Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino

Detalhes bibliográficos
Autor(a) principal: Thompson Júnior, José Pedro
Data de Publicação: 2013
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFU
Texto Completo: https://repositorio.ufu.br/handle/123456789/17398
Resumo: This work investigated the technique of flotation by dissolved air for effluent treatment generated by Industrial Laundries. Effluents from industrial laundries, as a whole, contain dirt removed from clothes, outfits and IPE s, and substances added in the washing processes, which are normally treated in the coagulation/flocculation and sedimentation physical-chemical processes. In this work, bench tests were made aimed at finding an optimized methodology for the formation of flakes in the coagulation/flocculation phases with formats and densities suitable for the separation of sludge by flotation by dissolved air into an effluent from an industrial laundry. The tests were made in a jar test\" equipment with jars adapted for injection of saturated water, using tannins as coagulating agent and anionic polyelectrolyte as flocculating agent. This methodology also searched to improve the solid-liquid separation phase by using flotation by dissolved air, a not very common alternative for this type of effluent (high concentration of solids). The best results of turbidity removal were obtained with 400 ppm of Aluminum Sulphate and 770 ppm of Tanfloc SL, with 1.5 and 2.9 NTU, or removal efficiency of 99.9% and 99.7%, respectively. This work investigated the production conditions of air saturated water, by varying the saturation pressures at 2.5, 4.0, and 5.0 Kg/cm2, by varying the surfactant concentration Sodium Dodecyl Sulphate in air saturated water at 0, 10, 20 ppm. The control parameters were: volume of formed sludge, turbidity indexes of the treated effluent and solid-liquid separation time. The results shown in the tests with saturated water with pressures adjusted at 4.0 Kgf/cm2 and 5.0 Kgf/cm2 were the best ones on all parameters seen in this phase, with the transportation capacity of the sludge to the jar surface, the stability, and sludge volume (settling or compaction). As regards the saturated water production, the lowest turbidity indexes and formed sludge volume were obtained when 10 ppm and 20 ppm of surfactant Sodium Dodecyl Sulphate were added in the saturated water, pressure set at 2.5 Kgf/cm2 and applied at the proportion of 17.5% (saturated water/effluent). It was also observed that in the solid/liquid separation phase via flotation by dissolved water turbidity removals were obtained at the range of 99.8% and 99.7% for the coagulants, Aluminum Sulphate (inorganic) and cationic tannin (biodegradable organic), respectively. As regards the separation time, the FDA presented lower separation times for both coagulants, as compared with conventional decantation.
id UFU_3d152e81e0e88a66daea2341e7fe6277
oai_identifier_str oai:repositorio.ufu.br:123456789/17398
network_acronym_str UFU
network_name_str Repositório Institucional da UFU
repository_id_str
spelling 2016-06-22T18:48:34Z2014-02-172016-06-22T18:48:34Z2013-02-22THOMPSON JÚNIOR, José Pedro. Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino. 2013. 122 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de Uberlândia, Uberlândia, 2013.https://repositorio.ufu.br/handle/123456789/17398This work investigated the technique of flotation by dissolved air for effluent treatment generated by Industrial Laundries. Effluents from industrial laundries, as a whole, contain dirt removed from clothes, outfits and IPE s, and substances added in the washing processes, which are normally treated in the coagulation/flocculation and sedimentation physical-chemical processes. In this work, bench tests were made aimed at finding an optimized methodology for the formation of flakes in the coagulation/flocculation phases with formats and densities suitable for the separation of sludge by flotation by dissolved air into an effluent from an industrial laundry. The tests were made in a jar test\" equipment with jars adapted for injection of saturated water, using tannins as coagulating agent and anionic polyelectrolyte as flocculating agent. This methodology also searched to improve the solid-liquid separation phase by using flotation by dissolved air, a not very common alternative for this type of effluent (high concentration of solids). The best results of