Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio

Detalhes bibliográficos
Autor(a) principal: Pereira, Eduardo Ferreira
Data de Publicação: 2015
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UnB
Texto Completo: http://repositorio.unb.br/handle/10482/20496
http://dx.doi.org/10.26512/2015.07.T.20496
Resumo: Tese (doutorado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2015.
id UNB_3016e385c01b6109bf25c20668a06d30
oai_identifier_str oai:repositorio.unb.br:10482/20496
network_acronym_str UNB
network_name_str Repositório Institucional da UnB
repository_id_str
spelling Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídioFluorimetriaAutomaçãoBrometo de etídioTese (doutorado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2015.O Brometo de Etídio (BE) é um composto fluorescente que tem seu rendimento quântico muito aumentado quando intercalado à moléculas de DNA e RNA e, por isto, é usado para detecção destas espécies em procedimentos de eletroferese em gel. Devido a estas características, esta substância é considerada perigosa, pois pode causar danos ao material genético humano sendo classificado como um agente mutagênico /tóxico. Para realização do seu descarte é necessário um processo de inertização, sendo um dos mais aplicados o proposto por Lunn e Sansone em que são utilizados o ácido hipofosfórico e o nitríto de sódio para oxidação da substância. Porém, esta é uma reação de longa duração e a sua finalização deve ser atestada com o uso da detecção por fluorescência. Considerando este aspecto, o principal objetivo do trabalho foi construir e avaliar um sistema automatizado de baixo custo com detecção fluorimétrica, empregando-se um LED (máximo de emissão em 535 nm) para monitorar a degradação do BE. Este instrumento é controlado por microcontroladores (PIC 16F877A e PIC 16F628) que são responsáveis pelos controles dos processos de fluxo das amostras e do fluido carreador e por adquirir e processar o sinal do sistema de detecção, composto de dois fotodiodos e como filtros para, emissão do BE, foram utilizados plásticos de coloração alaranjada. O Fluorímetro proposto foi avaliado tanto em batelada quanto em um sistema de fluxo e apresentou limites de detecção de 0,33 mg L-1 no sistema de fluxo com abordagem stoped-flow e 0,04 mg L-1 em batelada (utilizando cubeta). As medidas realizadas com o instrumento foram comparadas ao de um fluorímetro comercial de bancada e em todas as comparações não foram observadas diferenças significativas ao nível de 95% de confiança. Foram realizados testes para verificar se o sistema de decisão do instrumento proposto era confiável para indicar automaticamente o final da degradação sendo observada uma taxa de 100% de acerto para as amostras testadas com concentrações acima do limite máximo permitido e abaixo deste limite (5 mg L-1). Alternativamente, avaliou-se a possibilidade de uso de um sistema de detecção de BE utilizando um LED como fonte de excitação e medidas das componentes RGB de imagens a partir de um aplicativo e da câmera de um aparelho celular. Para esta abordagem foi encontrado um limite de detecção de 0,91 mg L-1 utilizando apenas componente R. Comparando-se os resultados obtidos para amostras fortificadas com BE realizadas com o fluorímetro proposto e com a detecção via celular com os resultados obtidos com um espectrofluorímetro comercial, não foram observadas diferenças significativas ao nível de 95 % de confiança. O Fluorímetro de LED proposto se mostrou eficiente e teve um rendimento satisfatório a um baixo custo (cerca de US$ 200) podendo ser aplicado para a detecção de BE no procedimento de descarte ou na detecção destes em amostras residuais.Ethidium Bromide (BE) is a fluorescent compound which has a significant enhancement of quantum yield when intercalated with RNA and DNA molecules and, due to such effect, it is applied for detection of these species in gel electrophoresis. For that reason, BE is considered dangerous, producing damages to human genetic material and classified as a mutagenic/toxic agent. In order to discard BE residues, is necessary a prior process to turn the substance inert and one of the most applied protocols is the proposed by Lunn and Sansone, where hipofosforic acid and sodium nitrite are used to oxidize the BE. However, this reaction requires a long time period and its finalization must be attested by fluorescence measurements. Considering this, the main objective of this work was to fabricate and evaluate a low cost automated system with fluorometric detection, using a LED (maximum emission in 535 nm) to to monitor BE degradation. The proposed instrument is controlled by microcontrollers (PIC 16F877A and PIC 