Avaliação da medida de tenacidade do concreto reforçado com fibras de aço

Detalhes bibliográficos
Autor(a) principal: Arif, Mohammed Adel
Data de Publicação: 2014
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFU
Texto Completo: https://repositorio.ufu.br/handle/123456789/14208
https://doi.org/10.14393/ufu.di.2014.331
Resumo: In the concrete might occur cracks, due to the combination of residual stresses, cure or hydration, fluency effects, retraction and temperature effect. The objetive of incorporating steel fibers to concrete is to control the micro-cracking during aplication of loads and also improve the mechanical and residual resistance to fracturing properties . The toughness of steel fiber reinforced concrete is a fundamental property to control cracking and is determinated by flexural bending test of prismatic beams. The advantages to use SFRC in the civil construction are: better cavitation resistance, improves the strength impact plus the shock thermal and increase the ductility by delaying the crack propagation in the concrete structural elements that is subjected to the tension or tension by flexural. This study, examines experimentally the mechanicals behavior of prismatic specimens of SFRC s toughness, according to the international recommendations of ASTM C1609 (2010), EN 14651 (2007) e JSCE-SF4 (1984). On next phase, the research sought to evaluate the influence of compressive strength and the fiber rate s behavior. The experimental program consisted in two matrices of 30 MPa and 40 MPa with two dosages of fibers corresponding to 60 kg/m³ and 30 kg/m³ (0,77 % and 0,38 % in volume) formed four composite of fibers. 64 prismatic specimens were cast to evaluate the tenacity and 132 cylindrical specimens to characterize the SFRC through the compression tests, modulus of elasticity and tensile by diametric compression (Brazilian test). In relation to the method of tests, the result shows that the increasing toughness of SFRC was higher when the fiber content increased the composite compared to the change in compressive strength. The EN 14651 that uses notched specimens, it is interesting method to determine the toughness of steel fiber reinforced concrete, because the method obtained lower coefficient of variation for toughness values and the crack it always propagates in the plane of the notch.
id UFU_f642f40d0adab38a01af016e9e402740
oai_identifier_str oai:repositorio.ufu.br:123456789/14208
network_acronym_str UFU
network_name_str Repositório Institucional da UFU
repository_id_str
spelling 2016-06-22T18:37:28Z2014-12-102016-06-22T18:37:28Z2014-06-09ARIF, Mohammed Adel. Evaluation of toughness measurement on steel fibre reinforced concrete. 2014. 177 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2014. DOI https://doi.org/10.14393/ufu.di.2014.331https://repositorio.ufu.br/handle/123456789/14208https://doi.org/10.14393/ufu.di.2014.331In the concrete might occur cracks, due to the combination of residual stresses, cure or hydration, fluency effects, retraction and temperature effect. The objetive of incorporating steel fibers to concrete is to control the micro-cracking during aplication of loads and also improve the mechanical and residual resistance to fracturing properties . The toughness of steel fiber reinforced concrete is a fundamental property to control cracking and is determinated by flexural bending test of prismatic beams. The advantages to use SFRC in the civil construction are: better cavitation resistance, improves the strength impact plus the shock thermal and increase the ductility by delaying the crack propagation in the concrete structural elements that is subjected to the tension or tension by flexural. This study, examines experimentally the mechanicals behavior of prismatic specimens of SFRC s toughness, according to the international recommendations of ASTM C1609 (2010), EN 14651 (2007) e JSCE-SF4 (1984). On next phase, the research sought to evaluate the influence of compressive strength and the fiber rate s behavior. The experimental program consisted in two matrices of 30 MPa and 40 MPa with two dosages of fibers corresponding to 60 kg/m³ and 30 kg/m³ (0,77 % and 0,38 % in volume) formed four composite of fibers. 64 prismatic specimens were cast to evaluate the tenacity and 132 cylindrical specimens to characterize the SFRC through the compression tests, modulus of elasticity and tensile by diametric compression (Brazilian test). In relation to the method of tests, the result shows that the increasing toughness of SFRC was higher when the fiber content increased the composite compared to the change in compressive strength. The EN 14651 that uses notched specimens, it is interesting method to determine the toughness of steel fiber reinforced concrete, because the method obtained lower coefficient of variation for toughness values and the crack it always propagates in the plane of the notch.No concreto, a fissuração poder ocorrer devido à combinação das tensões residuais em razão da cura ou hidratação, efeitos