The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective

Detalhes bibliográficos
Autor(a) principal: Silva, Rafaella Carvalho da
Data de Publicação: 2019
Outros Autores: Zoccoli, Thanyze Alice Vicentini, Marães, Vera Regina Fernandes da Silva
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UnB
Texto Completo: https://repositorio.unb.br/handle/10482/36594
https://doi.org/10.1590/s1980-6574201900030012
http://orcid.org/0000-0001-7974-8166
http://orcid.org/0000-0002-8193-300X
http://orcid.org/0000-0002-8895-9624
Resumo: Aim: Surface electromyography (sEMG) has been established as a safe non-invasive method to investigate neuromuscular function. However, the use of this instrument to assess lower limbs of transfemoral amputees still presents a lack of standardization in its methods of signal acquisition and processing. The aim of this study was to review the current state of sEMG utilization to assess transfemoral amputees, the procedures adopted for the acquisition and the functional findings. Methods: This is a literature review. Five electronic databases were searched to find the studies: All relevant information of each study was extracted and registered. Methodological quality was evaluated using a customized checklist. Results: Eight studies followed the inclusion criteria and were included in this paper. Four studies did not reach more than 80% of the quality checklist, few studies fully described the methodology applied. The muscles assessed were similar in all studies, electrodes placement was determined by different criteria. Conclusion: This paper demonstrates that a few studies have used this method to assess this population and the main variable aspect is concerned to the placement of the electrodes. More researches are needed to better understand the neuromuscular behavior of amputees by using sEMG and assist future researches to develop more reproducible and reliable studies.
id UNB_c66c952045fba7e0d8c627709258d3a9
oai_identifier_str oai:repositorio.unb.br:10482/36594
network_acronym_str UNB
network_name_str Repositório Institucional da UnB
repository_id_str
spelling The use of surface electromyography to assess transfemoral amputees : methodological and functional perspectiveEletromiografiaAmputadosAim: Surface electromyography (sEMG) has been established as a safe non-invasive method to investigate neuromuscular function. However, the use of this instrument to assess lower limbs of transfemoral amputees still presents a lack of standardization in its methods of signal acquisition and processing. The aim of this study was to review the current state of sEMG utilization to assess transfemoral amputees, the procedures adopted for the acquisition and the functional findings. Methods: This is a literature review. Five electronic databases were searched to find the studies: All relevant information of each study was extracted and registered. Methodological quality was evaluated using a customized checklist. Results: Eight studies followed the inclusion criteria and were included in this paper. Four studies did not reach more than 80% of the quality checklist, few studies fully described the methodology applied. The muscles assessed were similar in all studies, electrodes placement was determined by different criteria. Conclusion: This paper demonstrates that a few studies have used this method to assess this population and the main variable aspect is concerned to the placement of the electrodes. More researches are needed to better understand the neuromuscular behavior of amputees by using sEMG and assist future researches to develop more reproducible and reliable studies.Faculdade UnB Gama (FGA)Universidade Estadual Paulista2020-01-24T10:32:11Z2020-01-24T10:32:11Z2019info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfSILVA, Rafaella Carvalho da; ZOCCOLI, Thanyze Alice Vicentini; MARÃES, Vera Regina Fernandes da Silva. The use of surface electromyography to assess transfemoral amputees: methodological and functional perspective. Motriz: Revista de Educação Física, v. 25, n. 3, e101995, 2019. Disponível em: http://scielo.br/scielo.php?script=sci_arttext&pid=S1980-65742019000300310. DOI: https://doi.org/10.1590/s1980-6574201900030012. Acesso em: 23 jan. 2020.https://repositorio.unb.br/handle/10482/36594https://doi.org/10.1590/s1980-6574201900030012http://orcid.org/0000-0001-7974-8166http://orcid.org/0000-0002-8193-300Xhttp://orcid.org/0000-0002-8895-9624(CC BY) - Under a license Creative Commons - Version 4.0info:eu-repo/semantics/openAccessSilva, Rafaella Carvalho daZoccoli, Thanyze Alice VicentiniMarães, Vera Regina Fernandes da Silvaengreponame:Repositório Institucional da UnBinstname:Universidade de Brasília (UnB)instacron:UNB2023-08-21T18:28:29Zoai:repositorio.unb.br:10482/36594Repositório InstitucionalPUBhttps://repositorio.unb.br/oai/requestrepositorio@unb.bropendoar:2023-08-21T18:28:29Repositório Institucional da UnB - Universidade de Brasília (UnB)false
