Texto Completo: https://periodicos.unb.br/index.php/paranoa/article/view/30341
Resumo: The adoption of natural ventilation to replace mechanical ventilation can contribute to reducing the residential consumption of electrical energy. Among the possible solutions is the use of windcatchers, an ancient architectural solution from the Persian people, for the conditioning of indoor environments, reducing the energy consumption and reaching efficient levels of thermal comfort. Windcatchers applied to the buildings can function through the differences of wind pressure that affect the facade or due to temperature variation: cold air enters through an opening, cooling the interior of the room and pushing hot air out of the building. The development of the work followed the methodological steps: 1) determination of the reduced models, 2) definition of the test parameters, 3) sensor programming and 4) wind tunnel test. The results obtained in the wind tunnel made it possible to evaluate the best windcatcher configuration for each case, aiming to reduce the internal temperature of the environments. In addition, it was possible to conclude that the temperature variation of 0.5 ° C achieved can contribute to the reduction of electricity consumption and, at the same, time preserve or increase the thermal comfort of users.  
id UNB-28_f61124fe05e18e29a23549a191010ab3
oai_identifier_str oai:ojs.pkp.sfu.ca:article/30341
network_acronym_str UNB-28
network_name_str P@ranoá
repository_id_str
spelling Windcatcher study: Wind Tunnel Tests in Residential BuildingsEstudio de torre de viento: ensayo de túnel de viento en edifícios residencialesEstudo de Torre de Vento: Ensaio em Túnel de Vento em Edificações Residenciaiseficiência energéticatorre de ventoconforto térmicotúnel de ventoventilação naturalEficiencia Energetica; Torre de Viento; Bienestar Termal; Túnel de Viento; Ventilación Naturalenergy efficiency; wind catcher thermal comfort; wind tunnel; natural ventilationThe adoption of natural ventilation to replace mechanical ventilation can contribute to reducing the residential consumption of electrical energy. Among the possible solutions is the use of windcatchers, an ancient architectural solution from the Persian people, for the conditioning of indoor environments, reducing the energy consumption and reaching efficient levels of thermal comfort. Windcatchers applied to the buildings can function through the differences of wind pressure that affect the facade or due to temperature variation: cold air enters through an opening, cooling the interior of the room and pushing hot air out of the building. The development of the work followed the methodological steps: 1) determination of the reduced models, 2) definition of the test parameters, 3) sensor programming and 4) wind tunnel test. The results obtained in the wind tunnel made it possible to evaluate the best windcatcher configuration for each case, aiming to reduce the internal temperature of the environments. In addition, it was possible to conclude that the temperature variation of 0.5 ° C achieved can contribute to the reduction of electricity consumption and, at the same, time preserve or increase the thermal comfort of users.  La adopción de la ventilación natural como sustituta de la ventilación mecánica puede contribuir a reducir el consumo de electricidad del hogar. Entre las posibles soluciones está el uso de torres de viento - la solución arquitectónica original del antiguo pueblo persa - para el acondicionamiento de ambientes internos, reduciendo el consumo de energía con ganancias significativas en bienestar termal. Las torres de viento aplicadas a los edificios pueden funcionar como consecuencia de la diferencia de la presión del viento en la fachada o debido a la variación de la temperatura: el aire frío entra por una abertura, enfriando el interior del lugar y empujando el aire caliente fuera del edificio. El desarrollo de los trabajos se dividió en las siguientes etapas metodológicas: 1) determinación de los modelos reducidos, 2) definición de los parámetros de prueba, 3) programación de los sensores y 4) pruebas en un túnel de viento. Los resultados obtenidos en el túnel de viento permitieron evaluar la mejor configuración de torre de viento para cada caso, con el objetivo de reducir la temperatura interna de los ambientes. Además, fue posible concluir que la variación de temperatura de 0,5°C lograda puede contribuir a la reducción de consumo de energía y al mismo tiempo preservar o ampliar el bienestar térmico de los usuarios.A adoção da ventilação natural em substituição à ventilação mecânica pode contribuir para a redução do consumo de energia elétrica das residências. Dentre as soluções possíveis está a utilização de torres de vento, solução arquitetônica original milenar do povo persa, para o condicionamento de ambientes internos, reduzindo o consumo de energia com ganhos significativos no quesito do conforto térmico. As torres de vento aplicadas às edificações podem funcionar como consequência da diferença de pressão do vento que incide na fachada ou devido à variação de temperatura: o ar frio entra por uma abertura, refrigerando o interior do local e empurrando o ar quente para fora do edifício. O desenvolvimento do trabalho foi dividido nas seguintes etapas metodológicas: 1) determinação dos modelos reduzidos, 2) definição dos parâmetros de ensaio, 3) programação de sensores e 4) ensaio em túnel de vento. Os resultados obtidos no túnel de vento permitiram avaliar a melhor configuração de torre de vento para cada caso, visando reduzir a temperatura interna dos ambientes. Além disso, foi possível concluir que a variação de temperatura de 0,5°C alcançada pode contribuir para a redução de consumo de energia elétrica e ao mesmo tempo preservar ou ampliar o conforto térmico