de fluência, retração e efeito da temperatura. O objetivo de incorporar as fibras de aço ao concreto é controlar a microfissuração durante o carregamento e também melhorar as propriedades mecânicas e de resistências residuais ao fraturamento. A tenacidade do concreto reforçado com fibras de aço (CRFA) é uma propriedade fundamental para controle de fissuração e é determinada com o ensaio de tenacidade à flexão de vigas prismáticas. As vantagens de se utilizar o CRFA na construção civil são: maior resistência à cavitação, melhoria da resistência ao impacto e ao choque térmico e aumento da ductilidade por atrasar a propagação da fissura nos elementos estruturais do concreto submetido à tração ou à tração na flexão. Este estudo analisa os resultados da tenacidade do CRFA, obtidos experimentalmente em corpos de prova prismáticos conforme as recomendações internacionais da ASTM C1609 (2010), EN 14651 (2007) e JSCE-SF4 (1984). Em segundo momento buscou-se avaliar a influência da resistência à compressão e o teor de fibra neste comportamento. O programa experimental consistiu em duas matrizes com fck de 30 MPa e 40 MPa e duas dosagens de fibras correspondente a 60 kg/m³ e 30 kg/m³ (0,77% e 0,38% em volume), formando quatro compósitos. Foram moldados 64 corpos de prova prismáticos para avaliar a medida de tenacidade e 132 corpos de prova cilíndricos para caracterizar o CRFA através dos ensaios de compressão, módulo de elasticidade e tração por compressão diametral. Em relação aos métodos de ensaio, os resultados indicam que o aumento de tenacidade do CRFA foi maior quando se aumentou o teor de fibra no compósito, se comparado à alteração na resistência à compressão. O método EN 14651, que utiliza corpos de prova com entalhe, é um método interessante para determinação da tenacidade de concreto reforçado com fibras de aço, pois o método obteve menor coeficiente de variação dos valores de tenacidade e a fissura sempre se propaga no plano do entalhe.Mestre em Engenharia Civilapplication/pdfporUniversidade Federal de UberlândiaPrograma de Pós-graduação em Engenharia CivilUFUBREngenhariasCompósitoFibras de AçoCRFATenacidadeConcreto armadoCompositeSteel FibersSFRCToughnessCNPQ::ENGENHARIAS::ENGENHARIA CIVILAvaliação da medida de tenacidade do concreto reforçado com fibras de açoEvaluation of toughness measurement on steel fibre reinforced concreteinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisSantos, Antonio Carlos doshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4703517H6Silva, Turibio José dahttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4798494E6Souza, Rafael Alves dehttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701963A0http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4347938T9Arif, Mohammed Adel817543454760f38e-67c9-4f29-9dee-77c4e5a21ac4info:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFUinstname:Universidade Federal de Uberlândia (UFU)instacron:UFUTHUMBNAILAvaliacaoMedidaTenacidade.pdf.jpgAvaliacaoMedidaTenacidade.pdf.jpgGenerated Thumbnailimage/jpeg1566https://repositorio.ufu.br/bitstream/123456789/14208/3/AvaliacaoMedidaTenacidade.pdf.jpg9d485e3dfeb0ae4052ec02d8b3c71884MD53ORIGINALAvaliacaoMedidaTenacidade.pdfapplication/pdf8872464https://repositorio.ufu.br/bitstream/123456789/14208/1/AvaliacaoMedidaTenacidade.pdf3bfeb62bea2fed595bd5553a0e541d00MD51TEXTAvaliacaoMedidaTenacidade.pdf.txtAvaliacaoMedidaTenacidade.pdf.txtExtracted texttext/plain288524https://repositorio.ufu.br/bitstream/123456789/14208/2/AvaliacaoMedidaTenacidade.pdf.txt6a1b6bd6ed13d30a901808624d52e527MD52123456789/142082021-10-14 12:39:11.197oai:repositorio.ufu.br:123456789/14208Repositório InstitucionalONGhttp://repositorio.ufu.br/oai/requestdiinf@dirbi.ufu.bropendoar:2024-04-26T14:50:09.697995Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)false
dc.title.por.fl_str_mv Avaliação da medida de tenacidade do concreto reforçado com fibras de aço
dc.title.alternative.eng.fl_str_mv Evaluation of toughness measurement on steel fibre reinforced concrete
title Avaliação da medida de tenacidade do concreto reforçado com fibras de aço
spellingShingle Avaliação da medida de tenacidade do concreto reforçado com fibras de aço
Arif, Mohammed Adel
Compósito
Fibras de Aço
CRFA
Tenacidade
Concreto armado
Composite
Steel Fibers
SFRC
Toughness
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
title_short Avaliação da medida de tenacidade do concreto reforçado com fibras de aço
title_full Avaliação da medida de tenacidade do concreto reforçado com fibras de aço
title_fullStr Avaliação da medida de tenacidade do concreto reforçado com fibras de aço
title_full_unstemmed Avaliação da medida de tenacidade do concreto reforçado com fibras de aço
title_sort Avaliação da medida de tenacidade do concreto reforçado com fibras de aço
author Arif, Mohammed Adel
author_facet Arif, Mohammed Adel
author_role author
dc.contributor.advisor1.fl_str_mv Santos, Antonio Carlos dos
dc.contributor.advisor1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4703517H6