turbidity removal were obtained with 400 ppm of Aluminum Sulphate and 770 ppm of Tanfloc SL, with 1.5 and 2.9 NTU, or removal efficiency of 99.9% and 99.7%, respectively. This work investigated the production conditions of air saturated water, by varying the saturation pressures at 2.5, 4.0, and 5.0 Kg/cm2, by varying the surfactant concentration Sodium Dodecyl Sulphate in air saturated water at 0, 10, 20 ppm. The control parameters were: volume of formed sludge, turbidity indexes of the treated effluent and solid-liquid separation time. The results shown in the tests with saturated water with pressures adjusted at 4.0 Kgf/cm2 and 5.0 Kgf/cm2 were the best ones on all parameters seen in this phase, with the transportation capacity of the sludge to the jar surface, the stability, and sludge volume (settling or compaction). As regards the saturated water production, the lowest turbidity indexes and formed sludge volume were obtained when 10 ppm and 20 ppm of surfactant Sodium Dodecyl Sulphate were added in the saturated water, pressure set at 2.5 Kgf/cm2 and applied at the proportion of 17.5% (saturated water/effluent). It was also observed that in the solid/liquid separation phase via flotation by dissolved water turbidity removals were obtained at the range of 99.8% and 99.7% for the coagulants, Aluminum Sulphate (inorganic) and cationic tannin (biodegradable organic), respectively. As regards the separation time, the FDA presented lower separation times for both coagulants, as compared with conventional decantation.Os efluentes de lavanderias industriais, de maneira geral, contêm sujeiras removidas das roupas, uniformes e EPIs e substâncias adicionadas nos processos de lavagens, que normalmente são tratados por processos físico-químicos de coagulação/floculação e sedimentação. Neste trabalho foram realizados ensaios de bancada objetivando a determinação de uma metodologia otimizada para formação de flocos nas etapas de coagulação/floculação com formatos e densidades propícios para separação do lodo por flotação por ar dissolvido para um efluente proveniente de uma lavanderia industrial. Os ensaios foram realizados em aparelho \"jartest\" com jarros adaptados para a injeção de água saturada, utilizando o tanino como agente coagulante e polieletrólito aniônico como agente floculante. Esta metodologia buscou também aperfeiçoar a etapa de separação sólido-líquido com o emprego da flotação por ar dissolvido, alternativa esta, não muito comum para esta característica de efluente (elevada concentração de sólidos). Os melhores resultados de remoção de turbidez foram obtidos com 400 ppm de sulfato de alumínio e 770 ppm de Tanfloc SL, sendo 1,5 e 2,9 NTU ou eficiência de remoção de 99,9 e 99,7%, respectivamente. Neste trabalho também foram investigadas as condições de produção de água saturada com ar, variando as pressões de saturação em 2,5, 4,0 e 5,0 Kgf/cm2 e variando-se a concentração de surfactante Dodecil Sulfato de Sódio na água saturada com ar em 0, 10 e 20 ppm. Os parâmetros de controle foram: volume de lodo formado, índices de turbidez do efluente tratado e tempo de separação sólido-líquido. Os resultados apresentados nos ensaios com água saturada com as pressões ajustadas em 4,0 Kgf/cm2 e 5,0 Kgf/cm2, foram melhores em todos os parâmetros observados nesta etapa, sendo, a capacidade no transporte do lodo para a superfície do jarro, a estabilidade e o volume de lodo (assentamento ou compactação). Quanto a produção de água saturada, os menores índices de turbidez e volume de lodo formado foram obtidos quando adicionado 10 e 20 ppm de surfactante Dodecil Sulfato de Sódio na água saturada, pressão ajustada em 2,5 Kgf/cm2 e aplicada em proporção de 17,5% (água saturada/efluente). Observou-se também que, no processo de separação sólido/líquido via flotação por ar dissolvido foram obtidas remoções de turbidez na ordem de 99,8% e 99,7% para os coagulantes sulfato de alumínio (inorgânico) e tanino catiônico (orgânico biodegradável), respectivamente. Quanto ao tempo de separação, a FAD apresentou menores tempos de separação para ambos os coagulantes comparada à decantação convencional.Fundação de Amparo a Pesquisa do Estado de Minas GeraisMestre em Químicaapplication/pdfporUniversidade Federal de UberlândiaPrograma de Pós-graduação em QuímicaUFUBRCiências Exatas e da TerraFlotação por ar dissolvidoTratamento de efluente de lavanderias industriaisCoagulante orgânicoTanino