Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UnB |
Texto Completo: | http://repositorio.unb.br/handle/10482/30383 http://dx.doi.org/10.1590/1678-775720150600 |
Resumo: | Objective: to evaluate the influence of an application technique of a glass-fiber post using self-adhesive resin cements on the push-out bond strength and the presence of bubbles in the root thirds. The cements were either applied according to the manufacturer's instruction or using a commercial delivering system (Centrix), at which the cement pastes were collected and applied after manipulation. Material and Methods: Self-adhesive resin cements (RelyX U200/3M ESPE-U200; Maxcem Elite/Kerr-MAX; Clearfil SA Cement/Kuraray-CSA) and a conventional cement (RelyX ARC/3M ESPE-ARC) were used to cement a post and applied either based on the manufacturer's instructions or using a Centrix syringe to deliver the cements directly onto the post of choice, or directly into canal. The roots were scanned with a micro-computed tomography (μCT) and then sectioned into nine 1-mm thick slices for a push-out bond strength test. The μCT images showed the percentage of bubbles in the root thirds (cervical, medium, and apical). Data were analyzed with three-way ANOVA/Tukey (α=0.05). Results: Triple interaction was not significant (p>0.05). The interaction “material” vs “root third” was not significant. A significant interaction was observed between “material” vs “application technique” (p<0.05). For ARC, U200, and MAX, significantly lower percentages of bubbles were observed when the Centrix syringe delivered the cements. Equivalent percentages of voids were observed for CSA, irrespective of the application technique (p>0.05). Significantly higher bond strength was observed when the self-adhesive resin cements were applied using the Centrix delivery system, in comparison with the manufacturer's instructions (p<0.05). Bond strength varied with the root third: cervical>medium>apical (p<0.05). No correlations were found between the bond strength and voids. Conclusions: Bond strength and voids are negatively influenced by the conventional application technique for luting fiber posts. The delivery system (Centrix) seems to produce better results when cementing fiber posts. |
id |
UNB_37f6e73eb7061fb8de7ac22c8081fecd |
---|---|
oai_identifier_str |
oai:repositorio.unb.br:10482/30383 |
network_acronym_str |
UNB |
network_name_str |
Repositório Institucional da UnB |
repository_id_str |
|
spelling |
Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentinForçaCimentos dentáriosRaios XObjective: to evaluate the influence of an application technique of a glass-fiber post using self-adhesive resin cements on the push-out bond strength and the presence of bubbles in the root thirds. The cements were either applied according to the manufacturer's instruction or using a commercial delivering system (Centrix), at which the cement pastes were collected and applied after manipulation. Material and Methods: Self-adhesive resin cements (RelyX U200/3M ESPE-U200; Maxcem Elite/Kerr-MAX; Clearfil SA Cement/Kuraray-CSA) and a conventional cement (RelyX ARC/3M ESPE-ARC) were used to cement a post and applied either based on the manufacturer's instructions or using a Centrix syringe to deliver the cements directly onto the post of choice, or directly into canal. The roots were scanned with a micro-computed tomography (μCT) and then sectioned into nine 1-mm thick slices for a push-out bond strength test. The μCT images showed the percentage of bubbles in the root thirds (cervical, medium, and apical). Data were analyzed with three-way ANOVA/Tukey (α=0.05). Results: Triple interaction was not significant (p>0.05). The interaction “material” vs “root third” was not significant. A significant interaction was observed between “material” vs “application technique” (p<0.05). For ARC, U200, and MAX, significantly lower percentages of bubbles were observed when the Centrix syringe delivered the cements. Equivalent percentages of voids were observed for CSA, irrespective of the application technique (p>0.05). Significantly higher bond strength was observed when the self-adhesive resin cements were applied using the Centrix delivery system, in comparison with the manufacturer's instructions (p<0.05). Bond strength varied with the root third: cervical>medium>apical (p<0.05). No correlations were found between the bond strength and voids. Conclusions: Bond strength and voids are negatively influenced by the conventional application technique for luting fiber posts. The delivery system (Centrix) seems to produce better results when cementing fiber posts.Faculdade De Odontologia De Bauru - USP2017-12-07T05:18:51Z2017-12-07T05:18:51Z2016-09info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfPEDREIRA, Ana Paula Ribeiro do Vale et al. Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin. Journal of Applied Oral Science, Bauru, v. 24, n. 5, p. 437-446, set./out. 2016. Disponível em: <http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572016000500437&lng=en&nrm=iso>. Acesso em: 19 dez. 2017. doi: http://dx.doi.org/10.1590/1678-775720150600.http://repositorio.unb.br/handle/10482/30383http://dx.doi.org/10.1590/1678-775720150600Journal of Applied Oral Science - This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited (CC BY 4.0). Fonte: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572016000500437&lng=en&nrm=iso. Acesso em: 19 dez. 2017.info:eu-repo/semantics/openAccessPedreira, Ana Paula Ribeiro do ValeD'Alpino, Paulo Henrique PerlattiPereira, Patrícia Nóbrega RodriguesChaves, Sasha BraunWang, LindaHilgert, LeandroGarcia, Fernanda Cristina Pimentelengreponame:Repositório Institucional da UnBinstname:Universidade de Brasília (UnB)instacron:UNB2023-05-24T23:06:03Zoai:repositorio.unb.br:10482/30383Repositório InstitucionalPUBhttps://repositorio.unb.br/oai/requestrepositorio@unb.bropendoar:2023-05-24T23:06:03Repositório Institucional da UnB - Universidade de Brasília (UnB)false |
