Influence of Preparation Design, Restorative Material and Load Direction on The Stress Distribution of Ceramic Veneer in Upper Central Incisor

Detalhes bibliográficos
Autor(a) principal: Meirelles , Laura Célia Fernandes
Data de Publicação: 2021
Outros Autores: Pierre, Fernanda Zapater, Tribst , João Paulo Mendes, Pagani , Clovis, Bresciani , Eduardo, Borges , Alexandre Luiz Souto
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Science
Texto Completo: https://ojs.ict.unesp.br/index.php/cob/article/view/2494
Resumo: Objective: Evaluate the effect of four preparation designs, two ceramic materials, and two occlusion contact types on the stress distribution of ceramic veneer in upper central incisor. Material and methods:  3D-models were performed in the modeling software containing enamel, dentin, pulp, periodontal ligament and a base of polyurethane resin. The designs were modeled and exported to the computer aided engineering software to perform the static structural analysis. For the mesh, a total of 155429 tetrahedron elements and 271683 nodes were used, after a 10% convergence test. Two materials, lithium disilicate and feldspathic ceramics, were simulated. A static load of 100 N on 45º was applied on the incisal and middle thirds of the palatal tooth region, guided by the occlusal plane. The base was constrained in all directions. The Maximum Principal Stress was the failure criteria chosen for the analysis. Results: The Finite Element Analysis showed that the most conservative designs presented less stress concentration on the ceramic veneer. However, the highest tensile stress concentrations were observed on lithium disilicate veneer with extend design, on the middle third. The type of occlusal contact presented different stress patterns among the preparation designs; the incisal contact showed higher stress concentration compared to middle third contact regardless the ceramic material. Conclusions: To perform a ceramic veneer in upper central incisor, the feldspathic ceramic presented promising results and should be recommended when the extended design was done. Regarding contact types, the incisal contact is more prone to failure regardless the ceramic and preparation design.   Keywords Ceramics; Dental veneers; Finite element analysis.
id UNESP-20_325d72e46e13d5286049320b831f3152
oai_identifier_str oai:ojs.pkp.sfu.ca:article/2494
network_acronym_str UNESP-20
network_name_str Brazilian Dental Science
repository_id_str
spelling Influence of Preparation Design, Restorative Material and Load Direction on The Stress Distribution of Ceramic Veneer in Upper Central IncisorObjective: Evaluate the effect of four preparation designs, two ceramic materials, and two occlusion contact types on the stress distribution of ceramic veneer in upper central incisor. Material and methods:  3D-models were performed in the modeling software containing enamel, dentin, pulp, periodontal ligament and a base of polyurethane resin. The designs were modeled and exported to the computer aided engineering software to perform the static structural analysis. For the mesh, a total of 155429 tetrahedron elements and 271683 nodes were used, after a 10% convergence test. Two materials, lithium disilicate and feldspathic ceramics, were simulated. A static load of 100 N on 45º was applied on the incisal and middle thirds of the palatal tooth region, guided by the occlusal plane. The base was constrained in all directions. The Maximum Principal Stress was the failure criteria chosen for the analysis. Results: The Finite Element Analysis showed that the most conservative designs presented less stress concentration on the ceramic veneer. However, the highest tensile stress concentrations were observed on lithium disilicate veneer with extend design, on the middle third. The type of occlusal contact presented different stress patterns among the preparation designs; the incisal contact showed higher stress concentration compared to middle third contact regardless the ceramic material. Conclusions: To perform a ceramic veneer in upper central incisor, the feldspathic ceramic presented promising results and should be recommended when the extended design was done. Regarding contact types, the incisal contact is more prone to failure regardless the ceramic and preparation design.   Keywords Ceramics; Dental veneers; Finite element analysis.Institute of Science and Technology of São José dos Campos2021-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ojs.ict.unesp.br/index.php/cob/article/view/249410.14295/bds.2021.v24i3.2494Brazilian Dental Science; Vol. 24 No. 3 (2021): Jul - Sep / 2021 - published Jul 2021Brazilian Dental Science; v. 24 n. 3 (2021): Jul - Sep / 2021 - published Jul 20212178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESPenghttps://ojs.ict.unesp.br/index.php/cob/article/view/2494/4365Copyright (c) 2021 Brazilian Dental Scienceinfo:eu-repo/semantics/openAccessMeirelles , Laura Célia Fernandes Pierre, Fernanda Zapater Tribst , João Paulo Mendes Pagani , Clovis Bresciani , Eduardo Borges , Alexandre Luiz Souto 2021-08-06T18:15:05Zoai:ojs.pkp.sfu.ca:article/2494Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2022-11-08T16:30:36.691758Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)true