16F628) that controls the sample and carrier flows and performs the acquisition and processing of the analytical signal from the detector, comprising two photodiodes covered by two pieces of transparent orange plastic. The proposed fluorometer was tested with the use of batch or flow based strategies. Using a stopped-flow system, the limit of detection of 0.33 mg L-1 was achieved and for the batch determination the detection limit was 0.04 mg L-1. The determinations performed with the proposed LED fluorometer were compared to the determinations performed with a commercial spectrofluorometer with no significant differences at 95 % confidence level. Tests were also conducted to verify if the decision system of the proposed instrument was reliable to automatically indicate the end of degradation, being checked 100 % of accuracy for the tested samples with BE concentrations beyond and below the limit of concentration of 5 mg L-1. Alternatively, the detection of BE using a green LED as excitation source and measurements of RGB pattern from photographic images acquired by a cell phone was evaluated. For this approach, the detection limit of 0.91 mg L-1 was stimated using only the Red component of RGB. By comparing the results acquired with the proposed fluorometer/cell phone detection with the data obtained with a commercial spectrofluorometer for BE fortified samples, no significant differences were observed at the 95 % confidence level. The proposed LED Fluorometer was efficient and had a satisfactory performance at a low cost (US$ 200) and can be applied to the detection of BE in the disposal procedure or detecting in residual samples.Fonseca, AlexandrePereira, Eduardo Ferreira2016-05-26T17:53:27Z2016-05-26T17:53:27Z2016-05-262015-07-08info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdfPEREIRA, Eduardo Ferreira. Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio. 2015. xvii, 111 f. Tese (Doutorado em Química)—Universidade de Brasília, Brasília, 2015.http://repositorio.unb.br/handle/10482/20496http://dx.doi.org/10.26512/2015.07.T.20496A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.info:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UnBinstname:Universidade de Brasília (UnB)instacron:UNB2023-07-11T00:38:52Zoai:repositorio.unb.br:10482/20496Repositório InstitucionalPUBhttps://repositorio.unb.br/oai/requestrepositorio@unb.bropendoar:2023-07-11T00:38:52Repositório Institucional da UnB - Universidade de Brasília (UnB)false
dc.title.none.fl_str_mv Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio
title Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio
spellingShingle Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio
Pereira, Eduardo Ferreira
Fluorimetria
Automação
Brometo de etídio
title_short Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio
title_full Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio
title_fullStr Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio
title_full_unstemmed Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio
title_sort Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio
author Pereira, Eduardo Ferreira
author_facet Pereira, Eduardo Ferreira
author_role author
dc.contributor.none.fl_str_mv Fonseca, Alexandre
dc.contributor.author.fl_str_mv Pereira, Eduardo Ferreira
dc.subject.por.fl_str_mv Fluorimetria
Automação
Brometo de etídio
topic Fluorimetria
Automação
Brometo de etídio
description Tese (doutorado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2015.
publishDate 2015
dc.date.none.fl_str_mv 2015-07-08
2016-05-26T17:53:27Z
2016-05-26T17:53:27Z
2016-05-26
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv PEREIRA, Eduardo Ferreira. Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio. 2015. xvii, 111 f. Tese (Doutorado em Química)—Universidade de Brasília, Brasília, 2015.
http://repositorio.unb.br/handle/10482/20496
http://dx.doi.org/10.26512/2015.07.T.20496
identifier_str_mv PEREIRA, Eduardo Ferreira. Desenvolvimento de sistema automatizado para o monitoramento da degradação de resíduos de brometo de etídio. 2015. xvii, 111 f. Tese (Doutorado em Química)—Universidade de Brasília, Brasília, 2015.
url http://repositorio.unb.br/handle/10482/20496
http://dx.doi.org/10.26512/2015.07.T.20496
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UnB
instname:Universidade de Brasília (UnB)
instacron:UNB
instname_str Universidade de Brasília (UnB)
instacron_str UNB
institution UNB
reponame_str Repositório Institucional da UnB
collection Repositório Institucional da UnB
repository.name.fl_str_mv Repositório Institucional da UnB - Universidade de Brasília (UnB)
repository.mail.fl_str_mv repositorio@unb.br
_version_ 1818900916130021376