Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco

Detalhes bibliográficos
Autor(a) principal: Zorzal, Marlei de Fátima Bonella
Data de Publicação: 2007
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UNIGRANRIO
Texto Completo: http://localhost:8080/tede/handle/tede/99
Resumo: Dental Implant treatment planning requires an accurate evaluation of bone site which includes density, width and height as well the relationship with anatomic structures such as maxillary sinus and mandibular canal. In order to have precise dental implant treatment it is important to have radiographies exams that would provide diagnosis, good quality images and accuracy to the treatment. The present study aims to evaluate the accuracy of conventional linear tomography and cone beam computerized tomography compared to predetermined and marked points of references in five dry mandibles and maxillas skulls. After all tomography were performed, the dry mandibular and maxilla bones were prepared for measurements thus considered real measurements. Dry bone and conventional linear tomography measurements were performed using the obtained image using the program AutoCAD® while the cone beam computerized tomography measurements were recorded using Dental Slice 2.4.3 software (BIOPARTS - prototipagem biomédica). Regarding, statistical analyses of the results, Wilcoxon non parametric statistic test showed differences between dry bones and cone beam computerized tomography (P<0,0001). There were differences between dry bones and conventional linear tomography (P< 0,0001). In addition, there were differences between cone beam computerized tomography and conventional linear tomography (P< 0,0001). Concerning the preciseness of technique, Mann-Whitney non parametric statistic test demonstrate that both tomography methods presented statistic significant differences, showing P<0,0001. Although, the cone beam computerized tomography presented with lower statistical significant differences.
id UGRI_9df14bad0283252ee2002e79254067de
oai_identifier_str oai:localhost:tede/99
network_acronym_str UGRI
network_name_str Biblioteca Digital de Teses e Dissertações da UNIGRANRIO
repository_id_str
spelling Harari, Nassim DavidCançado, Renata PittellaRaymundo Júnior, RubensReis, Rodrigo Sant'anna Aguiar dosZorzal, Marlei de Fátima Bonella2016-11-11T12:49:00Z2007-04-13ZORZAL, Marlei de Fátima Bonella. Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco. 2007. 146 f. Dissertação (Mestrado em Odontologia) - Universidade do Grande Rio “Prof. José de Souza Herdy", Duque de Caxias.http://localhost:8080/tede/handle/tede/99Dental Implant treatment planning requires an accurate evaluation of bone site which includes density, width and height as well the relationship with anatomic structures such as maxillary sinus and mandibular canal. In order to have precise dental implant treatment it is important to have radiographies exams that would provide diagnosis, good quality images and accuracy to the treatment. The present study aims to evaluate the accuracy of conventional linear tomography and cone beam computerized tomography compared to predetermined and marked points of references in five dry mandibles and maxillas skulls. After all tomography were performed, the dry mandibular and maxilla bones were prepared for measurements thus considered real measurements. Dry bone and conventional linear tomography measurements were performed using the obtained image using the program AutoCAD® while the cone beam computerized tomography measurements were recorded using Dental Slice 2.4.3 software (BIOPARTS - prototipagem biomédica). Regarding, statistical analyses of the results, Wilcoxon non parametric statistic test showed differences between dry bones and cone beam computerized tomography (P<0,0001). There were differences between dry bones and conventional linear tomography (P< 0,0001). In addition, there were differences between cone beam computerized tomography and conventional linear tomography (P< 0,0001). Concerning the preciseness of technique, Mann-Whitney non parametric statistic test demonstrate that both tomography methods presented statistic significant differences, showing P<0,0001. Although, the cone beam computerized tomography presented with lower statistical significant differences.O planejamento do tratamento com implantes requer avaliação da região selecionada quanto à densidade, largura e altura óssea e localização das estruturas anatômicas, como o seio maxilar e canal mandibular. Todos esses aspectos evidenciam a importância