Self-monitoring microbiological criteria for the assessment of hygienic procedures during chicken slaughtering

Detalhes bibliográficos
Autor(a) principal: Dias, M. R
Data de Publicação: 2017
Outros Autores: Dianin, K. C. S, Bersot, L. S, Nero, L. A
Tipo de documento: Artigo
Idioma: eng
Título da fonte: LOCUS Repositório Institucional da UFV
Texto Completo: http://dx.doi.org/10.1590/1806-9061-2016-0381
http://locus.ufv.br//handle/123456789/25768
Resumo: Self-monitoring procedures are adopted by food industries to ensure the quality and safety of final products, considering hygiene and processing criteria. This study aimed to evaluate contamination in chicken processing, considering the microbiological criteria proposed by self-monitoring systems. Environmental samples from reception, slaughtering and processing were collected from three chicken slaughterhouses (Sl1, Sl2, Sl3), and subjected to microbiological analysis to enumerate hygiene indicators microorganisms: mesophilic aerobes, enterobacteriaceae, coliforms and Escherichia coli. The obtained counts were converted to log10, compared by ANOVA (p<0.05) and self-monitoring microbiological criteria for each slaughterhouse were considered. In reception, the mean counts of hygiene indicator microorganisms in Sl3 were significantly higher than mean counts observed in Sl1 and Sl2 (p<0.05). During slaughtering, the chilling was enough to decrease the mean counts of all hygiene indicator microorganisms in Sl1, Sl2 and Sl3 (p<0.05). Based on self-monitoring criteria, in the first stages of slaughtering the facilities presented higher frequencies of chicken carcasses with counts above their respective reference values. Sl02 presented carcasses with higher counts after final washing, resulting in environmental samples with higher counts when compared to Sl1 and Sl3 (p<0.05). Even considering the high counts observed in the initial steps of chicken processing and slaughtering, the results indicated the efficacy of hygienic procedures in providing chicken carcasses and cuts with low microbiological contamination. Self-monitoring criteria supported these results, and the high levels of microbial contamination during the initial steps of slaughtering require subsequent antimicrobial hygienic procedures.
id UFV_75a4f74bd03f43439542380a07f1724d
oai_identifier_str oai:locus.ufv.br:123456789/25768
network_acronym_str UFV
network_name_str LOCUS Repositório Institucional da UFV
repository_id_str 2145
spelling Dias, M. RDianin, K. C. SBersot, L. SNero, L. A2019-06-11T11:53:57Z2019-06-11T11:53:57Z2017-0418069061http://dx.doi.org/10.1590/1806-9061-2016-0381http://locus.ufv.br//handle/123456789/25768Self-monitoring procedures are adopted by food industries to ensure the quality and safety of final products, considering hygiene and processing criteria. This study aimed to evaluate contamination in chicken processing, considering the microbiological criteria proposed by self-monitoring systems. Environmental samples from reception, slaughtering and processing were collected from three chicken slaughterhouses (Sl1, Sl2, Sl3), and subjected to microbiological analysis to enumerate hygiene indicators microorganisms: mesophilic aerobes, enterobacteriaceae, coliforms and Escherichia coli. The obtained counts were converted to log10, compared by ANOVA (p<0.05) and self-monitoring microbiological criteria for each slaughterhouse were considered. In reception, the mean counts of hygiene indicator microorganisms in Sl3 were significantly higher than mean counts observed in Sl1 and Sl2 (p<0.05). During slaughtering, the chilling was enough to decrease the mean counts of all hygiene indicator microorganisms in Sl1, Sl2 and Sl3 (p<0.05). Based on self-monitoring criteria, in the first stages of slaughtering the facilities presented higher frequencies of chicken carcasses with counts above their respective reference values. Sl02 presented carcasses with higher counts after final washing, resulting in environmental samples with higher counts when compared to Sl1 and Sl3 (p<0.05). Even considering the high counts observed in the initial steps of chicken processing and slaughtering, the results indicated the efficacy of hygienic procedures in providing chicken carcasses and cuts with low microbiological contamination. Self-monitoring criteria supported these results, and the high levels of microbial contamination during the initial steps of slaughtering require subsequent antimicrobial hygienic procedures.engBrazilian Journal of Poultry Sciencev. 19, n. 02, p. 317- 324, apr./ jun. 2017ChickenSelf-monitoringHygieneSlaughteringProcessingSelf-monitoring microbiological criteria for the assessment of hygienic procedures during chicken slaughteringinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfinfo:eu-repo/semantics/openAccessreponame:LOCUS Repositório Institucional da UFVinstname:Universidade Federal de Viçosa (UFV)instacron:UFVORIGINALLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://locus.ufv.br//bitstream/123456789/25768/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52123456789/257682019-06-11 09:14:31.439oai:locus.ufv.br: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Repositório InstitucionalPUBhttps://www.locus.ufv.br/oai/requestfabiojreis@ufv.bropendoar:21452019-06-11T12:14:31LOCUS Repositório Institucional da UFV - Universidade Federal de Viçosa (UFV)false