dc.title.none.fl_str_mv |
Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin |
title |
Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin |
spellingShingle |
Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin Pedreira, Ana Paula Ribeiro do Vale Força Cimentos dentários Raios X |
title_short |
Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin |
title_full |
Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin |
title_fullStr |
Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin |
title_full_unstemmed |
Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin |
title_sort |
Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin |
author |
Pedreira, Ana Paula Ribeiro do Vale |
author_facet |
Pedreira, Ana Paula Ribeiro do Vale D'Alpino, Paulo Henrique Perlatti Pereira, Patrícia Nóbrega Rodrigues Chaves, Sasha Braun Wang, Linda Hilgert, Leandro Garcia, Fernanda Cristina Pimentel |
author_role |
author |
author2 |
D'Alpino, Paulo Henrique Perlatti Pereira, Patrícia Nóbrega Rodrigues Chaves, Sasha Braun Wang, Linda Hilgert, Leandro Garcia, Fernanda Cristina Pimentel |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Pedreira, Ana Paula Ribeiro do Vale D'Alpino, Paulo Henrique Perlatti Pereira, Patrícia Nóbrega Rodrigues Chaves, Sasha Braun Wang, Linda Hilgert, Leandro Garcia, Fernanda Cristina Pimentel |
dc.subject.por.fl_str_mv |
Força Cimentos dentários Raios X |
topic |
Força Cimentos dentários Raios X |
description |
Objective: to evaluate the influence of an application technique of a glass-fiber post using self-adhesive resin cements on the push-out bond strength and the presence of bubbles in the root thirds. The cements were either applied according to the manufacturer's instruction or using a commercial delivering system (Centrix), at which the cement pastes were collected and applied after manipulation. Material and Methods: Self-adhesive resin cements (RelyX U200/3M ESPE-U200; Maxcem Elite/Kerr-MAX; Clearfil SA Cement/Kuraray-CSA) and a conventional cement (RelyX ARC/3M ESPE-ARC) were used to cement a post and applied either based on the manufacturer's instructions or using a Centrix syringe to deliver the cements directly onto the post of choice, or directly into canal. The roots were scanned with a micro-computed tomography (μCT) and then sectioned into nine 1-mm thick slices for a push-out bond strength test. The μCT images showed the percentage of bubbles in the root thirds (cervical, medium, and apical). Data were analyzed with three-way ANOVA/Tukey (α=0.05). Results: Triple interaction was not significant (p>0.05). The interaction “material” vs “root third” was not significant. A significant interaction was observed between “material” vs “application technique” (p<0.05). For ARC, U200, and MAX, significantly lower percentages of bubbles were observed when the Centrix syringe delivered the cements. Equivalent percentages of voids were observed for CSA, irrespective of the application technique (p>0.05). Significantly higher bond strength was observed when the self-adhesive resin cements were applied using the Centrix delivery system, in comparison with the manufacturer's instructions (p<0.05). Bond strength varied with the root third: cervical>medium>apical (p<0.05). No correlations were found between the bond strength and voids. Conclusions: Bond strength and voids are negatively influenced by the conventional application technique for luting fiber posts. The delivery system (Centrix) seems to produce better results when cementing fiber posts. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-09 2017-12-07T05:18:51Z 2017-12-07T05:18:51Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
PEDREIRA, Ana Paula Ribeiro do Vale et al. Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin. Journal of Applied Oral Science, Bauru, v. 24, n. 5, p. 437-446, set./out. 2016. Disponível em: <http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572016000500437&lng=en&nrm=iso>. Acesso em: 19 dez. 2017. doi: http://dx.doi.org/10.1590/1678-775720150600. http://repositorio.unb.br/handle/10482/30383 http://dx.doi.org/10.1590/1678-775720150600 |
identifier_str_mv |
PEDREIRA, Ana Paula Ribeiro do Vale et al. Effects of the application techniques of self-adhesive resin cements on the interfacial integrity and bond strength of fiber posts to dentin. Journal of Applied Oral Science, Bauru, v. 24, n. 5, p. 437-446, set./out. 2016. Disponível em: <http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572016000500437&lng=en&nrm=iso>. Acesso em: 19 dez. 2017. doi: http://dx.doi.org/10.1590/1678-775720150600. |
url |
http://repositorio.unb.br/handle/10482/30383 http://dx.doi.org/10.1590/1678-775720150600 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UnB instname:Universidade de Brasília (UnB) instacron:UNB |
instname_str |
Universidade de Brasília (UnB) |
instacron_str |
UNB |
institution |
UNB |
reponame_str |
Repositório Institucional da UnB |
collection |
Repositório Institucional da UnB |
repository.name.fl_str_mv |
Repositório Institucional da UnB - Universidade de Brasília (UnB) |
repository.mail.fl_str_mv |
repositorio@unb.br |
_version_ |
1814508231417921536 |