Effect of chitosan–tungsten composite coating obtained by electrophoretic deposition on the corrosion resistance of Ni–Ti alloy in physiological medium
Autor(a) principal: | |
---|---|
Data de Publicação: | 2023 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista de Engenharia Química e Química |
Texto Completo: | https://periodicos.ufv.br/jcec/article/view/16237 |
Resumo: | Ni–Ti shape memory alloys (Nitinol) are suitable for biomedical applications such as orthodontic, orthopedic, and cardiovascular implants. However, to avoid local inflammatory processes, efforts are being made to functionalize the surface of the Ni–Ti alloy with bioactive materials. Chitosan-based composite coatings can be applied to improve the properties of Ni–Ti alloys due to their excellent properties, such as low toxicity, biocompatibility, biodegradability, and good film-forming ability. In this work, the chitosan–tungsten composite (Chit–W) was evaluated as a protective coating for Ni–Ti alloy in a physiological medium (Ringer's solution). The results of surface morphology and chemical composition (SEM and EDX) confirmed the formation of the composite coating formed by a chitosan matrix impregnated with tungsten oxide nanoparticles. Corrosion resistance results proved the efficiency of the composite coating, acting as a protective barrier between the surface of the substrate (Ni–Ti) and the corrosive environment. Therefore, the results point to a possible system candidate (Ni–Ti alloy coated with Chit–W composite) suitable for applications in orthopedic implants. |
id |
UFV-4_c9a72f3c2ae0719b1cf577e952b9267c |
---|---|
oai_identifier_str |
oai:ojs.periodicos.ufv.br:article/16237 |
network_acronym_str |
UFV-4 |
network_name_str |
Revista de Engenharia Química e Química |
repository_id_str |
|
spelling |
Effect of chitosan–tungsten composite coating obtained by electrophoretic deposition on the corrosion resistance of Ni–Ti alloy in physiological mediumEfeito do revestimento compósito de Quitosana–tungstênio obtido por deposição eletroforética na resistência à corrosão da liga de Ni–Ti em meio fisiológicoNitinolBiomaterialComposite CoatingNitinol. Biomaterial. Revestimento Compósito.Ni–Ti shape memory alloys (Nitinol) are suitable for biomedical applications such as orthodontic, orthopedic, and cardiovascular implants. However, to avoid local inflammatory processes, efforts are being made to functionalize the surface of the Ni–Ti alloy with bioactive materials. Chitosan-based composite coatings can be applied to improve the properties of Ni–Ti alloys due to their excellent properties, such as low toxicity, biocompatibility, biodegradability, and good film-forming ability. In this work, the chitosan–tungsten composite (Chit–W) was evaluated as a protective coating for Ni–Ti alloy in a physiological medium (Ringer's solution). The results of surface morphology and chemical composition (SEM and EDX) confirmed the formation of the composite coating formed by a chitosan matrix impregnated with tungsten oxide nanoparticles. Corrosion resistance results proved the efficiency of the composite coating, acting as a protective barrier between the surface of the substrate (Ni–Ti) and the corrosive environment. Therefore, the results point to a possible system candidate (Ni–Ti alloy coated with Chit–W composite) suitable for applications in orthopedic implants.As ligas com memória de forma de Ni–Ti (Nitinol) são adequadas para aplicações em biomedicina, como implantes ortodônticos, ortopédicos e cardiovasculares. No entanto, para evitar processos inflamatórios locais, busca-se funcionalizar a superfície na liga de Ni–Ti com materiais bioativos. Revestimentos compósitos à base de quitosana podem ser aplicados para melhorar as propriedades das ligas de Ni–Ti devido às suas excelentes propriedades como, baixa toxicidade, biocompatibilidade, biodegradabilidade e boa capacidade de formação de filme. Neste trabalho, o compósito de quitosana–tungstênio (Quit–W) foi avaliado como revestimento protetor da liga de Ni–Ti em meio fisiológico (solução de Ringer). Os resultados de morfologia superficial e composição química (MEV e EDX) comprovaram a formação do revestimento compósito formado por uma matriz de quitosana impregnada com nanopartículas de óxido de tungstênio. Os resultados de resistência à corrosão comprovaram a eficiência do revestimento compósito para atuar como uma barreira de proteção entre a superfície do substrato (Ni–Ti) e o meio corrosivo. Portanto, os resultados apontam para um possível candidato de sistema (liga de Ni–Ti revestida com o compósito de Quit–W) adequado para aplicações no setor de implantes ortopédicos.Universidade Federal de Viçosa - UFV2023-08-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://periodicos.ufv.br/jcec/article/view/1623710.18540/jcecvl9iss6pp16237-01eThe Journal of Engineering and Exact Sciences; Vol. 9 No. 6 (2023); 16237-01eThe Journal of Engineering and Exact Sciences; Vol. 9 Núm. 6 (2023); 16237-01eThe Journal of Engineering and Exact Sciences; v. 9 n. 6 (2023); 16237-01e2527-1075reponame:Revista de Engenharia Química e Químicainstname:Universidade Federal de Viçosa (UFV)instacron:UFVenghttps://periodicos.ufv.br/jcec/article/view/16237/8081Copyright (c) 2023 The Journal of Engineering and Exact Scienceshttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessOliveira, José Anderson MachadoAraujo, Thales GomesCosta, Josiane DantasAlmeida, Arthur Filgueira deCampos, Ana Regina NascimentoSantana, Renato Alexandre Costa de2024-03-26T17:21:54Zoai:ojs.periodicos.ufv.br:article/16237Revistahttp://www.seer.ufv.br/seer/rbeq2/index.php/req2/indexONGhttps://periodicos.ufv.br/jcec/oaijcec.journal@ufv.br||req2@ufv.br2446-94162446-9416opendoar:2024-03-26T17:21:54Revista de Engenharia Química e Química - Universidade Federal de Viçosa (UFV)false |
