Avaliação da medida de tenacidade do concreto reforçado com fibras de aço
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFU |
Texto Completo: | https://repositorio.ufu.br/handle/123456789/14208 https://doi.org/10.14393/ufu.di.2014.331 |
Resumo: | In the concrete might occur cracks, due to the combination of residual stresses, cure or hydration, fluency effects, retraction and temperature effect. The objetive of incorporating steel fibers to concrete is to control the micro-cracking during aplication of loads and also improve the mechanical and residual resistance to fracturing properties . The toughness of steel fiber reinforced concrete is a fundamental property to control cracking and is determinated by flexural bending test of prismatic beams. The advantages to use SFRC in the civil construction are: better cavitation resistance, improves the strength impact plus the shock thermal and increase the ductility by delaying the crack propagation in the concrete structural elements that is subjected to the tension or tension by flexural. This study, examines experimentally the mechanicals behavior of prismatic specimens of SFRC s toughness, according to the international recommendations of ASTM C1609 (2010), EN 14651 (2007) e JSCE-SF4 (1984). On next phase, the research sought to evaluate the influence of compressive strength and the fiber rate s behavior. The experimental program consisted in two matrices of 30 MPa and 40 MPa with two dosages of fibers corresponding to 60 kg/m³ and 30 kg/m³ (0,77 % and 0,38 % in volume) formed four composite of fibers. 64 prismatic specimens were cast to evaluate the tenacity and 132 cylindrical specimens to characterize the SFRC through the compression tests, modulus of elasticity and tensile by diametric compression (Brazilian test). In relation to the method of tests, the result shows that the increasing toughness of SFRC was higher when the fiber content increased the composite compared to the change in compressive strength. The EN 14651 that uses notched specimens, it is interesting method to determine the toughness of steel fiber reinforced concrete, because the method obtained lower coefficient of variation for toughness values and the crack it always propagates in the plane of the notch. |
id |
UFU_f642f40d0adab38a01af016e9e402740 |
---|---|
oai_identifier_str |
oai:repositorio.ufu.br:123456789/14208 |
network_acronym_str |
UFU |
network_name_str |
Repositório Institucional da UFU |
repository_id_str |
|
spelling |
Avaliação da medida de tenacidade do concreto reforçado com fibras de açoEvaluation of toughness measurement on steel fibre reinforced concreteCompósitoFibras de AçoCRFATenacidadeConcreto armadoCompositeSteel FibersSFRCToughnessCNPQ::ENGENHARIAS::ENGENHARIA CIVILIn the concrete might occur cracks, due to the combination of residual stresses, cure or hydration, fluency effects, retraction and temperature effect. The objetive of incorporating steel fibers to concrete is to control the micro-cracking during aplication of loads and also improve the mechanical and residual resistance to fracturing properties . The toughness of steel fiber reinforced concrete is a fundamental property to control cracking and is determinated by flexural bending test of prismatic beams. The advantages to use SFRC in the civil construction are: better cavitation resistance, improves the strength impact plus the shock thermal and increase the ductility by delaying the crack propagation in the concrete structural elements that is subjected to the tension or tension by flexural. This study, examines experimentally the mechanicals behavior of prismatic specimens of SFRC s toughness, according to the international recommendations of ASTM C1609 (2010), EN 14651 (2007) e JSCE-SF4 (1984). On next phase, the research sought to evaluate the influence of compressive strength and the fiber rate s behavior. The experimental program consisted in two matrices of 30 MPa and 40 MPa with two dosages of fibers corresponding to 60 kg/m³ and 30 kg/m³ (0,77 % and 0,38 % in volume) formed four composite of fibers. 