dc.contributor.referee1.fl_str_mv Silva, Turibio José da
dc.contributor.referee1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4798494E6
dc.contributor.referee2.fl_str_mv Souza, Rafael Alves de
dc.contributor.referee2Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701963A0
dc.contributor.authorLattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4347938T9
dc.contributor.author.fl_str_mv Arif, Mohammed Adel
contributor_str_mv Santos, Antonio Carlos dos
Silva, Turibio José da
Souza, Rafael Alves de
dc.subject.por.fl_str_mv Compósito
Fibras de Aço
CRFA
Tenacidade
Concreto armado
topic Compósito
Fibras de Aço
CRFA
Tenacidade
Concreto armado
Composite
Steel Fibers
SFRC
Toughness
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
dc.subject.eng.fl_str_mv Composite
Steel Fibers
SFRC
Toughness
dc.subject.cnpq.fl_str_mv CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
description In the concrete might occur cracks, due to the combination of residual stresses, cure or hydration, fluency effects, retraction and temperature effect. The objetive of incorporating steel fibers to concrete is to control the micro-cracking during aplication of loads and also improve the mechanical and residual resistance to fracturing properties . The toughness of steel fiber reinforced concrete is a fundamental property to control cracking and is determinated by flexural bending test of prismatic beams. The advantages to use SFRC in the civil construction are: better cavitation resistance, improves the strength impact plus the shock thermal and increase the ductility by delaying the crack propagation in the concrete structural elements that is subjected to the tension or tension by flexural. This study, examines experimentally the mechanicals behavior of prismatic specimens of SFRC s toughness, according to the international recommendations of ASTM C1609 (2010), EN 14651 (2007) e JSCE-SF4 (1984). On next phase, the research sought to evaluate the influence of compressive strength and the fiber rate s behavior. The experimental program consisted in two matrices of 30 MPa and 40 MPa with two dosages of fibers corresponding to 60 kg/m³ and 30 kg/m³ (0,77 % and 0,38 % in volume) formed four composite of fibers. 64 prismatic specimens were cast to evaluate the tenacity and 132 cylindrical specimens to characterize the SFRC through the compression tests, modulus of elasticity and tensile by diametric compression (Brazilian test). In relation to the method of tests, the result shows that the increasing toughness of SFRC was higher when the fiber content increased the composite compared to the change in compressive strength. The EN 14651 that uses notched specimens, it is interesting method to determine the toughness of steel fiber reinforced concrete, because the method obtained lower coefficient of variation for toughness values and the crack it always propagates in the plane of the notch.
publishDate 2014
dc.date.available.fl_str_mv 2014-12-10
2016-06-22T18:37:28Z
dc.date.issued.fl_str_mv 2014-06-09
dc.date.accessioned.fl_str_mv 2016-06-22T18:37:28Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv ARIF, Mohammed Adel. Evaluation of toughness measurement on steel fibre reinforced concrete. 2014. 177 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2014. DOI https://doi.org/10.14393/ufu.di.2014.331
dc.identifier.uri.fl_str_mv https://repositorio.ufu.br/handle/123456789/14208
dc.identifier.doi.por.fl_str_mv https://doi.org/10.14393/ufu.di.2014.331
identifier_str_mv ARIF, Mohammed Adel. Evaluation of toughness measurement on steel fibre reinforced concrete. 2014. 177 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Uberlândia, Uberlândia, 2014. DOI https://doi.org/10.14393/ufu.di.2014.331
url https://repositorio.ufu.br/handle/123456789/14208
https://doi.org/10.14393/ufu.di.2014.331
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Uberlândia
dc.publisher.program.fl_str_mv Programa de Pós-graduação em Engenharia Civil
dc.publisher.initials.fl_str_mv UFU
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Engenharias
publisher.none.fl_str_mv Universidade Federal de Uberlândia
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFU
instname:Universidade Federal de Uberlândia (UFU)
instacron:UFU
instname_str Universidade Federal de Uberlândia (UFU)
instacron_str UFU
institution UFU
reponame_str Repositório Institucional da UFU
collection Repositório Institucional da UFU
bitstream.url.fl_str_mv https://repositorio.ufu.br/bitstream/123456789/14208/3/AvaliacaoMedidaTenacidade.pdf.jpg
https://repositorio.ufu.br/bitstream/123456789/14208/1/AvaliacaoMedidaTenacidade.pdf
https://repositorio.ufu.br/bitstream/123456789/14208/2/AvaliacaoMedidaTenacidade.pdf.txt
bitstream.checksum.fl_str_mv 9d485e3dfeb0ae4052ec02d8b3c71884
3bfeb62bea2fed595bd5553a0e541d00
6a1b6bd6ed13d30a901808624d52e527
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFU - Universidade Federal de Uberlândia (UFU)
repository.mail.fl_str_mv diinf@dirbi.ufu.br
_version_ 1797425437708648448