Evaluation of flow and filling of root canal sealers using different methodologies

Detalhes bibliográficos
Autor(a) principal: TORRES,Fernanda Ferrari Esteves
Data de Publicação: 2019
Outros Autores: GUERREIRO-TANOMARU,Juliane Maria, PINTO,Jader Camilo, BONETTI-FILHO,Idomeo, TANOMARU-FILHO,Mário
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista de Odontologia da UNESP
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772019000100452
Resumo: Abstract Introduction Flow and filling ability of root canal sealers are indispensable for hermetic sealing of the root canal. Micro-computed tomography (micro-CT) can be used as a complementary methodology to evaluate such properties. Objective To evaluate the flow and filling ability of AH Plus, Endofill and Sealapex by conventional methodology and micro-CT. Material and method The flow of the sealers was analyzed according to ISO 6876/2012 and complemented by the area evaluation. Glass plates were manufactured with diameters of 1×1×2 mm and 1×1×1 mm (length, width and height), with a central cavity and four grooves in the horizontal and vertical directions. Each material was placed in the central cavity. Another glass plate and a metal weight were placed on the cement and kept for 10 minutes. The glass plate/sealer set was scanned using micro-CT. The flow was calculated by linear measurement of the material in the grooves. The central filling (mm3) was calculated in the central cavity and the lateral filling was measured up to 2 mm from the central cavity. Data were submitted to ANOVA/Tukey tests (α=0.05). Result All evaluated sealers presented flow according to ISO 6876 standards. The materials showed central cavity filling capacity higher than 80% and lateral filling greater than 75%. There was no difference in flow (mm and mm2) and in the filling ability (mm3) provided by the materials (p>0.05). Conclusion All evaluated root canal sealers showed adequate flow and filling capacity, suggesting their clinical application.
id UNESP-16_3d60e8006807e3e41cff075266c4143c
oai_identifier_str oai:scielo:S1807-25772019000100452
network_acronym_str UNESP-16
network_name_str Revista de Odontologia da UNESP
repository_id_str
spelling Evaluation of flow and filling of root canal sealers using different methodologiesEndodonticsdental materialsX-ray microtomographyAbstract Introduction Flow and filling ability of root canal sealers are indispensable for hermetic sealing of the root canal. Micro-computed tomography (micro-CT) can be used as a complementary methodology to evaluate such properties. Objective To evaluate the flow and filling ability of AH Plus, Endofill and Sealapex by conventional methodology and micro-CT. Material and method The flow of the sealers was analyzed according to ISO 6876/2012 and complemented by the area evaluation. Glass plates were manufactured with diameters of 1×1×2 mm and 1×1×1 mm (length, width and height), with a central cavity and four grooves in the horizontal and vertical directions. Each material was placed in the central cavity. Another glass plate and a metal weight were placed on the cement and kept for 10 minutes. The glass plate/sealer set was scanned using micro-CT. The flow was calculated by linear measurement of the material in the grooves. The central filling (mm3) was calculated in the central cavity and the lateral filling was measured up to 2 mm from the central cavity. Data were submitted to ANOVA/Tukey tests (α=0.05). Result All evaluated sealers presented flow according to ISO 6876 standards. The materials showed central cavity filling capacity higher than 80% and lateral filling greater than 75%. There was no difference in flow (mm and mm2) and in the filling ability (mm3) provided by the materials (p>0.05). Conclusion All evaluated root canal sealers showed adequate flow and filling capacity, suggesting their clinical application.Universidade Estadual Paulista Júlio de Mesquita Filho2019-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772019000100452Revista de Odontologia da UNESP v.48 2019reponame:Revista de Odontologia da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESP10.1590/1807-2577.11219info:eu-repo/semantics/openAccessTORRES,Fernanda Ferrari EstevesGUERREIRO-TANOMARU,Juliane MariaPINTO,Jader CamiloBONETTI-FILHO,IdomeoTANOMARU-FILHO,Márioeng2020-02-07T00:00:00Zoai:scielo:S1807-25772019000100452Revistahttps://www.revodontolunesp.com.br/PUBhttps://old.scielo.br/oai/scielo-oai.php||adriana@foar.unesp.br1807-25770101-1774opendoar:2020-02-07T00:00Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Evaluation of flow and filling of root canal sealers using different methodologies