dos usuários.Programa de Pós-graduação em Arquitetura e Urbanismo, Faculdade de Arquitetura e Urbanismo2020-05-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://periodicos.unb.br/index.php/paranoa/article/view/3034110.18830/issn.1679-0944.n27.2020.03Paranoá; Vol. 13 No. 27 (2020): January/June Edition; 37-58Paranoá; v. 13 n. 27 (2020): Fluxo contínuo - Janeiro/Junho ; 37-581679-09441677-7395reponame:P@ranoáinstname:Universidade de Brasília (UnB)instacron:UNBporhttps://periodicos.unb.br/index.php/paranoa/article/view/30341/26037Copyright (c) 2020 Paranoá: cadernos de arquitetura e urbanismoinfo:eu-repo/semantics/openAccessCaroline Oliveira Silva, AnneDimitrios Christakou, EvangelosSantos da Silva, LenildoAlves da Silva Júnior, FélixMarcia Coutinho Gurjao, Claudia2024-02-08T14:26:29Zoai:ojs.pkp.sfu.ca:article/30341Revistahttps://periodicos.unb.br/index.php/paranoaPUBhttps://periodicos.unb.br/index.php/paranoa/oaiparanoa@unb.br1679-09441677-7395opendoar:2024-02-08T14:26:29P@ranoá - Universidade de Brasília (UnB)false
dc.title.none.fl_str_mv Windcatcher study: Wind Tunnel Tests in Residential Buildings
Estudio de torre de viento: ensayo de túnel de viento en edifícios residenciales
Estudo de Torre de Vento: Ensaio em Túnel de Vento em Edificações Residenciais
title Windcatcher study: Wind Tunnel Tests in Residential Buildings
spellingShingle Windcatcher study: Wind Tunnel Tests in Residential Buildings
Caroline Oliveira Silva, Anne
eficiência energética
torre de vento
conforto térmico
túnel de vento
ventilação natural
Eficiencia Energetica; Torre de Viento; Bienestar Termal; Túnel de Viento; Ventilación Natural
energy efficiency; wind catcher thermal comfort; wind tunnel; natural ventilation
title_short Windcatcher study: Wind Tunnel Tests in Residential Buildings
title_full Windcatcher study: Wind Tunnel Tests in Residential Buildings
title_fullStr Windcatcher study: Wind Tunnel Tests in Residential Buildings
title_full_unstemmed Windcatcher study: Wind Tunnel Tests in Residential Buildings
title_sort Windcatcher study: Wind Tunnel Tests in Residential Buildings
author Caroline Oliveira Silva, Anne
author_facet Caroline Oliveira Silva, Anne
Dimitrios Christakou, Evangelos
Santos da Silva, Lenildo
Alves da Silva Júnior, Félix
Marcia Coutinho Gurjao, Claudia
author_role author
author2 Dimitrios Christakou, Evangelos
Santos da Silva, Lenildo
Alves da Silva Júnior, Félix
Marcia Coutinho Gurjao, Claudia
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Caroline Oliveira Silva, Anne
Dimitrios Christakou, Evangelos
Santos da Silva, Lenildo
Alves da Silva Júnior, Félix
Marcia Coutinho Gurjao, Claudia
dc.subject.por.fl_str_mv eficiência energética
torre de vento
conforto térmico
túnel de vento
ventilação natural
Eficiencia Energetica; Torre de Viento; Bienestar Termal; Túnel de Viento; Ventilación Natural
energy efficiency; wind catcher thermal comfort; wind tunnel; natural ventilation
topic eficiência energética
torre de vento
conforto térmico
túnel de vento
ventilação natural
Eficiencia Energetica; Torre de Viento; Bienestar Termal; Túnel de Viento; Ventilación Natural
energy efficiency; wind catcher thermal comfort; wind tunnel; natural ventilation
description The adoption of natural ventilation to replace mechanical ventilation can contribute to reducing the residential consumption of electrical energy. Among the possible solutions is the use of windcatchers, an ancient architectural solution from the Persian people, for the conditioning of indoor environments, reducing the energy consumption and reaching efficient levels of thermal comfort. Windcatchers applied to the buildings can function through the differences of wind pressure that affect the facade or due to temperature variation: cold air enters through an opening, cooling the interior of the room and pushing hot air out of the building. The development of the work followed the methodological steps: 1) determination of the reduced models, 2) definition of the test parameters, 3) sensor programming and 4) wind tunnel test. The results obtained in the wind tunnel made it possible to evaluate the best windcatcher configuration for each case, aiming to reduce the internal temperature of the environments. In addition, it was possible to conclude that the temperature variation of 0.5 ° C achieved can contribute to the reduction of electricity consumption and, at the same, time preserve or increase the thermal comfort of users.  
publishDate 2020
dc.date.none.fl_str_mv 2020-05-08
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.unb.br/index.php/paranoa/article/view/30341
10.18830/issn.1679-0944.n27.2020.03
url https://periodicos.unb.br/index.php/paranoa/article/view/30341
identifier_str_mv 10.18830/issn.1679-0944.n27.2020.03
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://periodicos.unb.br/index.php/paranoa/article/view/30341/26037
dc.rights.driver.fl_str_mv Copyright (c) 2020 Paranoá: cadernos de arquitetura e urbanismo
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2020 Paranoá: cadernos de arquitetura e urbanismo
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Programa de Pós-graduação em Arquitetura e Urbanismo, Faculdade de Arquitetura e Urbanismo
publisher.none.fl_str_mv Programa de Pós-graduação em Arquitetura e Urbanismo, Faculdade de Arquitetura e Urbanismo
dc.source.none.fl_str_mv Paranoá; Vol. 13 No. 27 (2020): January/June Edition; 37-58
Paranoá; v. 13 n. 27 (2020): Fluxo contínuo - Janeiro/Junho ; 37-58
1679-0944
1677-7395
reponame:P@ranoá
instname:Universidade de Brasília (UnB)
instacron:UNB
instname_str Universidade de Brasília (UnB)
instacron_str UNB
institution UNB
reponame_str P@ranoá
collection P@ranoá
repository.name.fl_str_mv P@ranoá - Universidade de Brasília (UnB)
repository.mail.fl_str_mv paranoa@unb.br
_version_ 1797066979675209728