Caracterização e alternativas para melhoria operacional da estação de tratamento de efluentes de uma indústria alimentícia
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | LOCUS Repositório Institucional da UFV |
Texto Completo: | http://locus.ufv.br/handle/123456789/3829 |
Resumo: | The Brazilian food industry has presented steady growth and development and is responsible for annual sales of over 350 billion reais. The wide range of food products includes snacks. The wide variety of products implies a variety of effluents of differing qualities. The objective of the present study was to operation of a snack factory wastewater treatment plant (WWTP) that receives two distinct flows, one sanitary and the other originating from weekly equipment cleaning, of a more industrial nature. Samples were collected at four points in the WWTP for physico-chemical and ecotoxicological evaluation. Studies were performed to determine effluent flow rates and their variation over one week[s production and the amount of sodium carbonate that would need to be used to neutralize the effluents at the entrance of the biological treatment, comprised of a septic tank and anaerobic filter. of efficiency in bench scale and characterization of industrial effluents. Laboratory studies were also carried to evaluate the potential for use of a commercial product containing fermentative bacteria for improving COD removal efficiencies. The results revealed the WWTP inefficiency and failure to meet state discharge limits for most parameters. The factory ́s effluents are acutely toxic and at the entrance of the septic tank they are acidic and lack sufficient nutrients to permit biological treatment. A COD removal efficiency of 58% and elimination of acute toxicity was achieved in a 96 hour anaerobic treatment of the sanitary wastewater in the laboratory. When the sanitary wastewater was mixed with the cleaning wastewater, COD removal was only 40% and toxicity was not eliminated. Addition of the commercial did not improve COD removal in either wastewater. |
id |
UFV_a5b8af4598fa849beaca19950e4223ce |
---|---|
oai_identifier_str |
oai:locus.ufv.br:123456789/3829 |
network_acronym_str |
UFV |
network_name_str |
LOCUS Repositório Institucional da UFV |
repository_id_str |
2145 |
spelling |
Landim, João Felipe Carvalhohttp://lattes.cnpq.br/6832139690051429Mounteer, Ann Honorhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4723208Y4Silva, Cláudio Mudadohttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4727931T6Passos, Frederico José Vieirahttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4781218J92015-03-26T13:28:33Z2014-11-262015-03-26T13:28:33Z2014-02-21LANDIM, João Felipe Carvalho. Characterization and alternatives for operational improvement of a food industry wastewater treatment plant. 2014. 68 f. Dissertação (Mestrado em Geotecnia; Saneamento ambiental) - Universidade Federal de Viçosa, Viçosa, 2014.http://locus.ufv.br/handle/123456789/3829The Brazilian food industry has presented steady growth and development and is responsible for annual sales of over 350 billion reais. The wide range of food products includes snacks. The wide variety of products implies a variety of effluents of differing qualities. The objective of the present study was to operation of a snack factory wastewater treatment plant (WWTP) that receives two distinct flows, one sanitary and the other originating from weekly equipment cleaning, of a more industrial nature. Samples were collected at four points in the WWTP for physico-chemical and ecotoxicological evaluation. Studies were performed to determine effluent flow rates and their variation over one week[s production and the amount of sodium carbonate that would need to be used to neutralize the effluents at the entrance of the biological treatment, comprised of a septic tank and anaerobic filter. of efficiency in bench scale and characterization of industrial effluents. Laboratory studies were also carried to evaluate the potential for use of a commercial product containing fermentative bacteria for improving COD removal efficiencies. The results revealed the WWTP inefficiency and failure to meet state discharge limits for most parameters. The factory ́s effluents are acutely toxic and at the entrance of the septic tank they are acidic and lack sufficient nutrients to permit biological treatment. A COD removal efficiency of 58% and elimination of acute toxicity was achieved in a 96 hour anaerobic treatment of the sanitary wastewater in the laboratory. When the sanitary wastewater was mixed with the cleaning wastewater, COD removal was only 40% and toxicity was not eliminated. Addition of the commercial did not improve COD removal in either wastewater.O cenário brasileiro apresenta o crescimento e desenvolvimento da indústria alimentícia, responsável pelo faturamento de mais de 350 bilhões de reais. Dentro da gama de produtos alimentícios encontram-se os salgadinhos