title Evaluation of flow and filling of root canal sealers using different methodologies
spellingShingle Evaluation of flow and filling of root canal sealers using different methodologies
TORRES,Fernanda Ferrari Esteves
Endodontics
dental materials
X-ray microtomography
title_short Evaluation of flow and filling of root canal sealers using different methodologies
title_full Evaluation of flow and filling of root canal sealers using different methodologies
title_fullStr Evaluation of flow and filling of root canal sealers using different methodologies
title_full_unstemmed Evaluation of flow and filling of root canal sealers using different methodologies
title_sort Evaluation of flow and filling of root canal sealers using different methodologies
author TORRES,Fernanda Ferrari Esteves
author_facet TORRES,Fernanda Ferrari Esteves
GUERREIRO-TANOMARU,Juliane Maria
PINTO,Jader Camilo
BONETTI-FILHO,Idomeo
TANOMARU-FILHO,Mário
author_role author
author2 GUERREIRO-TANOMARU,Juliane Maria
PINTO,Jader Camilo
BONETTI-FILHO,Idomeo
TANOMARU-FILHO,Mário
author2_role author
author
author
author
dc.contributor.author.fl_str_mv TORRES,Fernanda Ferrari Esteves
GUERREIRO-TANOMARU,Juliane Maria
PINTO,Jader Camilo
BONETTI-FILHO,Idomeo
TANOMARU-FILHO,Mário
dc.subject.por.fl_str_mv Endodontics
dental materials
X-ray microtomography
topic Endodontics
dental materials
X-ray microtomography
description Abstract Introduction Flow and filling ability of root canal sealers are indispensable for hermetic sealing of the root canal. Micro-computed tomography (micro-CT) can be used as a complementary methodology to evaluate such properties. Objective To evaluate the flow and filling ability of AH Plus, Endofill and Sealapex by conventional methodology and micro-CT. Material and method The flow of the sealers was analyzed according to ISO 6876/2012 and complemented by the area evaluation. Glass plates were manufactured with diameters of 1×1×2 mm and 1×1×1 mm (length, width and height), with a central cavity and four grooves in the horizontal and vertical directions. Each material was placed in the central cavity. Another glass plate and a metal weight were placed on the cement and kept for 10 minutes. The glass plate/sealer set was scanned using micro-CT. The flow was calculated by linear measurement of the material in the grooves. The central filling (mm3) was calculated in the central cavity and the lateral filling was measured up to 2 mm from the central cavity. Data were submitted to ANOVA/Tukey tests (α=0.05). Result All evaluated sealers presented flow according to ISO 6876 standards. The materials showed central cavity filling capacity higher than 80% and lateral filling greater than 75%. There was no difference in flow (mm and mm2) and in the filling ability (mm3) provided by the materials (p>0.05). Conclusion All evaluated root canal sealers showed adequate flow and filling capacity, suggesting their clinical application.
publishDate 2019
dc.date.none.fl_str_mv 2019-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772019000100452
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772019000100452
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1807-2577.11219
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Universidade Estadual Paulista Júlio de Mesquita Filho
publisher.none.fl_str_mv Universidade Estadual Paulista Júlio de Mesquita Filho
dc.source.none.fl_str_mv Revista de Odontologia da UNESP v.48 2019
reponame:Revista de Odontologia da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Revista de Odontologia da UNESP
collection Revista de Odontologia da UNESP
repository.name.fl_str_mv Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv ||adriana@foar.unesp.br
_version_ 1748958561142046720