dc.title.none.fl_str_mv The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective
title The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective
spellingShingle The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective
Silva, Rafaella Carvalho da
Eletromiografia
Amputados
title_short The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective
title_full The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective
title_fullStr The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective
title_full_unstemmed The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective
title_sort The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective
author Silva, Rafaella Carvalho da
author_facet Silva, Rafaella Carvalho da
Zoccoli, Thanyze Alice Vicentini
Marães, Vera Regina Fernandes da Silva
author_role author
author2 Zoccoli, Thanyze Alice Vicentini
Marães, Vera Regina Fernandes da Silva
author2_role author
author
dc.contributor.author.fl_str_mv Silva, Rafaella Carvalho da
Zoccoli, Thanyze Alice Vicentini
Marães, Vera Regina Fernandes da Silva
dc.subject.por.fl_str_mv Eletromiografia
Amputados
topic Eletromiografia
Amputados
description Aim: Surface electromyography (sEMG) has been established as a safe non-invasive method to investigate neuromuscular function. However, the use of this instrument to assess lower limbs of transfemoral amputees still presents a lack of standardization in its methods of signal acquisition and processing. The aim of this study was to review the current state of sEMG utilization to assess transfemoral amputees, the procedures adopted for the acquisition and the functional findings. Methods: This is a literature review. Five electronic databases were searched to find the studies: All relevant information of each study was extracted and registered. Methodological quality was evaluated using a customized checklist. Results: Eight studies followed the inclusion criteria and were included in this paper. Four studies did not reach more than 80% of the quality checklist, few studies fully described the methodology applied. The muscles assessed were similar in all studies, electrodes placement was determined by different criteria. Conclusion: This paper demonstrates that a few studies have used this method to assess this population and the main variable aspect is concerned to the placement of the electrodes. More researches are needed to better understand the neuromuscular behavior of amputees by using sEMG and assist future researches to develop more reproducible and reliable studies.
publishDate 2019
dc.date.none.fl_str_mv 2019
2020-01-24T10:32:11Z
2020-01-24T10:32:11Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv SILVA, Rafaella Carvalho da; ZOCCOLI, Thanyze Alice Vicentini; MARÃES, Vera Regina Fernandes da Silva. The use of surface electromyography to assess transfemoral amputees: methodological and functional perspective. Motriz: Revista de Educação Física, v. 25, n. 3, e101995, 2019. Disponível em: http://scielo.br/scielo.php?script=sci_arttext&pid=S1980-65742019000300310. DOI: https://doi.org/10.1590/s1980-6574201900030012. Acesso em: 23 jan. 2020.
https://repositorio.unb.br/handle/10482/36594
https://doi.org/10.1590/s1980-6574201900030012
http://orcid.org/0000-0001-7974-8166
http://orcid.org/0000-0002-8193-300X
http://orcid.org/0000-0002-8895-9624
identifier_str_mv SILVA, Rafaella Carvalho da; ZOCCOLI, Thanyze Alice Vicentini; MARÃES, Vera Regina Fernandes da Silva. The use of surface electromyography to assess transfemoral amputees: methodological and functional perspective. Motriz: Revista de Educação Física, v. 25, n. 3, e101995, 2019. Disponível em: http://scielo.br/scielo.php?script=sci_arttext&pid=S1980-65742019000300310. DOI: https://doi.org/10.1590/s1980-6574201900030012. Acesso em: 23 jan. 2020.
url https://repositorio.unb.br/handle/10482/36594
https://doi.org/10.1590/s1980-6574201900030012
http://orcid.org/0000-0001-7974-8166
http://orcid.org/0000-0002-8193-300X
http://orcid.org/0000-0002-8895-9624
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv (CC BY) - Under a license Creative Commons - Version 4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv (CC BY) - Under a license Creative Commons - Version 4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual Paulista
publisher.none.fl_str_mv Universidade Estadual Paulista
dc.source.none.fl_str_mv reponame:Repositório Institucional da UnB
instname:Universidade de Brasília (UnB)
instacron:UNB
instname_str Universidade de Brasília (UnB)
instacron_str UNB
institution UNB
reponame_str Repositório Institucional da UnB
collection Repositório Institucional da UnB
repository.name.fl_str_mv Repositório Institucional da UnB - Universidade de Brasília (UnB)
repository.mail.fl_str_mv repositorio@unb.br
_version_ 1814508190064181248