dc.title.pt-BR.fl_str_mv Self-monitoring microbiological criteria for the assessment of hygienic procedures during chicken slaughtering
title Self-monitoring microbiological criteria for the assessment of hygienic procedures during chicken slaughtering
spellingShingle Self-monitoring microbiological criteria for the assessment of hygienic procedures during chicken slaughtering
Dias, M. R
Chicken
Self-monitoring
Hygiene
Slaughtering
Processing
title_short Self-monitoring microbiological criteria for the assessment of hygienic procedures during chicken slaughtering
title_full Self-monitoring microbiological criteria for the assessment of hygienic procedures during chicken slaughtering
title_fullStr Self-monitoring microbiological criteria for the assessment of hygienic procedures during chicken slaughtering
title_full_unstemmed Self-monitoring microbiological criteria for the assessment of hygienic procedures during chicken slaughtering
title_sort Self-monitoring microbiological criteria for the assessment of hygienic procedures during chicken slaughtering
author Dias, M. R
author_facet Dias, M. R
Dianin, K. C. S
Bersot, L. S
Nero, L. A
author_role author
author2 Dianin, K. C. S
Bersot, L. S
Nero, L. A
author2_role author
author
author
dc.contributor.author.fl_str_mv Dias, M. R
Dianin, K. C. S
Bersot, L. S
Nero, L. A
dc.subject.pt-BR.fl_str_mv Chicken
Self-monitoring
Hygiene
Slaughtering
Processing
topic Chicken
Self-monitoring
Hygiene
Slaughtering
Processing
description Self-monitoring procedures are adopted by food industries to ensure the quality and safety of final products, considering hygiene and processing criteria. This study aimed to evaluate contamination in chicken processing, considering the microbiological criteria proposed by self-monitoring systems. Environmental samples from reception, slaughtering and processing were collected from three chicken slaughterhouses (Sl1, Sl2, Sl3), and subjected to microbiological analysis to enumerate hygiene indicators microorganisms: mesophilic aerobes, enterobacteriaceae, coliforms and Escherichia coli. The obtained counts were converted to log10, compared by ANOVA (p<0.05) and self-monitoring microbiological criteria for each slaughterhouse were considered. In reception, the mean counts of hygiene indicator microorganisms in Sl3 were significantly higher than mean counts observed in Sl1 and Sl2 (p<0.05). During slaughtering, the chilling was enough to decrease the mean counts of all hygiene indicator microorganisms in Sl1, Sl2 and Sl3 (p<0.05). Based on self-monitoring criteria, in the first stages of slaughtering the facilities presented higher frequencies of chicken carcasses with counts above their respective reference values. Sl02 presented carcasses with higher counts after final washing, resulting in environmental samples with higher counts when compared to Sl1 and Sl3 (p<0.05). Even considering the high counts observed in the initial steps of chicken processing and slaughtering, the results indicated the efficacy of hygienic procedures in providing chicken carcasses and cuts with low microbiological contamination. Self-monitoring criteria supported these results, and the high levels of microbial contamination during the initial steps of slaughtering require subsequent antimicrobial hygienic procedures.
publishDate 2017
dc.date.issued.fl_str_mv 2017-04
dc.date.accessioned.fl_str_mv 2019-06-11T11:53:57Z
dc.date.available.fl_str_mv 2019-06-11T11:53:57Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/1806-9061-2016-0381
http://locus.ufv.br//handle/123456789/25768
dc.identifier.issn.none.fl_str_mv 18069061
identifier_str_mv 18069061
url http://dx.doi.org/10.1590/1806-9061-2016-0381
http://locus.ufv.br//handle/123456789/25768
dc.language.iso.fl_str_mv eng
language eng
dc.relation.ispartofseries.pt-BR.fl_str_mv v. 19, n. 02, p. 317- 324, apr./ jun. 2017
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Brazilian Journal of Poultry Science
publisher.none.fl_str_mv Brazilian Journal of Poultry Science
dc.source.none.fl_str_mv reponame:LOCUS Repositório Institucional da UFV
instname:Universidade Federal de Viçosa (UFV)
instacron:UFV
instname_str Universidade Federal de Viçosa (UFV)
instacron_str UFV
institution UFV
reponame_str LOCUS Repositório Institucional da UFV
collection LOCUS Repositório Institucional da UFV
bitstream.url.fl_str_mv https://locus.ufv.br//bitstream/123456789/25768/2/license.txt
bitstream.checksum.fl_str_mv 8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv LOCUS Repositório Institucional da UFV - Universidade Federal de Viçosa (UFV)
repository.mail.fl_str_mv fabiojreis@ufv.br
_version_ 1801213120845185024