A novel micellar medium using triblock copolymer for cobalt determination
Autor(a) principal: | |
---|---|
Data de Publicação: | 2005 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | LOCUS Repositório Institucional da UFV |
Texto Completo: | https://doi.org/10.2116/analsci.21.933 http://www.locus.ufv.br/handle/123456789/18732 |
Resumo: | This work proposes a new method for Co(II) determination based on the use of the triblock copolymer as micellar medium instead of chloroform. The proposed strategy is environmental friendly because the copolymer is biodegradable and nontoxic. The method is based on the formation of a cobalt-1-nitroso-2-naphthol complex, in the micellar triblock copolymer compound solution constituted by polyethylene oxide (PEO) and polypropylene oxide (PPO). Experimental conditions such as pH, the molecular weight and the PEO/PPO ratio of triblock copolymer were optimized. Results obtained for cobalt determination in vitamins with this novel method showed excellent agreement with those obtained using atomic absorption spectrometry. The relative standard deviation for a solution containing 0.125 mg L-1 Co was 1.0% (n = 5); the relative error varied from 2.8 to 4.4%; the detection limit was 13.3 µg L-1 and the quantification limit was 44.3 µg L-1. |
id |
UFV_99869ad7daca26107cde5ee2d6f82e2d |
---|---|
oai_identifier_str |
oai:locus.ufv.br:123456789/18732 |
network_acronym_str |
UFV |
network_name_str |
LOCUS Repositório Institucional da UFV |
repository_id_str |
2145 |
spelling |
A novel micellar medium using triblock copolymer for cobalt determinationMicellarDeterminationDetectionThis work proposes a new method for Co(II) determination based on the use of the triblock copolymer as micellar medium instead of chloroform. The proposed strategy is environmental friendly because the copolymer is biodegradable and nontoxic. The method is based on the formation of a cobalt-1-nitroso-2-naphthol complex, in the micellar triblock copolymer compound solution constituted by polyethylene oxide (PEO) and polypropylene oxide (PPO). Experimental conditions such as pH, the molecular weight and the PEO/PPO ratio of triblock copolymer were optimized. Results obtained for cobalt determination in vitamins with this novel method showed excellent agreement with those obtained using atomic absorption spectrometry. The relative standard deviation for a solution containing 0.125 mg L-1 Co was 1.0% (n = 5); the relative error varied from 2.8 to 4.4%; the detection limit was 13.3 µg L-1 and the quantification limit was 44.3 µg L-1.Analytical Sciences2018-04-16T17:53:24Z2018-04-16T17:53:24Z2005-02-21info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlepdfapplication/pdf1348-2246https://doi.org/10.2116/analsci.21.933http://www.locus.ufv.br/handle/123456789/18732engv. 21, n. 8, p. 933-937, agosto 2005Silva, Maria C. H. daSilva, Luis H. M. daPaggioli, Fernanda J.info:eu-repo/semantics/openAccessreponame:LOCUS Repositório Institucional da UFVinstname:Universidade Federal de Viçosa (UFV)instacron:UFV2024-07-12T08:41:14Zoai:locus.ufv.br:123456789/18732Repositório InstitucionalPUBhttps://www.locus.ufv.br/oai/requestfabiojreis@ufv.bropendoar:21452024-07-12T08:41:14LOCUS Repositório Institucional da UFV - Universidade Federal de Viçosa (UFV)false |
dc.title.none.fl_str_mv |
A novel micellar medium using triblock copolymer for cobalt determination |
title |
A novel micellar medium using triblock copolymer for cobalt determination |
spellingShingle |
A novel micellar medium using triblock copolymer for cobalt determination Silva, Maria C. H. da Micellar Determination Detection |
title_short |
A novel micellar medium using triblock copolymer for cobalt determination |
title_full |
A novel micellar medium using triblock copolymer for cobalt determination |
title_fullStr |
A novel micellar medium using triblock copolymer for cobalt determination |
title_full_unstemmed |
A novel micellar medium using triblock copolymer for cobalt determination |
title_sort |
A novel micellar medium using triblock copolymer for cobalt determination |
author |
Silva, Maria C. H. da |
author_facet |
Silva, Maria C. H. da Silva, Luis H. M. da Paggioli, Fernanda J. |
author_role |
author |
author2 |
Silva, Luis H. M. da Paggioli, Fernanda J. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Silva, Maria C. H. da Silva, Luis H. M. da Paggioli, Fernanda J. |
dc.subject.por.fl_str_mv |
Micellar Determination Detection |
topic |
Micellar Determination Detection |
description |
This work proposes a new method for Co(II) determination based on the use of the triblock copolymer as micellar medium instead of chloroform. The proposed strategy is environmental friendly because the copolymer is biodegradable and nontoxic. The method is based on the formation of a cobalt-1-nitroso-2-naphthol complex, in the micellar triblock copolymer compound solution constituted by polyethylene oxide (PEO) and polypropylene oxide (PPO). Experimental conditions such as pH, the molecular weight and the PEO/PPO ratio of triblock copolymer were optimized. Results obtained for cobalt determination in vitamins with this novel method showed excellent agreement with those obtained using atomic absorption spectrometry. The relative standard deviation for a solution containing 0.125 mg L-1 Co was 1.0% (n = 5); the relative error varied from 2.8 to 4.4%; the detection limit was 13.3 µg L-1 and the quantification limit was 44.3 µg L-1. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005-02-21 2018-04-16T17:53:24Z 2018-04-16T17:53:24Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
1348-2246 https://doi.org/10.2116/analsci.21.933 http://www.locus.ufv.br/handle/123456789/18732 |
identifier_str_mv |
1348-2246 |
url |
https://doi.org/10.2116/analsci.21.933 http://www.locus.ufv.br/handle/123456789/18732 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
v. 21, n. 8, p. 933-937, agosto 2005 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
pdf application/pdf |
dc.publisher.none.fl_str_mv |
Analytical Sciences |
publisher.none.fl_str_mv |
Analytical Sciences |
dc.source.none.fl_str_mv |
reponame:LOCUS Repositório Institucional da UFV instname:Universidade Federal de Viçosa (UFV) instacron:UFV |
instname_str |
Universidade Federal de Viçosa (UFV) |
instacron_str |
UFV |
institution |
UFV |
reponame_str |
LOCUS Repositório Institucional da UFV |
collection |
LOCUS Repositório Institucional da UFV |
repository.name.fl_str_mv |
LOCUS Repositório Institucional da UFV - Universidade Federal de Viçosa (UFV) |
repository.mail.fl_str_mv |
fabiojreis@ufv.br |
_version_ |
1817560035288416256 |