de um exame radiográfico para diagnóstico que forneça boas imagens e precisão para o tratamento. Esta pesquisa teve como objetivo avaliar a precisão das tomografias convencional linear e computadorizada de feixe cônico comparadas com pontos de referência predeterminados e marcados em cinco mandíbulas e maxilas de crânios secos. Após a realização das tomografias, os crânios secos foram preparados para a execução das mensurações e estas consideradas medidas reais. As mensurações dos crânios secos e das tomografias convencionais lineares foram feitas por meio da captura das imagens obtidas e da utilização do programa AutoCAD®, enquanto as mensurações das tomografias computadorizadas de feixe cônico foram executadas com auxílio do programa DentalSlice versão 2.4.3. Na análise estatística dos resultados, o teste não-paramétrico de Wilcoxon indicou diferenças entre as medidas obtidas dos crânios secos e as das tomografias computadorizadas de feixe cônico; entre as medidas dos crânios secos e as das tomografias convencionais lineares; e entre as tomografias computadorizadas de feixe cônico e as convencionais lineares, apresentando valor de P<0,0001. Em se tratando da determinação de uma maior precisão de técnica, o teste não-paramétrico de Mann-Whitney evidenciou que os dois métodos apresentaram diferenças estatisticamente significantes, com valor de P<0,0001. As menores diferenças foram encontradas nas tomografias computadorizadas de feixe cônico.Submitted by Janser dos Santos Nascimento (janser.nascimento@unigranrio.com.br) on 2016-11-11T12:49:00Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Marlei de Fatima Bonella Zorzal.pdf: 8993862 bytes, checksum: 2ba6b8afc99a72e85a66b65b6f9af067 (MD5)Made available in DSpace on 2016-11-11T12:49:00Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Marlei de Fatima Bonella Zorzal.pdf: 8993862 bytes, checksum: 2ba6b8afc99a72e85a66b65b6f9af067 (MD5) Previous issue date: 2007-04-13CNPqapplication/pdfporUniversidade do Grande RioPrograma de Pós-Graduação em OdontologiaUNIGRANRIOBrasilUnigranrio::Odontologiahttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessOdontologiaImplantes dentáriosTomografiaTomografia computadorizada de feixe cônicoODONTOLOGIAAvaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio secoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisreponame:Biblioteca Digital de Teses e Dissertações da UNIGRANRIOinstname:Universidade do Grande Rio (UNIGRANRIO)instacron:UNIGRANRIOLICENSElicense.txtlicense.txttext/plain; charset=utf-81982http://localhost:8080/tede/bitstream/tede/99/1/license.txt4a50535e8405f611398e6e2d408dbd1bMD51CC-LICENSElicense_urllicense_urltext/plain; charset=utf-849http://localhost:8080/tede/bitstream/tede/99/2/license_url4afdbb8c545fd630ea7db775da747b2fMD52license_textlicense_texttext/html; charset=utf-80http://localhost:8080/tede/bitstream/tede/99/3/license_textd41d8cd98f00b204e9800998ecf8427eMD53license_rdflicense_rdfapplication/rdf+xml; charset=utf-80http://localhost:8080/tede/bitstream/tede/99/4/license_rdfd41d8cd98f00b204e9800998ecf8427eMD54ORIGINALMarlei de Fatima Bonella Zorzal.pdfMarlei de Fatima Bonella Zorzal.pdfapplication/pdf8993862http://localhost:8080/tede/bitstream/tede/99/5/Marlei+de+Fatima+Bonella+Zorzal.pdf2ba6b8afc99a72e85a66b65b6f9af067MD55tede/992016-11-11 10:49:01.0oai:localhost: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Biblioteca Digital de Teses e Dissertaçõeshttp://tede.unigranrio.edu.br/PUBhttp://tede.unigranrio.edu.br/oai/requestrepositorio@instituicao.br||repositorio@instituicao.bropendoar:2016-11-11T12:49:01Biblioteca Digital de Teses e Dissertações da UNIGRANRIO - Universidade do Grande Rio (UNIGRANRIO)false
dc.title.por.fl_str_mv Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco
title Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco
spellingShingle Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco
Zorzal, Marlei de Fátima Bonella
Odontologia
Implantes dentários
Tomografia
Tomografia computadorizada de feixe cônico
ODONTOLOGIA
title_short Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco
title_full Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco
title_fullStr Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco
title_full_unstemmed Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco
title_sort Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco
author Zorzal, Marlei de Fátima Bonella
author_facet Zorzal, Marlei de Fátima Bonella
author_role author
dc.contributor.advisor1.fl_str_mv Harari, Nassim David
