Biomechanical development and evaluation of a new framework for all-on-four rehabilitation

Detalhes bibliográficos
Autor(a) principal: SILVA,Vanessa Araujo
Data de Publicação: 2019
Outros Autores: FONSECA,Allyson Henrique de Andrade, FONSECA,Dimitri Ribas, SERAIDARIAN,Paulo Isaías
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista de Odontologia da UNESP
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772019000100412
Resumo: Abstract Introduction For complete rehabilitation of fully edentulous mandibles, the option for immediate loading determines the use of temporary prostheses that splint the installed implants. Although temporary prostheses with reinforcement provide rehabilitations with biomechanical benefits, the non-adoption of this recommendation coexists in different studies on immediate restorations. Objective This study evaluates a type of prosthesis to restore jaws by the all-on-four concept. Material and method: The mechanical behavior of prostheses with the modified framework was evaluated in vitro, under a cantilever mechanical unilateral bending test. Two representative groups were included in the all-on-four concept, with a G1 test group (n = 10) containing modified frameworks and a G2 control group (n = 10) that included full acrylic prostheses. The samples were submitted to thermal cycling with 500 cycles (5° ± 2 °C for 30 s, and 55° ± 2° for 30 s) and to the mechanical bending test on the cantilever. Result The Mann-Whitney test revealed a significant difference between G1 and G2 (p <0.001). In the descriptive evaluation, G1 averaged 830.50 N until the initial resin fracture, while the control group presented a mean of 403.58N. The maximum resistance until complete fracture was recorded in G1, with a mean of 903.03N, while in G2, a mean of 435.20N was recorded. The linear vertical component of the flexion was 0.68 mm and 0.39 mm until the initial fracture of the bar, respectively for G1 and G2. Conclusion The modified framework for the all-on-four protocol determined better mechanical performance when compared to the same full acrylic prosthesis model.
id UNESP-16_f83f6f9e979a028141b9dd3e379c0a5b
oai_identifier_str oai:scielo:S1807-25772019000100412
network_acronym_str UNESP-16
network_name_str Revista de Odontologia da UNESP
repository_id_str
spelling Biomechanical development and evaluation of a new framework for all-on-four rehabilitationImmediate loading on dental implantmandibleframeworkdental implantsAbstract Introduction For complete rehabilitation of fully edentulous mandibles, the option for immediate loading determines the use of temporary prostheses that splint the installed implants. Although temporary prostheses with reinforcement provide rehabilitations with biomechanical benefits, the non-adoption of this recommendation coexists in different studies on immediate restorations. Objective This study evaluates a type of prosthesis to restore jaws by the all-on-four concept. Material and method: The mechanical behavior of prostheses with the modified framework was evaluated in vitro, under a cantilever mechanical unilateral bending test. Two representative groups were included in the all-on-four concept, with a G1 test group (n = 10) containing modified frameworks and a G2 control group (n = 10) that included full acrylic prostheses. The samples were submitted to thermal cycling with 500 cycles (5° ± 2 °C for 30 s, and 55° ± 2° for 30 s) and to the mechanical bending test on the cantilever. Result The Mann-Whitney test revealed a significant difference between G1 and G2 (p <0.001). In the descriptive evaluation, G1 averaged 830.50 N until the initial resin fracture, while the control group presented a mean of 403.58N. The maximum resistance until complete fracture was recorded in G1, with a mean of 903.03N, while in G2, a mean of 435.20N was recorded. The linear vertical component of the flexion was 0.68 mm and 0.39 mm until the initial fracture of the bar, respectively for G1 and G2. Conclusion The modified framework for the all-on-four protocol determined better mechanical performance when compared to the same full acrylic prosthesis model.Universidade Estadual Paulista Júlio de Mesquita Filho2019-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772019000100412Revista de Odontologia da UNESP v.48 2019reponame:Revista de Odontologia da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESP10.1590/1807-2577.12318info:eu-repo/semantics/openAccessSILVA,Vanessa AraujoFONSECA,Allyson Henrique de AndradeFONSECA,Dimitri RibasSERAIDARIAN,Paulo Isaíaseng2019-07-24T00:00:00Zoai:scielo:S1807-25772019000100412Revistahttps://www.revodontolunesp.com.br/PUBhttps://old.scielo.br/oai/scielo-oai.php||adriana@foar.unesp.br1807-25770101-1774opendoar:2019-07-24T00:00Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Biomechanical development and evaluation of a new framework for all-on-four rehabilitation
