Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG

Detalhes bibliográficos
Autor(a) principal: Martins, Joaquim Francisco
Data de Publicação: 2005
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFU
Texto Completo: https://repositorio.ufu.br/handle/123456789/29784
http://doi.org/10.14393/ufu.di.2005.51
Resumo: This work describes the development of a multifunctional biotelemetry system capable of detecting and processing ECG, EEG and EMG signals in real time. The main hardware was designed to capture any one of those signals from the same input channel. The user can program the hardware for the desired signal and adjust its gain as necessary. The various features of the system are controlled by a dedicated micro-controller which is also responsible for sending the digital data to a RF transmitter. In order to reduce signal corruption, the data is encrypted in Manchester code prior to transmission. The main soflware runs on a standard IBM-PC microcomputer and is responsible for collecting data from the USB port, graphics and file manipulation. The software was designed to detect the type of signal been transmitted and adjust its gain accordingly. Also, the received data can be processed in the time domain or in the frequency domain. The final prototype is light, fairly small and easy to use. A number of experiments have shown that, even when there are physical barriers between the transmitter and the receiver modules, the transmitted signal shows excellent stability and minimum error.
id UFU_f11532904ad784df88bc68b17ccdd7d2
oai_identifier_str oai:repositorio.ufu.br:123456789/29784
network_acronym_str UFU
network_name_str Repositório Institucional da UFU
repository_id_str
spelling Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMGA multifunctional biotelemetry system for ECG, EEG and EMG signalsBiotelemetriaTransmissão RFECGEMGEEGBiotelemetryRF transmissionCNPQ::ENGENHARIAS::ENGENHARIA ELETRICAProcessamento de sinaisThis work describes the development of a multifunctional biotelemetry system capable of detecting and processing ECG, EEG and EMG signals in real time. The main hardware was designed to capture any one of those signals from the same input channel. The user can program the hardware for the desired signal and adjust its gain as necessary. The various features of the system are controlled by a dedicated micro-controller which is also responsible for sending the digital data to a RF transmitter. In order to reduce signal corruption, the data is encrypted in Manchester code prior to transmission. The main soflware runs on a standard IBM-PC microcomputer and is responsible for collecting data from the USB port, graphics and file manipulation. The software was designed to detect the type of signal been transmitted and adjust its gain accordingly. Also, the received data can be processed in the time domain or in the frequency domain. The final prototype is light, fairly small and easy to use. A number of experiments have shown that, even when there are physical barriers between the transmitter and the receiver modules, the transmitted signal shows excellent stability and minimum error.Dissertação (Mestrado)Este trabalho descreve o desenvolvimento do protótipo de um sistema multifuncional de biotelemetria capaz de detectar e processar sinais ECG, EEG e EMG em tempo real. O sistema de captura e condicionamento de sinais foi preparado para receber em um único canal, sinais ECG, EEG e EMG. O voluntário pode programar tanto o modo de captura para o tipo de sinal quanto o ganho, para efetuar o condicionamento (amplificação e filtragens) necessário. São utilizados microcontroladores específicos com a responsabilidade de controlar e programar as várias características deste sistema. A transmissão dos dados é realizada por rádio frequência com modulação ASK. O protocolo de comunicação desenvolvido baseia-se na codificação Manchester. O aplicativo principal é executado em um computador padrão IBM-PC e é responsável pela captura de dados pela porta USB, visualização em tempo real e processamento de sinais. O software pode detectar automaticamente o tipo de sinal e seu ganho e engloba as diversas funções necessárias para o armazenamento de dados em arquivos e processamento no domínio do tempo e da frequência. O protótipo construído é de fácil utilização, leve e possui dimensões reduzidas. Diversos experimentos demonstraram que, mesmo em situações onde há barreiras físicas entre os módulos de transmissão e de recepção, o sinal transmitido possui excelente confiabilidade.Universidade Federal de UberlândiaBrasilPrograma de Pós-graduação em Engenharia ElétricaSoares, Alcimar Barbosahttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4782970Z5Pereira, Adriano AlvesSantangelo, Erika MattosLima, Luciano VieiraMartins, Joaquim Francisco2020-08-31T14:24:11Z2020-08-31T14:24:11Z2005info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfMARTINS, Joaquim Francisco. Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG. 2005. 121 f. Dissertação (Mestrado em Engenharia Elétrica) - Universidade Federal de Uberlândia, Uberlândia, 2020. DOI http://doi.org/10.14393/ufu.di.2005.51.https://repositorio.ufu.br/handle/123456789/29784http://doi.org/10.14393/ufu.di.2005.51porhttp://creativecommons.org/licenses/by-nc-nd/3.0/us/info:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFUinstname:Universidade Federal de Uberlândia (UFU)instacron:UFU2020-09-01T06:17:37Zoai:repositorio.ufu.br:123456789/29784Repositório InstitucionalONGhttp://repositorio.ufu.br/oai/requestdiinf@dirbi.ufu.bropendoar:2020-09-01T06:17:37Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)false