dc.title.none.fl_str_mv |
Effect of chitosan–tungsten composite coating obtained by electrophoretic deposition on the corrosion resistance of Ni–Ti alloy in physiological medium Efeito do revestimento compósito de Quitosana–tungstênio obtido por deposição eletroforética na resistência à corrosão da liga de Ni–Ti em meio fisiológico |
title |
Effect of chitosan–tungsten composite coating obtained by electrophoretic deposition on the corrosion resistance of Ni–Ti alloy in physiological medium |
spellingShingle |
Effect of chitosan–tungsten composite coating obtained by electrophoretic deposition on the corrosion resistance of Ni–Ti alloy in physiological medium Oliveira, José Anderson Machado Nitinol Biomaterial Composite Coating Nitinol. Biomaterial. Revestimento Compósito. |
title_short |
Effect of chitosan–tungsten composite coating obtained by electrophoretic deposition on the corrosion resistance of Ni–Ti alloy in physiological medium |
title_full |
Effect of chitosan–tungsten composite coating obtained by electrophoretic deposition on the corrosion resistance of Ni–Ti alloy in physiological medium |
title_fullStr |
Effect of chitosan–tungsten composite coating obtained by electrophoretic deposition on the corrosion resistance of Ni–Ti alloy in physiological medium |
title_full_unstemmed |
Effect of chitosan–tungsten composite coating obtained by electrophoretic deposition on the corrosion resistance of Ni–Ti alloy in physiological medium |
title_sort |
Effect of chitosan–tungsten composite coating obtained by electrophoretic deposition on the corrosion resistance of Ni–Ti alloy in physiological medium |
author |
Oliveira, José Anderson Machado |
author_facet |
Oliveira, José Anderson Machado Araujo, Thales Gomes Costa, Josiane Dantas Almeida, Arthur Filgueira de Campos, Ana Regina Nascimento Santana, Renato Alexandre Costa de |
author_role |
author |
author2 |
Araujo, Thales Gomes Costa, Josiane Dantas Almeida, Arthur Filgueira de Campos, Ana Regina Nascimento Santana, Renato Alexandre Costa de |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Oliveira, José Anderson Machado Araujo, Thales Gomes Costa, Josiane Dantas Almeida, Arthur Filgueira de Campos, Ana Regina Nascimento Santana, Renato Alexandre Costa de |
dc.subject.por.fl_str_mv |
Nitinol Biomaterial Composite Coating Nitinol. Biomaterial. Revestimento Compósito. |
topic |
Nitinol Biomaterial Composite Coating Nitinol. Biomaterial. Revestimento Compósito. |
description |
Ni–Ti shape memory alloys (Nitinol) are suitable for biomedical applications such as orthodontic, orthopedic, and cardiovascular implants. However, to avoid local inflammatory processes, efforts are being made to functionalize the surface of the Ni–Ti alloy with bioactive materials. Chitosan-based composite coatings can be applied to improve the properties of Ni–Ti alloys due to their excellent properties, such as low toxicity, biocompatibility, biodegradability, and good film-forming ability. In this work, the chitosan–tungsten composite (Chit–W) was evaluated as a protective coating for Ni–Ti alloy in a physiological medium (Ringer's solution). The results of surface morphology and chemical composition (SEM and EDX) confirmed the formation of the composite coating formed by a chitosan matrix impregnated with tungsten oxide nanoparticles. Corrosion resistance results proved the efficiency of the composite coating, acting as a protective barrier between the surface of the substrate (Ni–Ti) and the corrosive environment. Therefore, the results point to a possible system candidate (Ni–Ti alloy coated with Chit–W composite) suitable for applications in orthopedic implants. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-08-04 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.ufv.br/jcec/article/view/16237 10.18540/jcecvl9iss6pp16237-01e |
url |
https://periodicos.ufv.br/jcec/article/view/16237 |
identifier_str_mv |
10.18540/jcecvl9iss6pp16237-01e |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://periodicos.ufv.br/jcec/article/view/16237/8081 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2023 The Journal of Engineering and Exact Sciences https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2023 The Journal of Engineering and Exact Sciences https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Viçosa - UFV |
publisher.none.fl_str_mv |
Universidade Federal de Viçosa - UFV |
dc.source.none.fl_str_mv |
The Journal of Engineering and Exact Sciences; Vol. 9 No. 6 (2023); 16237-01e The Journal of Engineering and Exact Sciences; Vol. 9 Núm. 6 (2023); 16237-01e The Journal of Engineering and Exact Sciences; v. 9 n. 6 (2023); 16237-01e 2527-1075 reponame:Revista de Engenharia Química e Química instname:Universidade Federal de Viçosa (UFV) instacron:UFV |
instname_str |
Universidade Federal de Viçosa (UFV) |
instacron_str |
UFV |
institution |
UFV |
reponame_str |
Revista de Engenharia Química e Química |
collection |
Revista de Engenharia Química e Química |
repository.name.fl_str_mv |
Revista de Engenharia Química e Química - Universidade Federal de Viçosa (UFV) |
repository.mail.fl_str_mv |
jcec.journal@ufv.br||req2@ufv.br |
_version_ |
1800211186014224384 |