Estudo com elementos finitos em vértebras lombares após subtração pedicular

Detalhes bibliográficos
Autor(a) principal: Oppermann, Marcelo
Data de Publicação: 2016
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UnB
Texto Completo: http://repositorio.unb.br/handle/10482/21064
http://dx.doi.org/10.26512/2016.06.D.21064
Resumo: Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2016.
id UNB_79aeb163f5478fc22dc213e581aaa074
oai_identifier_str oai:repositorio.unb.br:10482/21064
network_acronym_str UNB
network_name_str Repositório Institucional da UnB
repository_id_str
spelling Estudo com elementos finitos em vértebras lombares após subtração pedicularFinite element analysis in lumbar vertebrae after pedicular subtractionColuna lombarMétodo dos elementos finitosParafusos ósseos (Ortopedia)Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2016.Os Parafusos Pediculares (PP) estão entre os implantes mais utilizados na ortopedia/neurocirurgia. Este assemelha-se a um parafuso comum, mas com particularidades específicas para o local onde será implantado. Macroscopicamente o osso vertebral contém estruturas que determinam sua característica funcional e duas são mais importantes, na relação com os PP, o pedículo e o corpo vertebral. O pedículo, microscopicamente, é formado por um tecido ósseo mais rígido capaz de aguentar maior carga, já o corpo vertebral, diferentemente, contém uma estrutura mais frágil, e são denominados, respectivamente, de osso cortical e trabecular. Existem duas formas de avaliar a ação mecânica dos PP, através de estudos físicos e com Modelos de Elementos Finitos (MEF). Os MEF são cada vez mais utilizados na prática biomecânica, já que são facilmente modelados, sem necessidade de maquinário especial e muito menos, requerem comissão de ética para sua aprovação. Através da criação de uma malha, adiciona-se propriedades físicas que representem as características do parafuso e do osso, e simula-se cargas. Com isso, é possível avaliar o resultado, em termos de tensão, deslocamento e inferir falhas ao sistema. Aqui, se estudou 5 tipos de parafuso, que representassem a média dos implantes comercializáveis, com desenhos estruturais diferentes entre si. Estes foram inseridos em um cilindro com duas porções, representando o pedículo e o corpo vertebral e submetidos a tração (arrancamento), com uma força de 500N. O objetivo foi de avaliar a tensão nas interfaces osso-parafuso e deslocamento, em duas situações, uma com o modelo intacto, e outro com subtração da área cilíndrica, que representasse o pedículo. O modelo obedeceu o princípio de ser isotrópico e linear. O resultado, sob o prisma do deslocamento, mostrou que na média, os 5 parafusos tiveram uma perda de fixação da ordem de 47%, quando a porção pedicular foi removida e aplicada a carga. Ademais, no que tange a individualidade dos parafusos, houve uma diferença significativa entre os cinco tipos, variando de 21,9% até 92,2% no aumento do deslocamento, no modelo sem a região pedicular. Sob o ponto de vista tensão, nenhum parafuso, em ambos os cenários, obteve valores que alcançassem o ponto de tensão de escoamento do osso trabecular, ou ponto de ruptura definitiva. Aqui, mais uma vez, houve diferença significativa entre os 5 tipos de PP. Muitos PP obtiveram menor tensão quando da subtração pedicular. Este fato é explicado por ser o osso trabecular mais deformável (Módulo de Elasticidade menor), assim passível de gerar menor tensão para um mesmo deslocamento. Enfim, este trabalho conseguiu relatar que numa eventual necessidade de remoção dos pedículos vertebrais, os implantes existentes no mercado apresentam uma grande capacidade de falha, demonstrado por uma um aumento médio de quase 50% no deslocamento do PP, quando 500N de carga é aplicado sob forma de arrancamento.The pedicle screws (PS) are currently the most widely used implants in orthopedics / neurosurgery. They resemble a common bolt, but with specific characteristics to fit into the bone. Macroscopically vertebral bone contains structures that determine their functional feature, but two are most important in relation to the PS, the pedicle and vertebral body. The pedicle microscopically, is formed with a rigid bone tissue, capable of withstanding greater load. The vertebral body, in contrast, contains a more brittle structure. They are named cortical and trabecular bone, respectively. There are two ways to evaluate the mechanical action of the PS, through physical studies and finite element models (FEM). FEM are increasingly used in the biomechanics practice, since they are easily modeled, without the need for special machinery, neither requires ethics committee for approval. By creating a mesh, added with physical properties, that represent the characteristics of the screw and the bone, they can simulate the loads existing in the screw-bone interface. With this, it makes possible to evaluate the results in terms of stress, displacement and interpreted as failure. Here, we studied 5 types of PS, which represent the average