The acrylic's design or the addition of internal orthodontic wire changes the resistance of orthodontic plates?
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista de Odontologia da UNESP |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772013000600010 |
Resumo: | OBJECTIVE: Evaluate resistance of Hawley retainers in three different acrylic configurations in order to evaluate if its format or the addition of internal wire interferes in its resistance. MATERIAL AND METHOD: 45 Hawley retainers were fabricated, divided into three groups (n = 15): Group 1 - acrylic covering the entire hard palate, Group 2 - plate with relief at the deepest region of the palate, leaving it with a "U" conformation and Group 3 - similar to Group 2, with the addition of 0.7mm wire 2cm internally of the acrylic at the region of the palatine ridges. The compressive strength was tested in a universal mechanical testing machine (Stable Microsystems, London, United Kingdom), measuring the applied force until plate rupture occurred. The differences between the formats being compared by the Kruskal-Wallis test. The significance level was set at 5% (α = 0.05). RESULT: Group 1 showed the highest resistance, with a mean of about five times higher than Group 2 and three times higher than Group 3. CONCLUSION: acrylic reduction in dental retainer plates is directly related to the reduction of its compressive strength, the inclusion of orthodontic wire inside the acrylic increases the resistance of the plate, being a good alternative when more comfort is wanted for the patient without loss of the mechanical characteristics of the dental retainers. |
id |
UNESP-16_8752898ce114f8b5a15e8da9d940479a |
---|---|
oai_identifier_str |
oai:scielo:S1807-25772013000600010 |
network_acronym_str |
UNESP-16 |
network_name_str |
Revista de Odontologia da UNESP |
repository_id_str |
|
spelling |
The acrylic's design or the addition of internal orthodontic wire changes the resistance of orthodontic plates?Orthodontic appliance designorthodonticsmalocclusionOBJECTIVE: Evaluate resistance of Hawley retainers in three different acrylic configurations in order to evaluate if its format or the addition of internal wire interferes in its resistance. MATERIAL AND METHOD: 45 Hawley retainers were fabricated, divided into three groups (n = 15): Group 1 - acrylic covering the entire hard palate, Group 2 - plate with relief at the deepest region of the palate, leaving it with a "U" conformation and Group 3 - similar to Group 2, with the addition of 0.7mm wire 2cm internally of the acrylic at the region of the palatine ridges. The compressive strength was tested in a universal mechanical testing machine (Stable Microsystems, London, United Kingdom), measuring the applied force until plate rupture occurred. The differences between the formats being compared by the Kruskal-Wallis test. The significance level was set at 5% (α = 0.05). RESULT: Group 1 showed the highest resistance, with a mean of about five times higher than Group 2 and three times higher than Group 3. CONCLUSION: acrylic reduction in dental retainer plates is directly related to the reduction of its compressive strength, the inclusion of orthodontic wire inside the acrylic increases the resistance of the plate, being a good alternative when more comfort is wanted for the patient without loss of the mechanical characteristics of the dental retainers.Universidade Estadual Paulista Júlio de Mesquita Filho2013-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772013000600010Revista de Odontologia da UNESP v.42 n.6 2013reponame:Revista de Odontologia da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESP10.1590/S1807-25772013000600010info:eu-repo/semantics/openAccessPithon,Matheus MeloSousa,Érica Luiza Santana MoreiraFogaça,Davi Novaes LadeiaSilva,William Soares daRodrigues,Luciano BritoCoqueiro,Raildo Silvaeng2013-12-13T00:00:00Zoai:scielo:S1807-25772013000600010Revistahttps://www.revodontolunesp.com.br/PUBhttps://old.scielo.br/oai/scielo-oai.php||adriana@foar.unesp.br1807-25770101-1774opendoar:2013-12-13T00:00Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
The acrylic's design or the addition of internal orthodontic wire changes the resistance of orthodontic plates? |
title |
The acrylic's design or the addition of internal orthodontic wire changes the resistance of orthodontic plates? |
spellingShingle |
The acrylic's design or the addition of internal orthodontic wire changes the resistance of orthodontic plates? Pithon,Matheus Melo Orthodontic appliance design orthodontics malocclusion |
title_short |
The acrylic's design or the addition of internal orthodontic wire changes the resistance of orthodontic plates? |
title_full |
The acrylic's design or the addition of internal orthodontic wire changes the resistance of orthodontic plates? |
title_fullStr |
The acrylic's design or the addition of internal orthodontic wire changes the resistance of orthodontic plates? |
title_full_unstemmed |
The acrylic's design or the addition of internal orthodontic wire changes the resistance of orthodontic plates? |
title_sort |
The acrylic's design or the addition of internal orthodontic wire changes the resistance of orthodontic plates? |
author |
Pithon,Matheus Melo |
author_facet |
Pithon,Matheus Melo Sousa,Érica Luiza Santana Moreira Fogaça,Davi Novaes Ladeia Silva,William Soares da Rodrigues,Luciano Brito Coqueiro,Raildo Silva |
author_role |
author |
author2 |
Sousa,Érica Luiza Santana Moreira Fogaça,Davi Novaes Ladeia Silva,William Soares da Rodrigues,Luciano Brito Coqueiro,Raildo Silva |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Pithon,Matheus Melo Sousa,Érica Luiza Santana Moreira Fogaça,Davi Novaes Ladeia Silva,William Soares da Rodrigues,Luciano Brito Coqueiro,Raildo Silva |
dc.subject.por.fl_str_mv |
Orthodontic appliance design orthodontics malocclusion |
topic |
Orthodontic appliance design orthodontics malocclusion |
description |
OBJECTIVE: Evaluate resistance of Hawley retainers in three different acrylic configurations in order to evaluate if its format or the addition of internal wire interferes in its resistance. MATERIAL AND METHOD: 45 Hawley retainers were fabricated, divided into three groups (n = 15): Group 1 - acrylic covering the entire hard palate, Group 2 - plate with relief at the deepest region of the palate, leaving it with a "U" conformation and Group 3 - similar to Group 2, with the addition of 0.7mm wire 2cm internally of the acrylic at the region of the palatine ridges. The compressive strength was tested in a universal mechanical testing machine (Stable Microsystems, London, United Kingdom), measuring the applied force until plate rupture occurred. The differences between the formats being compared by the Kruskal-Wallis test. The significance level was set at 5% (α = 0.05). RESULT: Group 1 showed the highest resistance, with a mean of about five times higher than Group 2 and three times higher than Group 3. CONCLUSION: acrylic reduction in dental retainer plates is directly related to the reduction of its compressive strength, the inclusion of orthodontic wire inside the acrylic increases the resistance of the plate, being a good alternative when more comfort is wanted for the patient without loss of the mechanical characteristics of the dental retainers. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772013000600010 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772013000600010 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1807-25772013000600010 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Universidade Estadual Paulista Júlio de Mesquita Filho |
publisher.none.fl_str_mv |
Universidade Estadual Paulista Júlio de Mesquita Filho |
dc.source.none.fl_str_mv |
Revista de Odontologia da UNESP v.42 n.6 2013 reponame:Revista de Odontologia da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Revista de Odontologia da UNESP |
collection |
Revista de Odontologia da UNESP |
repository.name.fl_str_mv |
Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
||adriana@foar.unesp.br |
_version_ |
1748958558519558144 |