dc.title.none.fl_str_mv Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG
A multifunctional biotelemetry system for ECG, EEG and EMG signals
title Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG
spellingShingle Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG
Martins, Joaquim Francisco
Biotelemetria
Transmissão RF
ECG
EMG
EEG
Biotelemetry
RF transmission
CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
Processamento de sinais
title_short Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG
title_full Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG
title_fullStr Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG
title_full_unstemmed Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG
title_sort Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG
author Martins, Joaquim Francisco
author_facet Martins, Joaquim Francisco
author_role author
dc.contributor.none.fl_str_mv Soares, Alcimar Barbosa
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4782970Z5
Pereira, Adriano Alves
Santangelo, Erika Mattos
Lima, Luciano Vieira
dc.contributor.author.fl_str_mv Martins, Joaquim Francisco
dc.subject.por.fl_str_mv Biotelemetria
Transmissão RF
ECG
EMG
EEG
Biotelemetry
RF transmission
CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
Processamento de sinais
topic Biotelemetria
Transmissão RF
ECG
EMG
EEG
Biotelemetry
RF transmission
CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
Processamento de sinais
description This work describes the development of a multifunctional biotelemetry system capable of detecting and processing ECG, EEG and EMG signals in real time. The main hardware was designed to capture any one of those signals from the same input channel. The user can program the hardware for the desired signal and adjust its gain as necessary. The various features of the system are controlled by a dedicated micro-controller which is also responsible for sending the digital data to a RF transmitter. In order to reduce signal corruption, the data is encrypted in Manchester code prior to transmission. The main soflware runs on a standard IBM-PC microcomputer and is responsible for collecting data from the USB port, graphics and file manipulation. The software was designed to detect the type of signal been transmitted and adjust its gain accordingly. Also, the received data can be processed in the time domain or in the frequency domain. The final prototype is light, fairly small and easy to use. A number of experiments have shown that, even when there are physical barriers between the transmitter and the receiver modules, the transmitted signal shows excellent stability and minimum error.
publishDate 2005
dc.date.none.fl_str_mv 2005
2020-08-31T14:24:11Z
2020-08-31T14:24:11Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv MARTINS, Joaquim Francisco. Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG. 2005. 121 f. Dissertação (Mestrado em Engenharia Elétrica) - Universidade Federal de Uberlândia, Uberlândia, 2020. DOI http://doi.org/10.14393/ufu.di.2005.51.
https://repositorio.ufu.br/handle/123456789/29784
http://doi.org/10.14393/ufu.di.2005.51
identifier_str_mv MARTINS, Joaquim Francisco. Um sistema de biotelemetria multifuncional para sinais ECG, EEG e EMG. 2005. 121 f. Dissertação (Mestrado em Engenharia Elétrica) - Universidade Federal de Uberlândia, Uberlândia, 2020. DOI http://doi.org/10.14393/ufu.di.2005.51.
url https://repositorio.ufu.br/handle/123456789/29784
http://doi.org/10.14393/ufu.di.2005.51
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/3.0/us/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/3.0/us/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Uberlândia
Brasil
Programa de Pós-graduação em Engenharia Elétrica
publisher.none.fl_str_mv Universidade Federal de Uberlândia
Brasil
Programa de Pós-graduação em Engenharia Elétrica
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFU
instname:Universidade Federal de Uberlândia (UFU)
instacron:UFU
instname_str Universidade Federal de Uberlândia (UFU)
instacron_str UFU
institution UFU
reponame_str Repositório Institucional da UFU
collection Repositório Institucional da UFU
repository.name.fl_str_mv Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)
repository.mail.fl_str_mv diinf@dirbi.ufu.br
_version_ 1813711601892589568