dc.contributor.referee1.fl_str_mv Cançado, Renata Pittella
dc.contributor.referee2.fl_str_mv Raymundo Júnior, Rubens
dc.contributor.referee3.fl_str_mv Reis, Rodrigo Sant'anna Aguiar dos
dc.contributor.author.fl_str_mv Zorzal, Marlei de Fátima Bonella
contributor_str_mv Harari, Nassim David
Cançado, Renata Pittella
Raymundo Júnior, Rubens
Reis, Rodrigo Sant'anna Aguiar dos
dc.subject.por.fl_str_mv Odontologia
Implantes dentários
Tomografia
Tomografia computadorizada de feixe cônico
topic Odontologia
Implantes dentários
Tomografia
Tomografia computadorizada de feixe cônico
ODONTOLOGIA
dc.subject.cnpq.fl_str_mv ODONTOLOGIA
description Dental Implant treatment planning requires an accurate evaluation of bone site which includes density, width and height as well the relationship with anatomic structures such as maxillary sinus and mandibular canal. In order to have precise dental implant treatment it is important to have radiographies exams that would provide diagnosis, good quality images and accuracy to the treatment. The present study aims to evaluate the accuracy of conventional linear tomography and cone beam computerized tomography compared to predetermined and marked points of references in five dry mandibles and maxillas skulls. After all tomography were performed, the dry mandibular and maxilla bones were prepared for measurements thus considered real measurements. Dry bone and conventional linear tomography measurements were performed using the obtained image using the program AutoCAD® while the cone beam computerized tomography measurements were recorded using Dental Slice 2.4.3 software (BIOPARTS - prototipagem biomédica). Regarding, statistical analyses of the results, Wilcoxon non parametric statistic test showed differences between dry bones and cone beam computerized tomography (P<0,0001). There were differences between dry bones and conventional linear tomography (P< 0,0001). In addition, there were differences between cone beam computerized tomography and conventional linear tomography (P< 0,0001). Concerning the preciseness of technique, Mann-Whitney non parametric statistic test demonstrate that both tomography methods presented statistic significant differences, showing P<0,0001. Although, the cone beam computerized tomography presented with lower statistical significant differences.
publishDate 2007
dc.date.issued.fl_str_mv 2007-04-13
dc.date.accessioned.fl_str_mv 2016-11-11T12:49:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv ZORZAL, Marlei de Fátima Bonella. Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco. 2007. 146 f. Dissertação (Mestrado em Odontologia) - Universidade do Grande Rio “Prof. José de Souza Herdy", Duque de Caxias.
dc.identifier.uri.fl_str_mv http://localhost:8080/tede/handle/tede/99
identifier_str_mv ZORZAL, Marlei de Fátima Bonella. Avaliação da fidelidade das tomografias convencional linear e computadorizada de feixe cônico às mensurações morfométricas em crânio seco. 2007. 146 f. Dissertação (Mestrado em Odontologia) - Universidade do Grande Rio “Prof. José de Souza Herdy", Duque de Caxias.
url http://localhost:8080/tede/handle/tede/99
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade do Grande Rio
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Odontologia
dc.publisher.initials.fl_str_mv UNIGRANRIO
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Unigranrio::Odontologia
publisher.none.fl_str_mv Universidade do Grande Rio
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UNIGRANRIO
instname:Universidade do Grande Rio (UNIGRANRIO)
instacron:UNIGRANRIO
instname_str Universidade do Grande Rio (UNIGRANRIO)
instacron_str UNIGRANRIO
institution UNIGRANRIO
reponame_str Biblioteca Digital de Teses e Dissertações da UNIGRANRIO
collection Biblioteca Digital de Teses e Dissertações da UNIGRANRIO
bitstream.url.fl_str_mv http://localhost:8080/tede/bitstream/tede/99/1/license.txt
http://localhost:8080/tede/bitstream/tede/99/2/license_url
http://localhost:8080/tede/bitstream/tede/99/3/license_text
http://localhost:8080/tede/bitstream/tede/99/4/license_rdf
http://localhost:8080/tede/bitstream/tede/99/5/Marlei+de+Fatima+Bonella+Zorzal.pdf
bitstream.checksum.fl_str_mv 4a50535e8405f611398e6e2d408dbd1b
4afdbb8c545fd630ea7db775da747b2f
d41d8cd98f00b204e9800998ecf8427e
d41d8cd98f00b204e9800998ecf8427e
2ba6b8afc99a72e85a66b65b6f9af067
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UNIGRANRIO - Universidade do Grande Rio (UNIGRANRIO)
repository.mail.fl_str_mv repositorio@instituicao.br||repositorio@instituicao.br
_version_ 1811013916897050624