catiônicoFlotaçãoTaninosCoagulaçãoLavanderias e tinturariasResíduos industriaisDissolved air flotationTreatment of effluentIndustrial laundriesCoagulant organicCationic tanninCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICAInvestigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável taninoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisCanobre, Sheila Cristinahttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4775037T8Amaral, Fábio Augusto dohttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4763451Y3Pasquini, Danielhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4768202P8Lima, José Renato Baptistahttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4797677E6http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4292677U9Thompson Júnior, José Pedroinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFUinstname:Universidade Federal de Uberlândia (UFU)instacron:UFUTHUMBNAILInvestigacaoFlotacaoAr.pdf.jpgInvestigacaoFlotacaoAr.pdf.jpgGenerated Thumbnailimage/jpeg1564https://repositorio.ufu.br/bitstream/123456789/17398/3/InvestigacaoFlotacaoAr.pdf.jpgff4cc9abd55863a8227547ce63391a46MD53ORIGINALInvestigacaoFlotacaoAr.pdfapplication/pdf4754448https://repositorio.ufu.br/bitstream/123456789/17398/1/InvestigacaoFlotacaoAr.pdf69c283f0b94d2016185adc9d7e774cabMD51TEXTInvestigacaoFlotacaoAr.pdf.txtInvestigacaoFlotacaoAr.pdf.txtExtracted texttext/plain189327https://repositorio.ufu.br/bitstream/123456789/17398/2/InvestigacaoFlotacaoAr.pdf.txt44b8aeb02e7adbb4059387900c30d990MD52123456789/173982019-08-20 10:29:30.977oai:repositorio.ufu.br:123456789/17398Repositório InstitucionalONGhttp://repositorio.ufu.br/oai/requestdiinf@dirbi.ufu.bropendoar:2019-08-20T13:29:30Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)false
dc.title.por.fl_str_mv Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino
title Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino
spellingShingle Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino
Thompson Júnior, José Pedro
Flotação por ar dissolvido
Tratamento de efluente de lavanderias industriais
Coagulante orgânico
Tanino catiônico
Flotação
Taninos
Coagulação
Lavanderias e tinturarias
Resíduos industriais
Dissolved air flotation
Treatment of effluent
Industrial laundries
Coagulant organic
Cationic tannin
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino
title_full Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino
title_fullStr Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino
title_full_unstemmed Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino
title_sort Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino
author Thompson Júnior, José Pedro
author_facet Thompson Júnior, José Pedro
author_role author
dc.contributor.advisor-co1.fl_str_mv Canobre, Sheila Cristina
dc.contributor.advisor-co1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4775037T8
dc.contributor.advisor1.fl_str_mv Amaral, Fábio Augusto do
dc.contributor.advisor1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4763451Y3
dc.contributor.referee1.fl_str_mv Pasquini, Daniel
dc.contributor.referee1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4768202P8
dc.contributor.referee2.fl_str_mv Lima, José Renato Baptista
dc.contributor.referee2Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4797677E6
dc.contributor.authorLattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4292677U9
dc.contributor.author.fl_str_mv Thompson Júnior, José Pedro
contributor_str_mv Canobre, Sheila Cristina
Amaral, Fábio Augusto do
Pasquini, Daniel
Lima, José Renato Baptista
dc.subject.por.fl_str_mv Flotação por ar dissolvido
Tratamento de efluente de lavanderias industriais
Coagulante orgânico
Tanino catiônico
Flotação
Taninos
Coagulação
Lavanderias e tinturarias
Resíduos industriais
topic Flotação por ar dissolvido
Tratamento de efluente de lavanderias industriais
Coagulante orgânico
Tanino catiônico
Flotação
Taninos
Coagulação
Lavanderias e tinturarias
Resíduos industriais
Dissolved air flotation
Treatment of effluent
Industrial laundries
Coagulant organic
Cationic tannin
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
dc.subject.eng.fl_str_mv Dissolved air flotation
Treatment of effluent
Industrial laundries
Coagulant organic
Cationic tannin
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