title Biomechanical development and evaluation of a new framework for all-on-four rehabilitation
spellingShingle Biomechanical development and evaluation of a new framework for all-on-four rehabilitation
SILVA,Vanessa Araujo
Immediate loading on dental implant
mandible
framework
dental implants
title_short Biomechanical development and evaluation of a new framework for all-on-four rehabilitation
title_full Biomechanical development and evaluation of a new framework for all-on-four rehabilitation
title_fullStr Biomechanical development and evaluation of a new framework for all-on-four rehabilitation
title_full_unstemmed Biomechanical development and evaluation of a new framework for all-on-four rehabilitation
title_sort Biomechanical development and evaluation of a new framework for all-on-four rehabilitation
author SILVA,Vanessa Araujo
author_facet SILVA,Vanessa Araujo
FONSECA,Allyson Henrique de Andrade
FONSECA,Dimitri Ribas
SERAIDARIAN,Paulo Isaías
author_role author
author2 FONSECA,Allyson Henrique de Andrade
FONSECA,Dimitri Ribas
SERAIDARIAN,Paulo Isaías
author2_role author
author
author
dc.contributor.author.fl_str_mv SILVA,Vanessa Araujo
FONSECA,Allyson Henrique de Andrade
FONSECA,Dimitri Ribas
SERAIDARIAN,Paulo Isaías
dc.subject.por.fl_str_mv Immediate loading on dental implant
mandible
framework
dental implants
topic Immediate loading on dental implant
mandible
framework
dental implants
description Abstract Introduction For complete rehabilitation of fully edentulous mandibles, the option for immediate loading determines the use of temporary prostheses that splint the installed implants. Although temporary prostheses with reinforcement provide rehabilitations with biomechanical benefits, the non-adoption of this recommendation coexists in different studies on immediate restorations. Objective This study evaluates a type of prosthesis to restore jaws by the all-on-four concept. Material and method: The mechanical behavior of prostheses with the modified framework was evaluated in vitro, under a cantilever mechanical unilateral bending test. Two representative groups were included in the all-on-four concept, with a G1 test group (n = 10) containing modified frameworks and a G2 control group (n = 10) that included full acrylic prostheses. The samples were submitted to thermal cycling with 500 cycles (5° ± 2 °C for 30 s, and 55° ± 2° for 30 s) and to the mechanical bending test on the cantilever. Result The Mann-Whitney test revealed a significant difference between G1 and G2 (p <0.001). In the descriptive evaluation, G1 averaged 830.50 N until the initial resin fracture, while the control group presented a mean of 403.58N. The maximum resistance until complete fracture was recorded in G1, with a mean of 903.03N, while in G2, a mean of 435.20N was recorded. The linear vertical component of the flexion was 0.68 mm and 0.39 mm until the initial fracture of the bar, respectively for G1 and G2. Conclusion The modified framework for the all-on-four protocol determined better mechanical performance when compared to the same full acrylic prosthesis model.
publishDate 2019
dc.date.none.fl_str_mv 2019-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772019000100412
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772019000100412
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1807-2577.12318
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Universidade Estadual Paulista Júlio de Mesquita Filho
publisher.none.fl_str_mv Universidade Estadual Paulista Júlio de Mesquita Filho
dc.source.none.fl_str_mv Revista de Odontologia da UNESP v.48 2019
reponame:Revista de Odontologia da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Revista de Odontologia da UNESP
collection Revista de Odontologia da UNESP
repository.name.fl_str_mv Revista de Odontologia da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv ||adriana@foar.unesp.br
_version_ 1748958560859979776