The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UnB |
Texto Completo: | https://repositorio.unb.br/handle/10482/36594 https://doi.org/10.1590/s1980-6574201900030012 http://orcid.org/0000-0001-7974-8166 http://orcid.org/0000-0002-8193-300X http://orcid.org/0000-0002-8895-9624 |
Resumo: | Aim: Surface electromyography (sEMG) has been established as a safe non-invasive method to investigate neuromuscular function. However, the use of this instrument to assess lower limbs of transfemoral amputees still presents a lack of standardization in its methods of signal acquisition and processing. The aim of this study was to review the current state of sEMG utilization to assess transfemoral amputees, the procedures adopted for the acquisition and the functional findings. Methods: This is a literature review. Five electronic databases were searched to find the studies: All relevant information of each study was extracted and registered. Methodological quality was evaluated using a customized checklist. Results: Eight studies followed the inclusion criteria and were included in this paper. Four studies did not reach more than 80% of the quality checklist, few studies fully described the methodology applied. The muscles assessed were similar in all studies, electrodes placement was determined by different criteria. Conclusion: This paper demonstrates that a few studies have used this method to assess this population and the main variable aspect is concerned to the placement of the electrodes. More researches are needed to better understand the neuromuscular behavior of amputees by using sEMG and assist future researches to develop more reproducible and reliable studies. |
id |
UNB_c66c952045fba7e0d8c627709258d3a9 |
---|---|
oai_identifier_str |
oai:repositorio.unb.br:10482/36594 |
network_acronym_str |
UNB |
network_name_str |
Repositório Institucional da UnB |
repository_id_str |
|
spelling |
The use of surface electromyography to assess transfemoral amputees : methodological and functional perspectiveEletromiografiaAmputadosAim: Surface electromyography (sEMG) has been established as a safe non-invasive method to investigate neuromuscular function. However, the use of this instrument to assess lower limbs of transfemoral amputees still presents a lack of standardization in its methods of signal acquisition and processing. The aim of this study was to review the current state of sEMG utilization to assess transfemoral amputees, the procedures adopted for the acquisition and the functional findings. Methods: This is a literature review. Five electronic databases were searched to find the studies: All relevant information of each study was extracted and registered. Methodological quality was evaluated using a customized checklist. Results: Eight studies followed the inclusion criteria and were included in this paper. Four studies did not reach more than 80% of the quality checklist, few studies fully described the methodology applied. The muscles assessed were similar in all studies, electrodes placement was determined by different criteria. Conclusion: This paper demonstrates that a few studies have used this method to assess this population and the main variable aspect is concerned to the placement of the electrodes. More researches are needed to better understand the neuromuscular behavior of amputees by using sEMG and assist future researches to develop more reproducible and reliable studies.Faculdade UnB Gama (FGA)Universidade Estadual Paulista2020-01-24T10:32:11Z2020-01-24T10:32:11Z2019info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfSILVA, Rafaella Carvalho da; ZOCCOLI, Thanyze Alice Vicentini; MARÃES, Vera Regina Fernandes da Silva. The use of surface electromyography to assess transfemoral amputees: methodological and functional perspective. Motriz: Revista de Educação Física, v. 25, n. 3, e101995, 2019. Disponível em: http://scielo.br/scielo.php?script=sci_arttext&pid=S1980-65742019000300310. DOI: https://doi.org/10.1590/s1980-6574201900030012. Acesso em: 23 jan. 2020.https://repositorio.unb.br/handle/10482/36594https://doi.org/10.1590/s1980-6574201900030012http://orcid.org/0000-0001-7974-8166http://orcid.org/0000-0002-8193-300Xhttp://orcid.org/0000-0002-8895-9624(CC BY) - Under a license Creative Commons - Version 4.0info:eu-repo/semantics/openAccessSilva, Rafaella Carvalho daZoccoli, Thanyze Alice VicentiniMarães, Vera Regina Fernandes da Silvaengreponame:Repositório Institucional da UnBinstname:Universidade de Brasília (UnB)instacron:UNB2023-08-21T18:28:29Zoai:repositorio.unb.br:10482/36594Repositório InstitucionalPUBhttps://repositorio.unb.br/oai/requestrepositorio@unb.bropendoar:2023-08-21T18:28:29Repositório Institucional da UnB - Universidade de Brasília (UnB)false |
dc.title.none.fl_str_mv |
The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective |
title |