dc.title.none.fl_str_mv Influence of Preparation Design, Restorative Material and Load Direction on The Stress Distribution of Ceramic Veneer in Upper Central Incisor
title Influence of Preparation Design, Restorative Material and Load Direction on The Stress Distribution of Ceramic Veneer in Upper Central Incisor
spellingShingle Influence of Preparation Design, Restorative Material and Load Direction on The Stress Distribution of Ceramic Veneer in Upper Central Incisor
Meirelles , Laura Célia Fernandes
title_short Influence of Preparation Design, Restorative Material and Load Direction on The Stress Distribution of Ceramic Veneer in Upper Central Incisor
title_full Influence of Preparation Design, Restorative Material and Load Direction on The Stress Distribution of Ceramic Veneer in Upper Central Incisor
title_fullStr Influence of Preparation Design, Restorative Material and Load Direction on The Stress Distribution of Ceramic Veneer in Upper Central Incisor
title_full_unstemmed Influence of Preparation Design, Restorative Material and Load Direction on The Stress Distribution of Ceramic Veneer in Upper Central Incisor
title_sort Influence of Preparation Design, Restorative Material and Load Direction on The Stress Distribution of Ceramic Veneer in Upper Central Incisor
author Meirelles , Laura Célia Fernandes
author_facet Meirelles , Laura Célia Fernandes
Pierre, Fernanda Zapater
Tribst , João Paulo Mendes
Pagani , Clovis
Bresciani , Eduardo
Borges , Alexandre Luiz Souto
author_role author
author2 Pierre, Fernanda Zapater
Tribst , João Paulo Mendes
Pagani , Clovis
Bresciani , Eduardo
Borges , Alexandre Luiz Souto
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Meirelles , Laura Célia Fernandes
Pierre, Fernanda Zapater
Tribst , João Paulo Mendes
Pagani , Clovis
Bresciani , Eduardo
Borges , Alexandre Luiz Souto
description Objective: Evaluate the effect of four preparation designs, two ceramic materials, and two occlusion contact types on the stress distribution of ceramic veneer in upper central incisor. Material and methods:  3D-models were performed in the modeling software containing enamel, dentin, pulp, periodontal ligament and a base of polyurethane resin. The designs were modeled and exported to the computer aided engineering software to perform the static structural analysis. For the mesh, a total of 155429 tetrahedron elements and 271683 nodes were used, after a 10% convergence test. Two materials, lithium disilicate and feldspathic ceramics, were simulated. A static load of 100 N on 45º was applied on the incisal and middle thirds of the palatal tooth region, guided by the occlusal plane. The base was constrained in all directions. The Maximum Principal Stress was the failure criteria chosen for the analysis. Results: The Finite Element Analysis showed that the most conservative designs presented less stress concentration on the ceramic veneer. However, the highest tensile stress concentrations were observed on lithium disilicate veneer with extend design, on the middle third. The type of occlusal contact presented different stress patterns among the preparation designs; the incisal contact showed higher stress concentration compared to middle third contact regardless the ceramic material. Conclusions: To perform a ceramic veneer in upper central incisor, the feldspathic ceramic presented promising results and should be recommended when the extended design was done. Regarding contact types, the incisal contact is more prone to failure regardless the ceramic and preparation design.   Keywords Ceramics; Dental veneers; Finite element analysis.
publishDate 2021
dc.date.none.fl_str_mv 2021-07-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://ojs.ict.unesp.br/index.php/cob/article/view/2494
10.14295/bds.2021.v24i3.2494
url https://ojs.ict.unesp.br/index.php/cob/article/view/2494
identifier_str_mv 10.14295/bds.2021.v24i3.2494
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://ojs.ict.unesp.br/index.php/cob/article/view/2494/4365
dc.rights.driver.fl_str_mv Copyright (c) 2021 Brazilian Dental Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2021 Brazilian Dental Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Institute of Science and Technology of São José dos Campos
publisher.none.fl_str_mv Institute of Science and Technology of São José dos Campos
dc.source.none.fl_str_mv Brazilian Dental Science; Vol. 24 No. 3 (2021): Jul - Sep / 2021 - published Jul 2021
Brazilian Dental Science; v. 24 n. 3 (2021): Jul - Sep / 2021 - published Jul 2021
2178-6011
reponame:Brazilian Dental Science
instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Brazilian Dental Science
collection Brazilian Dental Science
repository.name.fl_str_mv Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
repository.mail.fl_str_mv sergio@fosjc.unesp.br||sergio@fosjc.unesp.br
_version_ 1788346901934899200