Analysis of the correlation between polar fitness test® protocol and ergospirometry
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | LOCUS Repositório Institucional da UFV |
Texto Completo: | http://dx.doi.org/10.1590/S1517-86922012000300012 http://www.locus.ufv.br/handle/123456789/16855 |
Resumo: | Esta faltando o DOI ou o link. |
id |
UFV_10e99803b7ad3fd862edcf8a63f54fe6 |
---|---|
oai_identifier_str |
oai:locus.ufv.br:123456789/16855 |
network_acronym_str |
UFV |
network_name_str |
LOCUS Repositório Institucional da UFV |
repository_id_str |
2145 |
spelling |
Analysis of the correlation between polar fitness test® protocol and ergospirometryEfficiencyOxygen consumptionErgospirometerEstimationHeart rateEsta faltando o DOI ou o link.The importance of maximal oxygen consumption (O2máx) measurement is justified by its international acceptance as the best physiological parameter to assess the functional capacity of the cardiorespiratory system in both athletes and non-athletes who physically train in order to achieve better health. To determine the agreement between the Polar Fitness Test® protocols to estimate of O2máx and the maximal exercise test with direct gas measurement. Seventeen active males (22.5 ± 2 years) participated in the study. At rest, the Polar Fitness Test® protocol by direct gas collection under maximum effort on treadmill and the Bruce protocol were applied. Significant difference in the O2máx estimation was observed between methods. The Polar Fitness Test® protocol underestimated O2máx a mean of 15% (CI95%: 24;-53%) when compared to the direct protocol. The values obtained by the Polar Fitness Test® did not correlate well with direct measurement in ergospirometer (r = 0.1). The Polar Fitness Test® protocol is not valid to estimate O2máx in physically active young men.Revista Brasileira de Medicina do Esporte2018-01-26T12:09:12Z2018-01-26T12:09:12Z2012-05info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlepdfapplication/pdf1806-9940http://dx.doi.org/10.1590/S1517-86922012000300012http://www.locus.ufv.br/handle/123456789/16855engv. 18, n. 3, p. 195-197, Mai./Jun. 2012Vianna, Jeferson MacedoMarocolo, MoacirBarbosa Neto, OctávioLauria, André de AssisOrsatti, Fábio LeraMota, Gustavo Ribeiro dainfo:eu-repo/semantics/openAccessreponame:LOCUS Repositório Institucional da UFVinstname:Universidade Federal de Viçosa (UFV)instacron:UFV2024-07-12T07:58:58Zoai:locus.ufv.br:123456789/16855Repositório InstitucionalPUBhttps://www.locus.ufv.br/oai/requestfabiojreis@ufv.bropendoar:21452024-07-12T07:58:58LOCUS Repositório Institucional da UFV - Universidade Federal de Viçosa (UFV)false |
dc.title.none.fl_str_mv |
Analysis of the correlation between polar fitness test® protocol and ergospirometry |
title |
Analysis of the correlation between polar fitness test® protocol and ergospirometry |
spellingShingle |
Analysis of the correlation between polar fitness test® protocol and ergospirometry Vianna, Jeferson Macedo Efficiency Oxygen consumption Ergospirometer Estimation Heart rate |
title_short |
Analysis of the correlation between polar fitness test® protocol and ergospirometry |
title_full |
Analysis of the correlation between polar fitness test® protocol and ergospirometry |
title_fullStr |
Analysis of the correlation between polar fitness test® protocol and ergospirometry |
title_full_unstemmed |
Analysis of the correlation between polar fitness test® protocol and ergospirometry |
title_sort |
Analysis of the correlation between polar fitness test® protocol and ergospirometry |
author |
Vianna, Jeferson Macedo |
author_facet |
Vianna, Jeferson Macedo Marocolo, Moacir Barbosa Neto, Octávio Lauria, André de Assis Orsatti, Fábio Lera Mota, Gustavo Ribeiro da |
author_role |
author |
author2 |
Marocolo, Moacir Barbosa Neto, Octávio Lauria, André de Assis Orsatti, Fábio Lera Mota, Gustavo Ribeiro da |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Vianna, Jeferson Macedo Marocolo, Moacir Barbosa Neto, Octávio Lauria, André de Assis Orsatti, Fábio Lera Mota, Gustavo Ribeiro da |
dc.subject.por.fl_str_mv |
Efficiency Oxygen consumption Ergospirometer Estimation Heart rate |
topic |
Efficiency Oxygen consumption Ergospirometer Estimation Heart rate |
description |
Esta faltando o DOI ou o link. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-05 2018-01-26T12:09:12Z 2018-01-26T12:09:12Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
1806-9940 http://dx.doi.org/10.1590/S1517-86922012000300012 http://www.locus.ufv.br/handle/123456789/16855 |
identifier_str_mv |
1806-9940 |
url |
http://dx.doi.org/10.1590/S1517-86922012000300012 http://www.locus.ufv.br/handle/123456789/16855 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
v. 18, n. 3, p. 195-197, Mai./Jun. 2012 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
pdf application/pdf |
dc.publisher.none.fl_str_mv |
Revista Brasileira de Medicina do Esporte |
publisher.none.fl_str_mv |
Revista Brasileira de Medicina do Esporte |
dc.source.none.fl_str_mv |
reponame:LOCUS Repositório Institucional da UFV instname:Universidade Federal de Viçosa (UFV) instacron:UFV |
instname_str |
Universidade Federal de Viçosa (UFV) |
instacron_str |
UFV |
institution |
UFV |
reponame_str |
LOCUS Repositório Institucional da UFV |
collection |
LOCUS Repositório Institucional da UFV |
repository.name.fl_str_mv |
LOCUS Repositório Institucional da UFV - Universidade Federal de Viçosa (UFV) |
repository.mail.fl_str_mv |
fabiojreis@ufv.br |
_version_ |
1822610680059002880 |