The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective |
spellingShingle |
The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective Silva, Rafaella Carvalho da Eletromiografia Amputados |
title_short |
The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective |
title_full |
The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective |
title_fullStr |
The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective |
title_full_unstemmed |
The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective |
title_sort |
The use of surface electromyography to assess transfemoral amputees : methodological and functional perspective |
author |
Silva, Rafaella Carvalho da |
author_facet |
Silva, Rafaella Carvalho da Zoccoli, Thanyze Alice Vicentini Marães, Vera Regina Fernandes da Silva |
author_role |
author |
author2 |
Zoccoli, Thanyze Alice Vicentini Marães, Vera Regina Fernandes da Silva |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Silva, Rafaella Carvalho da Zoccoli, Thanyze Alice Vicentini Marães, Vera Regina Fernandes da Silva |
dc.subject.por.fl_str_mv |
Eletromiografia Amputados |
topic |
Eletromiografia Amputados |
description |
Aim: Surface electromyography (sEMG) has been established as a safe non-invasive method to investigate neuromuscular function. However, the use of this instrument to assess lower limbs of transfemoral amputees still presents a lack of standardization in its methods of signal acquisition and processing. The aim of this study was to review the current state of sEMG utilization to assess transfemoral amputees, the procedures adopted for the acquisition and the functional findings. Methods: This is a literature review. Five electronic databases were searched to find the studies: All relevant information of each study was extracted and registered. Methodological quality was evaluated using a customized checklist. Results: Eight studies followed the inclusion criteria and were included in this paper. Four studies did not reach more than 80% of the quality checklist, few studies fully described the methodology applied. The muscles assessed were similar in all studies, electrodes placement was determined by different criteria. Conclusion: This paper demonstrates that a few studies have used this method to assess this population and the main variable aspect is concerned to the placement of the electrodes. More researches are needed to better understand the neuromuscular behavior of amputees by using sEMG and assist future researches to develop more reproducible and reliable studies. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019 2020-01-24T10:32:11Z 2020-01-24T10:32:11Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
SILVA, Rafaella Carvalho da; ZOCCOLI, Thanyze Alice Vicentini; MARÃES, Vera Regina Fernandes da Silva. The use of surface electromyography to assess transfemoral amputees: methodological and functional perspective. Motriz: Revista de Educação Física, v. 25, n. 3, e101995, 2019. Disponível em: http://scielo.br/scielo.php?script=sci_arttext&pid=S1980-65742019000300310. DOI: https://doi.org/10.1590/s1980-6574201900030012. Acesso em: 23 jan. 2020. https://repositorio.unb.br/handle/10482/36594 https://doi.org/10.1590/s1980-6574201900030012 http://orcid.org/0000-0001-7974-8166 http://orcid.org/0000-0002-8193-300X http://orcid.org/0000-0002-8895-9624 |
identifier_str_mv |
SILVA, Rafaella Carvalho da; ZOCCOLI, Thanyze Alice Vicentini; MARÃES, Vera Regina Fernandes da Silva. The use of surface electromyography to assess transfemoral amputees: methodological and functional perspective. Motriz: Revista de Educação Física, v. 25, n. 3, e101995, 2019. Disponível em: http://scielo.br/scielo.php?script=sci_arttext&pid=S1980-65742019000300310. DOI: https://doi.org/10.1590/s1980-6574201900030012. Acesso em: 23 jan. 2020. |
url |
https://repositorio.unb.br/handle/10482/36594 https://doi.org/10.1590/s1980-6574201900030012 http://orcid.org/0000-0001-7974-8166 http://orcid.org/0000-0002-8193-300X http://orcid.org/0000-0002-8895-9624 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
(CC BY) - Under a license Creative Commons - Version 4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
(CC BY) - Under a license Creative Commons - Version 4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual Paulista |
publisher.none.fl_str_mv |
Universidade Estadual Paulista |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UnB instname:Universidade de Brasília (UnB) instacron:UNB |
instname_str |
Universidade de Brasília (UnB) |
instacron_str |
UNB |
institution |
UNB |
reponame_str |
Repositório Institucional da UnB |
collection |
Repositório Institucional da UnB |
repository.name.fl_str_mv |
Repositório Institucional da UnB - Universidade de Brasília (UnB) |
repository.mail.fl_str_mv |
repositorio@unb.br |
_version_ |
1814508190064181248 |