of marketable implants with different structural designs. These were inserted into a cylinder with two portions, representing the pedicle and vertebral body and put them to traction (pullout), with a force of 500N in order to evaluate the stress and the strain at the bone-screw interfaces between two situations, one with the intact model, and another with subtraction of the cylindrical area, represented by the pedicle. The model followed the principle to be isotropic and linear. The result, in the light of displacement, showed that on average, the 5 screws have a loss of 47% in fixation, when the pedicle portion was removed. Beside, regarding the individuality of the screws there was a significant difference among the five kinds, ranging from 21,9% to 92,2% increase in displacement, with and without the pedicle region. From the point of view of stress, no screw, in both scenarios, obtained values that reached the yield stress point of the trabecular bone, or point of final break. Here again, there was a significant difference between the five types of PS. Many PS obtained a lower stress when the pedicle was subtracted, a fact that was explained being the trabecular bone more deformable (lower elastic modulus) and likely to generate lower stress for the same displacement. In the end, this work was succeeded to report that if needed, the removal of the vertebral pedicles, the nowadays implants have a large fault capacity, shown by an average increase of almost 50% in the PS displacement, when load of 500N is applied in the form of pullout.Faculdade UnB Gama (FGA)Programa de Pós-Graduação em Engenharia BiomédicaBrasil, Lourdes MattosCardoso, Leandro XavierOppermann, Marcelo2016-07-29T12:27:55Z2016-07-29T12:27:55Z2016-07-292016-06-03info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfOPPERMANN, Marcelo. Estudo com elementos finitos em vértebras lombares após subtração pedicular. 2016. xxi, 184 f., il. Dissertação (Mestrado em Engenharia Biomédica)—Universidade de Brasília, 2016.http://repositorio.unb.br/handle/10482/21064http://dx.doi.org/10.26512/2016.06.D.21064A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.info:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UnBinstname:Universidade de Brasília (UnB)instacron:UNB2024-02-08T21:15:42Zoai:repositorio.unb.br:10482/21064Repositório InstitucionalPUBhttps://repositorio.unb.br/oai/requestrepositorio@unb.bropendoar:2024-02-08T21:15:42Repositório Institucional da UnB - Universidade de Brasília (UnB)false
dc.title.none.fl_str_mv Estudo com elementos finitos em vértebras lombares após subtração pedicular
Finite element analysis in lumbar vertebrae after pedicular subtraction
title Estudo com elementos finitos em vértebras lombares após subtração pedicular
spellingShingle Estudo com elementos finitos em vértebras lombares após subtração pedicular
Oppermann, Marcelo
Coluna lombar
Método dos elementos finitos
Parafusos ósseos (Ortopedia)
title_short Estudo com elementos finitos em vértebras lombares após subtração pedicular
title_full Estudo com elementos finitos em vértebras lombares após subtração pedicular
title_fullStr Estudo com elementos finitos em vértebras lombares após subtração pedicular
title_full_unstemmed Estudo com elementos finitos em vértebras lombares após subtração pedicular
title_sort Estudo com elementos finitos em vértebras lombares após subtração pedicular
author Oppermann, Marcelo
author_facet Oppermann, Marcelo
author_role author
dc.contributor.none.fl_str_mv Brasil, Lourdes Mattos
Cardoso, Leandro Xavier
dc.contributor.author.fl_str_mv Oppermann, Marcelo
dc.subject.por.fl_str_mv Coluna lombar
Método dos elementos finitos
Parafusos ósseos (Ortopedia)
topic Coluna lombar
Método dos elementos finitos
Parafusos ósseos (Ortopedia)
description Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2016.
publishDate 2016
dc.date.none.fl_str_mv 2016-07-29T12:27:55Z
2016-07-29T12:27:55Z
2016-07-29
2016-06-03
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv OPPERMANN, Marcelo. Estudo com elementos finitos em vértebras lombares após subtração pedicular. 2016. xxi, 184 f., il. Dissertação (Mestrado em Engenharia Biomédica)—Universidade de Brasília, 2016.
http://repositorio.unb.br/handle/10482/21064
http://dx.doi.org/10.26512/2016.06.D.21064
identifier_str_mv OPPERMANN, Marcelo. Estudo com elementos finitos em vértebras lombares após subtração pedicular. 2016. xxi, 184 f., il. Dissertação (Mestrado em Engenharia Biomédica)—Universidade de Brasília, 2016.
url http://repositorio.unb.br/handle/10482/21064
http://dx.doi.org/10.26512/2016.06.D.21064
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UnB
instname:Universidade de Brasília (UnB)
instacron:UNB
instname_str Universidade de Brasília (UnB)
instacron_str UNB
institution UNB
reponame_str Repositório Institucional da UnB
collection Repositório Institucional da UnB
repository.name.fl_str_mv Repositório Institucional da UnB - Universidade de Brasília (UnB)
repository.mail.fl_str_mv repositorio@unb.br
_version_ 1814508410116243456