64 prismatic specimens were cast to evaluate the tenacity and 132 cylindrical specimens to characterize the SFRC through the compression tests, modulus of elasticity and tensile by diametric compression (Brazilian test). In relation to the method of tests, the result shows that the increasing toughness of SFRC was higher when the fiber content increased the composite compared to the change in compressive strength. The EN 14651 that uses notched specimens, it is interesting method to determine the toughness of steel fiber reinforced concrete, because the method obtained lower coefficient of variation for toughness values and the crack it always propagates in the plane of the notch.Mestre em Engenharia CivilNo concreto, a fissuração poder ocorrer devido à combinação das tensões residuais em razão da cura ou hidratação, efeitos de fluência, retração e efeito da temperatura. O objetivo de incorporar as fibras de aço ao concreto é controlar a microfissuração durante o carregamento e também melhorar as propriedades mecânicas e de resistências residuais ao fraturamento. A tenacidade do concreto reforçado com fibras de aço (CRFA) é uma propriedade fundamental para controle de fissuração e é determinada com o ensaio de tenacidade à flexão de vigas prismáticas. As vantagens de se utilizar o CRFA na construção civil são: maior resistência à cavitação, melhoria da resistência ao impacto e ao choque térmico e aumento da ductilidade por atrasar a propagação da fissura nos elementos estruturais do concreto submetido à tração ou à tração na flexão. Este estudo analisa os resultados da tenacidade do CRFA, obtidos experimentalmente em corpos de prova prismáticos conforme as recomendações internacionais da ASTM C1609 (2010), EN 14651 (2007) e JSCE-SF4 (1984). Em segundo momento buscou-se avaliar a influência da resistência à compressão e o teor de fibra neste comportamento. O programa experimental consistiu em duas matrizes com fck de 30 MPa e 40 MPa e duas dosagens de fibras correspondente a 60 kg/m³ e 30 kg/m³ (0,77% e 0,38% em volume), formando quatro compósitos. Foram moldados 64 corpos de prova prismáticos para avaliar a medida de tenacidade e 132 corpos de prova cilíndricos para caracterizar o CRFA através dos ensaios de compressão, módulo de elasticidade e tração por compressão diametral. Em relação aos métodos de ensaio, os resultados indicam que o aumento de tenacidade do CRFA foi maior quando se aumentou o teor de fibra no compósito, se comparado à alteração na resistência à compressão. O método EN 14651, que utiliza corpos de prova com entalhe, é um método interessante para determinação da tenacidade de concreto reforçado com fibras de aço, pois o método obteve menor coeficiente de variação dos valores de tenacidade e a fissura sempre se propaga no plano do entalhe.Universidade Federal de UberlândiaBRPrograma de Pós-graduação em Engenharia CivilEngenhariasUFUSantos, Antonio Carlos doshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4703517H6Silva, Turibio José dahttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4798494E6Souza, Rafael Alves dehttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701963A0Arif, Mohammed Adel2016-06-22T18:37:28Z2014-12-102016-06-22T18:37:28Z2014-06-09info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfapplication/pdfARIF, Mohammed Adel. Evaluation of toughness measurement on steel fibre reinforced concrete. 2014. 177 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2014. DOI https://doi.org/10.14393/ufu.di.2014.331https://repositorio.ufu.br/handle/123456789/14208https://doi.org/10.14393/ufu.di.2014.331porinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFUinstname:Universidade Federal de Uberlândia (UFU)instacron:UFU2021-10-14T15:39:11Zoai:repositorio.ufu.br:123456789/14208Repositório InstitucionalONGhttp://repositorio.ufu.br/oai/requestdiinf@dirbi.ufu.bropendoar:2021-10-14T15:39:11Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)false |
dc.title.none.fl_str_mv |
Avaliação da medida de tenacidade do concreto reforçado com fibras de aço Evaluation of toughness measurement on steel fibre reinforced concrete |
title |
Avaliação da medida de tenacidade do concreto reforçado com fibras de aço |
spellingShingle |
Avaliação da medida de tenacidade do concreto reforçado com fibras de aço Arif, Mohammed Adel Compósito Fibras de Aço CRFA Tenacidade Concreto armado Composite Steel Fibers SFRC Toughness CNPQ::ENGENHARIAS::ENGENHARIA CIVIL |
title_short |
Avaliação da medida de tenacidade do concreto reforçado com fibras de aço |
title_full |
Avaliação da medida de tenacidade do concreto reforçado com fibras de aço |
title_fullStr |
Avaliação da medida de tenacidade do concreto reforçado com fibras de aço |
title_full_unstemmed |
Avaliação da medida de tenacidade do concreto reforçado com fibras de aço |