tipo snacks . É fato que existe grande diversidade na produção de alimentos, portanto pode-se esperar que o mesmo ocorra com os efluentes líquidos. O presente trabalho teve por objetivo avaliar a operação de uma estação de tratamento de efluentes (ETE) em uma fábrica de snacks que recebe efluentes provenientes de duas correntes distintas, uma predominantemente sanitária, e outra originando da lavagem semanal, com características industriais. Amostras foram coletadas em quatro pontos da ETE da fábrica para caracterização físico-química e ecotoxicológica. Foram feitos estudos na fábrica para determinar a vazão e sua variação ao longo de uma semana de produção e a dose de carbonato de sódio necessária para neutralizar os efluentes na entrada do tratamento biológico, composto de um sistema fossa- filtro. Também foram realizados estudos no laboratório para avaliar o potencial do uso de um produto comercial contendo bactérias fermentativas para aumentar a eficiência de remoção de DQO dos efluentes. Os resultados encontrados apontam para a ineficiência da ETE e não atendimento aos padrões de lançamento de efluentes na legislação mineira. Os efluentes da fábrica são agudamente tóxicos e os que entram no sistema fossa-filtro são ácidos e não contém nutrientes suficientes para permitir o tratamento biológico. No laboratório, o tratamento anaeróbio do efluente sanitário por 96 horas, resultou em remoção de 58% da DQO e eliminação do efeito tóxico agudo. Quando o efluente sanitário foi tratado em conjunto com o efluente da lavagem, a remoção de DQO foi de 40%, e a toxicidade aguda não foi removida. A adição do produto comercial não aumentou a remoção de DQO nos dois efluentes.application/pdfporUniversidade Federal de ViçosaMestrado em Engenharia CivilUFVBRGeotecnia; Saneamento ambientalÁguas residuaisResíduos industriaisEfluentesAnaeróbioSalgadinhoWastewaterIndustrial wasteeffluentsanaerobicSnackCNPQ::ENGENHARIAS::ENGENHARIA SANITARIA::SANEAMENTO AMBIENTALCaracterização e alternativas para melhoria operacional da estação de tratamento de efluentes de uma indústria alimentíciaCharacterization and alternatives for operational improvement of a food industry wastewater treatment plantinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:LOCUS Repositório Institucional da UFVinstname:Universidade Federal de Viçosa (UFV)instacron:UFVORIGINALtexto completo.pdfapplication/pdf1557160https://locus.ufv.br//bitstream/123456789/3829/1/texto%20completo.pdfee45d445a6117bd3a5fbf41e894c2d10MD51TEXTtexto completo.pdf.txttexto completo.pdf.txtExtracted texttext/plain98412https://locus.ufv.br//bitstream/123456789/3829/2/texto%20completo.pdf.txt4905045fadaf28f5db135dadc0917673MD52THUMBNAILtexto completo.pdf.jpgtexto completo.pdf.jpgIM Thumbnailimage/jpeg3700https://locus.ufv.br//bitstream/123456789/3829/3/texto%20completo.pdf.jpg262e55952a91673955dc7d5f55ad65f4MD53123456789/38292016-04-09 23:19:53.209oai:locus.ufv.br:123456789/3829Repositório InstitucionalPUBhttps://www.locus.ufv.br/oai/requestfabiojreis@ufv.bropendoar:21452016-04-10T02:19:53LOCUS Repositório Institucional da UFV - Universidade Federal de Viçosa (UFV)false |
dc.title.por.fl_str_mv |
Caracterização e alternativas para melhoria operacional da estação de tratamento de efluentes de uma indústria alimentícia |
dc.title.alternative.eng.fl_str_mv |
Characterization and alternatives for operational improvement of a food industry wastewater treatment plant |
title |
Caracterização e alternativas para melhoria operacional da estação de tratamento de efluentes de uma indústria alimentícia |
spellingShingle |
Caracterização e alternativas para melhoria operacional da estação de tratamento de efluentes de uma indústria alimentícia Landim, João Felipe Carvalho Águas residuais Resíduos industriais Efluentes Anaeróbio Salgadinho Wastewater Industrial waste effluents anaerobic Snack CNPQ::ENGENHARIAS::ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL |
title_short |
Caracterização e alternativas para melhoria operacional da estação de tratamento de efluentes de uma indústria alimentícia |
title_full |
Caracterização e alternativas para melhoria operacional da estação de tratamento de efluentes de uma indústria alimentícia |
title_fullStr |
Caracterização e alternativas para melhoria operacional da estação de tratamento de efluentes de uma indústria alimentícia |
title_full_unstemmed |
Caracterização e alternativas para melhoria operacional da estação de tratamento de efluentes de uma indústria alimentícia |
title_sort |
Caracterização e alternativas para melhoria operacional da estação de tratamento de efluentes de uma indústria alimentícia |
author |
Landim, João Felipe Carvalho |
author_facet |
Landim, João Felipe Carvalho |
author_role |
author |
dc.contributor.authorLattes.por.fl_str_mv |
http://lattes.cnpq.br/6832139690051429 |
dc.contributor.author.fl_str_mv |
Landim, João Felipe Carvalho |
dc.contributor.advisor1.fl_str_mv |
Mounteer, Ann Honor |
