Effect of an experimental fatigue protocol applied to the quadriceps femoris muscle of physically active persons
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Motriz (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-65742019000400306 |
Resumo: | Abstract Aims: The purpose of this study was to test an experimental fatigue protocol for the knee joint extensor muscles performed on an isokinetic dynamometer. Method: SPIRIT recommendations were applied. Participants were 40 healthy, young men and women. Protocol: The pre-fatigue quadriceps femoris peak torque during concentric maximum voluntary contractions (MVC) at 60º/s was measured. During the first protocol part, the task was to do MVC at 60°/s until a sequence of five concentric MVC was below 40% of its initial value. For the second part, intermittent quadriceps femoris muscle and hamstrings maximum voluntary isometric contractions for 30 s (ratio 2/1 seconds). Thirty seconds after the isometric MVC (post-fatigue), they did three concentric MVC. Then, after 5 minutes of absolute rest, they did two concentric MVC. Men and women showed a lower peak torque due to this protocol (p < 0.001). Conclusion: This protocol was effective for fatigue men and women’s quadriceps femoris muscle. |
id |
UNESP-17_c7a90d569b77cc4c92ead3ac57804c92 |
---|---|
oai_identifier_str |
oai:scielo:S1980-65742019000400306 |
network_acronym_str |
UNESP-17 |
network_name_str |
Motriz (Online) |
repository_id_str |
|
spelling |
Effect of an experimental fatigue protocol applied to the quadriceps femoris muscle of physically active personsbiomechanicsmuscle fatigueisokinetic dynamometerkneeAbstract Aims: The purpose of this study was to test an experimental fatigue protocol for the knee joint extensor muscles performed on an isokinetic dynamometer. Method: SPIRIT recommendations were applied. Participants were 40 healthy, young men and women. Protocol: The pre-fatigue quadriceps femoris peak torque during concentric maximum voluntary contractions (MVC) at 60º/s was measured. During the first protocol part, the task was to do MVC at 60°/s until a sequence of five concentric MVC was below 40% of its initial value. For the second part, intermittent quadriceps femoris muscle and hamstrings maximum voluntary isometric contractions for 30 s (ratio 2/1 seconds). Thirty seconds after the isometric MVC (post-fatigue), they did three concentric MVC. Then, after 5 minutes of absolute rest, they did two concentric MVC. Men and women showed a lower peak torque due to this protocol (p < 0.001). Conclusion: This protocol was effective for fatigue men and women’s quadriceps femoris muscle.Universidade Estadual Paulista2019-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-65742019000400306Motriz: Revista de Educação Física v.25 n.4 2019reponame:Motriz (Online)instname:Universidade Estadual Paulista (UNESP)instacron:UNESP10.1590/s1980-6574201900040109info:eu-repo/semantics/openAccessBersotti,Felipe MarreseMelo,Tamiris Barbosa deMochizuki,LuisSkau,Jerônimo Rafaeleng2019-12-16T00:00:00Zoai:scielo:S1980-65742019000400306Revistahttp://www.periodicos.rc.biblioteca.unesp.br/index.php/motrizPUBhttps://old.scielo.br/oai/scielo-oai.phpmotriz@rc.unesp.br||mauerber@rc.unesp.br||azanesco@rc.unesp.br1980-65741415-9805opendoar:2022-11-08T16:30:44.374997Motriz (Online) - Universidade Estadual Paulista (UNESP)true |
dc.title.none.fl_str_mv |
Effect of an experimental fatigue protocol applied to the quadriceps femoris muscle of physically active persons |
title |
Effect of an experimental fatigue protocol applied to the quadriceps femoris muscle of physically active persons |
spellingShingle |
Effect of an experimental fatigue protocol applied to the quadriceps femoris muscle of physically active persons Bersotti,Felipe Marrese biomechanics muscle fatigue isokinetic dynamometer knee |
title_short |
Effect of an experimental fatigue protocol applied to the quadriceps femoris muscle of physically active persons |
title_full |
Effect of an experimental fatigue protocol applied to the quadriceps femoris muscle of physically active persons |
title_fullStr |
Effect of an experimental fatigue protocol applied to the quadriceps femoris muscle of physically active persons |
title_full_unstemmed |
Effect of an experimental fatigue protocol applied to the quadriceps femoris muscle of physically active persons |
title_sort |
Effect of an experimental fatigue protocol applied to the quadriceps femoris muscle of physically active persons |
author |
Bersotti,Felipe Marrese |
author_facet |
Bersotti,Felipe Marrese Melo,Tamiris Barbosa de Mochizuki,Luis Skau,Jerônimo Rafael |
author_role |
author |
author2 |
Melo,Tamiris Barbosa de Mochizuki,Luis Skau,Jerônimo Rafael |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Bersotti,Felipe Marrese Melo,Tamiris Barbosa de Mochizuki,Luis Skau,Jerônimo Rafael |
dc.subject.por.fl_str_mv |
biomechanics muscle fatigue isokinetic dynamometer knee |
topic |
biomechanics muscle fatigue isokinetic dynamometer knee |
description |
Abstract Aims: The purpose of this study was to test an experimental fatigue protocol for the knee joint extensor muscles performed on an isokinetic dynamometer. Method: SPIRIT recommendations were applied. Participants were 40 healthy, young men and women. Protocol: The pre-fatigue quadriceps femoris peak torque during concentric maximum voluntary contractions (MVC) at 60º/s was measured. During the first protocol part, the task was to do MVC at 60°/s until a sequence of five concentric MVC was below 40% of its initial value. For the second part, intermittent quadriceps femoris muscle and hamstrings maximum voluntary isometric contractions for 30 s (ratio 2/1 seconds). Thirty seconds after the isometric MVC (post-fatigue), they did three concentric MVC. Then, after 5 minutes of absolute rest, they did two concentric MVC. Men and women showed a lower peak torque due to this protocol (p < 0.001). Conclusion: This protocol was effective for fatigue men and women’s quadriceps femoris muscle. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-65742019000400306 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-65742019000400306 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/s1980-6574201900040109 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Universidade Estadual Paulista |
publisher.none.fl_str_mv |
Universidade Estadual Paulista |
dc.source.none.fl_str_mv |
Motriz: Revista de Educação Física v.25 n.4 2019 reponame:Motriz (Online) instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Motriz (Online) |
collection |
Motriz (Online) |
repository.name.fl_str_mv |
Motriz (Online) - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
motriz@rc.unesp.br||mauerber@rc.unesp.br||azanesco@rc.unesp.br |
_version_ |
1788170936704303104 |