title_sort |
Avaliação da medida de tenacidade do concreto reforçado com fibras de aço |
author |
Arif, Mohammed Adel |
author_facet |
Arif, Mohammed Adel |
author_role |
author |
dc.contributor.none.fl_str_mv |
Santos, Antonio Carlos dos http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4703517H6 Silva, Turibio José da http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4798494E6 Souza, Rafael Alves de http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701963A0 |
dc.contributor.author.fl_str_mv |
Arif, Mohammed Adel |
dc.subject.por.fl_str_mv |
Compósito Fibras de Aço CRFA Tenacidade Concreto armado Composite Steel Fibers SFRC Toughness CNPQ::ENGENHARIAS::ENGENHARIA CIVIL |
topic |
Compósito Fibras de Aço CRFA Tenacidade Concreto armado Composite Steel Fibers SFRC Toughness CNPQ::ENGENHARIAS::ENGENHARIA CIVIL |
description |
In the concrete might occur cracks, due to the combination of residual stresses, cure or hydration, fluency effects, retraction and temperature effect. The objetive of incorporating steel fibers to concrete is to control the micro-cracking during aplication of loads and also improve the mechanical and residual resistance to fracturing properties . The toughness of steel fiber reinforced concrete is a fundamental property to control cracking and is determinated by flexural bending test of prismatic beams. The advantages to use SFRC in the civil construction are: better cavitation resistance, improves the strength impact plus the shock thermal and increase the ductility by delaying the crack propagation in the concrete structural elements that is subjected to the tension or tension by flexural. This study, examines experimentally the mechanicals behavior of prismatic specimens of SFRC s toughness, according to the international recommendations of ASTM C1609 (2010), EN 14651 (2007) e JSCE-SF4 (1984). On next phase, the research sought to evaluate the influence of compressive strength and the fiber rate s behavior. The experimental program consisted in two matrices of 30 MPa and 40 MPa with two dosages of fibers corresponding to 60 kg/m³ and 30 kg/m³ (0,77 % and 0,38 % in volume) formed four composite of fibers. 64 prismatic specimens were cast to evaluate the tenacity and 132 cylindrical specimens to characterize the SFRC through the compression tests, modulus of elasticity and tensile by diametric compression (Brazilian test). In relation to the method of tests, the result shows that the increasing toughness of SFRC was higher when the fiber content increased the composite compared to the change in compressive strength. The EN 14651 that uses notched specimens, it is interesting method to determine the toughness of steel fiber reinforced concrete, because the method obtained lower coefficient of variation for toughness values and the crack it always propagates in the plane of the notch. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-12-10 2014-06-09 2016-06-22T18:37:28Z 2016-06-22T18:37:28Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
ARIF, Mohammed Adel. Evaluation of toughness measurement on steel fibre reinforced concrete. 2014. 177 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2014. DOI https://doi.org/10.14393/ufu.di.2014.331 https://repositorio.ufu.br/handle/123456789/14208 https://doi.org/10.14393/ufu.di.2014.331 |
identifier_str_mv |
ARIF, Mohammed Adel. Evaluation of toughness measurement on steel fibre reinforced concrete. 2014. 177 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2014. DOI https://doi.org/10.14393/ufu.di.2014.331 |
url |
https://repositorio.ufu.br/handle/123456789/14208 https://doi.org/10.14393/ufu.di.2014.331 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Uberlândia BR Programa de Pós-graduação em Engenharia Civil Engenharias UFU |
publisher.none.fl_str_mv |
Universidade Federal de Uberlândia BR Programa de Pós-graduação em Engenharia Civil Engenharias UFU |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFU instname:Universidade Federal de Uberlândia (UFU) instacron:UFU |
instname_str |
Universidade Federal de Uberlândia (UFU) |
instacron_str |
UFU |
institution |
UFU |
reponame_str |
Repositório Institucional da UFU |
collection |
Repositório Institucional da UFU |
repository.name.fl_str_mv |
Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU) |
repository.mail.fl_str_mv |
diinf@dirbi.ufu.br |
_version_ |
1813711307945279488 |