (ALT), enzima presente em grande quantidade no sangue de humanos acometidos por algum tipo de lesão hepática.Fundação de Amparo a Pesquisa do Estado de Minas GeraisMestre em Químicaapplication/pdfporUniversidade Federal de UberlândiaPrograma de Pós-graduação em QuímicaUFUBRCiências Exatas e da TerraBiossensores eletroquímicos-HepatopatiasQuimica orgânicaCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICAContribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatiasinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisMadurro, Ana Graci Britohttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4709037T3Madurro, João Marcoshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4782738T7Cho, Liu Yaohttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4723569Y0Bottecchia, Otavio Luizhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4785456D6http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4774699Z8Vieira, Sabrina Nunesinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFUinstname:Universidade Federal de Uberlândia (UFU)instacron:UFUTHUMBNAILSNVieiraDISPRT.pdf.jpgSNVieiraDISPRT.pdf.jpgGenerated Thumbnailimage/jpeg1434https://repositorio.ufu.br/bitstream/123456789/17458/3/SNVieiraDISPRT.pdf.jpgc1575c47f6fc2cce0e41ab26ed6d1a92MD53ORIGINALSNVieiraDISPRT.pdfapplication/pdf4271850https://repositorio.ufu.br/bitstream/123456789/17458/1/SNVieiraDISPRT.pdffaaa00c647cda30d2bb44a8acc7e0160MD51TEXTSNVieiraDISPRT.pdf.txtSNVieiraDISPRT.pdf.txtExtracted texttext/plain117499https://repositorio.ufu.br/bitstream/123456789/17458/2/SNVieiraDISPRT.pdf.txteee9e5e9156599500ee5679ec485ff93MD52123456789/174582016-06-23 04:51:18.781oai:repositorio.ufu.br:123456789/17458Repositório InstitucionalONGhttp://repositorio.ufu.br/oai/requestdiinf@dirbi.ufu.bropendoar:2016-06-23T07:51:18Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)false
dc.title.por.fl_str_mv Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias
title Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias
spellingShingle Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias
Vieira, Sabrina Nunes
Biossensores eletroquímicos-Hepatopatias
Quimica orgânica
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias
title_full Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias
title_fullStr Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias
title_full_unstemmed Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias
title_sort Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias
author Vieira, Sabrina Nunes
author_facet Vieira, Sabrina Nunes
author_role author
dc.contributor.advisor-co1.fl_str_mv Madurro, Ana Graci Brito
dc.contributor.advisor-co1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4709037T3
dc.contributor.advisor1.fl_str_mv Madurro, João Marcos
dc.contributor.advisor1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4782738T7
dc.contributor.referee1.fl_str_mv Cho, Liu Yao
dc.contributor.referee1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4723569Y0
dc.contributor.referee2.fl_str_mv Bottecchia, Otavio Luiz
dc.contributor.referee2Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4785456D6
dc.contributor.authorLattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4774699Z8
dc.contributor.author.fl_str_mv Vieira, Sabrina Nunes
contributor_str_mv Madurro, Ana Graci Brito
Madurro, João Marcos
Cho, Liu Yao
Bottecchia, Otavio Luiz
dc.subject.por.fl_str_mv Biossensores eletroquímicos-Hepatopatias
Quimica orgânica
topic Biossensores eletroquímicos-Hepatopatias
Quimica orgânica
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
description Modified electrodes can be used in selective interactions, pre-concentration, electrocatalysis, permselective membranes and incorporation of biomolecules, contributing, in this way, to increase the sensibility and selectivity of an analytical measurement. Polymeric films represent an alternative in the modification of an electrode. Non-conducting polymers presents high resistivity, which limits the films growing, offering a low diffusional barrier. These polymers are used as permselective membranes avoiding the approach of interferent species on the electrode surface. Conducting polymers presents unusual properties as electric conductivity, low energy of optical transmission, low ionization potential and high electronic affinity. These polymers are called synthetical metals because they have electronic properties similar to that one from metals. The use of conducting and non-conducting polymeric films has attracted considerable interest on the development of amperometric biosensors, due to its unique properties. Biosensor is a device that employs a biological recognition element attached to a transducer. Biosensors offers some advantages as high sensibility and selectivity, response in real time, potential to be miniaturized, possibility to an in situ monitoration, easily handed, which justify its employ in analytical measurements. Biosensors represents a promising tool in the detection of hepatopaties due to its unique characteristics as the possibility of the construction of simple and portable devices to an fast on site monitoration. In this way, the use of biosensors enables a precocious diagnosis of hepatopaties, belonging in a group of illnesses that causes a great number of deaths. This work proposes to contribute to the development of a biosensor to the detection of diseases that attacks the liver. This biosensor will be constructed as a modified electrode with a polymeric film from 4-aminophenol, electrochemically deposited, in which will be incorporated L-alanine and α-ketoglutarate as recognition elements of alanine aminotransferase (ALT), enzyme presents in a great amount in human blood attacked by any kind of hepatic injury.
publishDate 2007
dc.date.available.fl_str_mv 2007-08-17
2016-06-22T18:48:42Z
dc.date.issued.fl_str_mv 2007-02-23
dc.date.accessioned.fl_str_mv 2016-06-22T18:48:42Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv VIEIRA, Sabrina Nunes. Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias. 2007. 75 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de Uberlândia, Uberlândia, 2007.
dc.identifier.uri.fl_str_mv https://repositorio.ufu.br/handle/123456789/17458
identifier_str_mv VIEIRA, Sabrina Nunes. Contribuição para o desenvolvimento de biossensores eletroquímicos para detecção de hapatopatias. 2007. 75 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de Uberlândia, Uberlândia, 2007.
url https://repositorio.ufu.br/handle/123456789/17458
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Uberlândia
dc.publisher.program.fl_str_mv Programa de Pós-graduação em Química
dc.publisher.initials.fl_str_mv UFU
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Ciências Exatas e da Terra
publisher.none.fl_str_mv Universidade Federal de Uberlândia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFU
instname:Universidade Federal de Uberlândia (UFU)
instacron:UFU
instname_str Universidade Federal de Uberlândia (UFU)
instacron_str UFU
institution UFU
reponame_str Repositório Institucional da UFU
collection Repositório Institucional da UFU
bitstream.url.fl_str_mv https://repositorio.ufu.br/bitstream/123456789/17458/3/SNVieiraDISPRT.pdf.jpg
https://repositorio.ufu.br/bitstream/123456789/17458/1/SNVieiraDISPRT.pdf
https://repositorio.ufu.br/bitstream/123456789/17458/2/SNVieiraDISPRT.pdf.txt
bitstream.checksum.fl_str_mv c1575c47f6fc2cce0e41ab26ed6d1a92
faaa00c647cda30d2bb44a8acc7e0160
eee9e5e9156599500ee5679ec485ff93
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)
repository.mail.fl_str_mv diinf@dirbi.ufu.br
_version_ 1802110548221886464