description This work investigated the technique of flotation by dissolved air for effluent treatment generated by Industrial Laundries. Effluents from industrial laundries, as a whole, contain dirt removed from clothes, outfits and IPE s, and substances added in the washing processes, which are normally treated in the coagulation/flocculation and sedimentation physical-chemical processes. In this work, bench tests were made aimed at finding an optimized methodology for the formation of flakes in the coagulation/flocculation phases with formats and densities suitable for the separation of sludge by flotation by dissolved air into an effluent from an industrial laundry. The tests were made in a jar test\" equipment with jars adapted for injection of saturated water, using tannins as coagulating agent and anionic polyelectrolyte as flocculating agent. This methodology also searched to improve the solid-liquid separation phase by using flotation by dissolved air, a not very common alternative for this type of effluent (high concentration of solids). The best results of turbidity removal were obtained with 400 ppm of Aluminum Sulphate and 770 ppm of Tanfloc SL, with 1.5 and 2.9 NTU, or removal efficiency of 99.9% and 99.7%, respectively. This work investigated the production conditions of air saturated water, by varying the saturation pressures at 2.5, 4.0, and 5.0 Kg/cm2, by varying the surfactant concentration Sodium Dodecyl Sulphate in air saturated water at 0, 10, 20 ppm. The control parameters were: volume of formed sludge, turbidity indexes of the treated effluent and solid-liquid separation time. The results shown in the tests with saturated water with pressures adjusted at 4.0 Kgf/cm2 and 5.0 Kgf/cm2 were the best ones on all parameters seen in this phase, with the transportation capacity of the sludge to the jar surface, the stability, and sludge volume (settling or compaction). As regards the saturated water production, the lowest turbidity indexes and formed sludge volume were obtained when 10 ppm and 20 ppm of surfactant Sodium Dodecyl Sulphate were added in the saturated water, pressure set at 2.5 Kgf/cm2 and applied at the proportion of 17.5% (saturated water/effluent). It was also observed that in the solid/liquid separation phase via flotation by dissolved water turbidity removals were obtained at the range of 99.8% and 99.7% for the coagulants, Aluminum Sulphate (inorganic) and cationic tannin (biodegradable organic), respectively. As regards the separation time, the FDA presented lower separation times for both coagulants, as compared with conventional decantation.
publishDate 2013
dc.date.issued.fl_str_mv 2013-02-22
dc.date.available.fl_str_mv 2014-02-17
2016-06-22T18:48:34Z
dc.date.accessioned.fl_str_mv 2016-06-22T18:48:34Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv THOMPSON JÚNIOR, José Pedro. Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino. 2013. 122 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de Uberlândia, Uberlândia, 2013.
dc.identifier.uri.fl_str_mv https://repositorio.ufu.br/handle/123456789/17398
identifier_str_mv THOMPSON JÚNIOR, José Pedro. Investigação da flotação por ar dissolvido no tratamento de efluente de lavanderia industrial utilizando coagulante de fonte renovável tanino. 2013. 122 f. Dissertação (Mestrado em Ciências Exatas e da Terra) - Universidade Federal de Uberlândia, Uberlândia, 2013.
url https://repositorio.ufu.br/handle/123456789/17398
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Uberlândia
dc.publisher.program.fl_str_mv Programa de Pós-graduação em Química
dc.publisher.initials.fl_str_mv UFU
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Ciências Exatas e da Terra
publisher.none.fl_str_mv Universidade Federal de Uberlândia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFU
instname:Universidade Federal de Uberlândia (UFU)
instacron:UFU
instname_str Universidade Federal de Uberlândia (UFU)
instacron_str UFU
institution UFU
reponame_str Repositório Institucional da UFU
collection Repositório Institucional da UFU
bitstream.url.fl_str_mv https://repositorio.ufu.br/bitstream/123456789/17398/3/InvestigacaoFlotacaoAr.pdf.jpg
https://repositorio.ufu.br/bitstream/123456789/17398/1/InvestigacaoFlotacaoAr.pdf
https://repositorio.ufu.br/bitstream/123456789/17398/2/InvestigacaoFlotacaoAr.pdf.txt
bitstream.checksum.fl_str_mv ff4cc9abd55863a8227547ce63391a46
69c283f0b94d2016185adc9d7e774cab
44b8aeb02e7adbb4059387900c30d990
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)
repository.mail.fl_str_mv diinf@dirbi.ufu.br
_version_ 1802110478880604160