dc.contributor.advisor1Lattes.fl_str_mv |
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4723208Y4 |
dc.contributor.referee1.fl_str_mv |
Silva, Cláudio Mudado |
dc.contributor.referee1Lattes.fl_str_mv |
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4727931T6 |
dc.contributor.referee2.fl_str_mv |
Passos, Frederico José Vieira |
dc.contributor.referee2Lattes.fl_str_mv |
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4781218J9 |
contributor_str_mv |
Mounteer, Ann Honor Silva, Cláudio Mudado Passos, Frederico José Vieira |
dc.subject.por.fl_str_mv |
Águas residuais Resíduos industriais Efluentes Anaeróbio Salgadinho |
topic |
Águas residuais Resíduos industriais Efluentes Anaeróbio Salgadinho Wastewater Industrial waste effluents anaerobic Snack CNPQ::ENGENHARIAS::ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL |
dc.subject.eng.fl_str_mv |
Wastewater Industrial waste effluents anaerobic Snack |
dc.subject.cnpq.fl_str_mv |
CNPQ::ENGENHARIAS::ENGENHARIA SANITARIA::SANEAMENTO AMBIENTAL |
description |
The Brazilian food industry has presented steady growth and development and is responsible for annual sales of over 350 billion reais. The wide range of food products includes snacks. The wide variety of products implies a variety of effluents of differing qualities. The objective of the present study was to operation of a snack factory wastewater treatment plant (WWTP) that receives two distinct flows, one sanitary and the other originating from weekly equipment cleaning, of a more industrial nature. Samples were collected at four points in the WWTP for physico-chemical and ecotoxicological evaluation. Studies were performed to determine effluent flow rates and their variation over one week[s production and the amount of sodium carbonate that would need to be used to neutralize the effluents at the entrance of the biological treatment, comprised of a septic tank and anaerobic filter. of efficiency in bench scale and characterization of industrial effluents. Laboratory studies were also carried to evaluate the potential for use of a commercial product containing fermentative bacteria for improving COD removal efficiencies. The results revealed the WWTP inefficiency and failure to meet state discharge limits for most parameters. The factory ́s effluents are acutely toxic and at the entrance of the septic tank they are acidic and lack sufficient nutrients to permit biological treatment. A COD removal efficiency of 58% and elimination of acute toxicity was achieved in a 96 hour anaerobic treatment of the sanitary wastewater in the laboratory. When the sanitary wastewater was mixed with the cleaning wastewater, COD removal was only 40% and toxicity was not eliminated. Addition of the commercial did not improve COD removal in either wastewater. |
publishDate |
2014 |
dc.date.available.fl_str_mv |
2014-11-26 2015-03-26T13:28:33Z |
dc.date.issued.fl_str_mv |
2014-02-21 |
dc.date.accessioned.fl_str_mv |
2015-03-26T13:28:33Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
LANDIM, João Felipe Carvalho. Characterization and alternatives for operational improvement of a food industry wastewater treatment plant. 2014. 68 f. Dissertação (Mestrado em Geotecnia; Saneamento ambiental) - Universidade Federal de Viçosa, Viçosa, 2014. |
dc.identifier.uri.fl_str_mv |
http://locus.ufv.br/handle/123456789/3829 |
identifier_str_mv |
LANDIM, João Felipe Carvalho. Characterization and alternatives for operational improvement of a food industry wastewater treatment plant. 2014. 68 f. Dissertação (Mestrado em Geotecnia; Saneamento ambiental) - Universidade Federal de Viçosa, Viçosa, 2014. |
url |
http://locus.ufv.br/handle/123456789/3829 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Viçosa |
dc.publisher.program.fl_str_mv |
Mestrado em Engenharia Civil |
dc.publisher.initials.fl_str_mv |
UFV |
dc.publisher.country.fl_str_mv |
BR |
dc.publisher.department.fl_str_mv |
Geotecnia; Saneamento ambiental |
publisher.none.fl_str_mv |
Universidade Federal de Viçosa |
dc.source.none.fl_str_mv |
reponame:LOCUS Repositório Institucional da UFV instname:Universidade Federal de Viçosa (UFV) instacron:UFV |
instname_str |
Universidade Federal de Viçosa (UFV) |
instacron_str |
UFV |
institution |
UFV |
reponame_str |
LOCUS Repositório Institucional da UFV |
collection |
LOCUS Repositório Institucional da UFV |
bitstream.url.fl_str_mv |
https://locus.ufv.br//bitstream/123456789/3829/1/texto%20completo.pdf https://locus.ufv.br//bitstream/123456789/3829/2/texto%20completo.pdf.txt https://locus.ufv.br//bitstream/123456789/3829/3/texto%20completo.pdf.jpg |
bitstream.checksum.fl_str_mv |
ee45d445a6117bd3a5fbf41e894c2d10 4905045fadaf28f5db135dadc0917673 262e55952a91673955dc7d5f55ad65f4 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
LOCUS Repositório Institucional da UFV - Universidade Federal de Viçosa (UFV) |
repository.mail.fl_str_mv |
fabiojreis@ufv.br |
_version_ |
1801213056782434304 |