Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis
Autor(a) principal: | |
---|---|
Data de Publicação: | 2024 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Science |
Texto Completo: | https://ojs.ict.unesp.br/index.php/cob/article/view/4154 |
Resumo: | Objective: The aim of this study was to evaluate the marginal gap of frameworks produced using the CAD-CAM system, from zirconia and lithium disilicate blocks, adapted to a tooth preparation and a gypsum die. Material and Methods: For this study, a human first molar tooth was used as a master model with a full crown preparation. It was molded 20 times to obtain the gypsum die and randomly divided into 2 groups (n=10) for the fabrication of zirconia and lithium disilicate frameworks. The frameworks were made using pre-sintered zirconia blocks and lithium disilicate blocks, both CAD-CAM systems. The marginal gap was measured in µm at four points (buccal, palatal, mesial, and distal) using a comparator microscope with 30x magnification, with the framework seated on the master model (tooth), and on the gypsum die. Marginal gap data (µm) were evaluated using two-way analysis of variance and Tukey’s test with a significance level of 5%. Results: The results showed that there was no statistically significant interaction between the factors studied (p=0.223) or isolated factors (ceramic factor p=0.886 and die factor p=0.786). Conclusion: Both ceramics produced using the CAD-CAM technique did not exhibit statistical differences in marginal adaptation on the two types of substrates, both on tooth preparation and on the gypsum die. KEYWORDS CAD-CAM; Dental ceramics; Dental prosthesis; Lithium disilicate; Marginal adaptation; Zirconia. |
id |
UNESP-20_72911d65eb9b591b200018e0624970c9 |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/4154 |
network_acronym_str |
UNESP-20 |
network_name_str |
Brazilian Dental Science |
repository_id_str |
|
spelling |
Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysisObjective: The aim of this study was to evaluate the marginal gap of frameworks produced using the CAD-CAM system, from zirconia and lithium disilicate blocks, adapted to a tooth preparation and a gypsum die. Material and Methods: For this study, a human first molar tooth was used as a master model with a full crown preparation. It was molded 20 times to obtain the gypsum die and randomly divided into 2 groups (n=10) for the fabrication of zirconia and lithium disilicate frameworks. The frameworks were made using pre-sintered zirconia blocks and lithium disilicate blocks, both CAD-CAM systems. The marginal gap was measured in µm at four points (buccal, palatal, mesial, and distal) using a comparator microscope with 30x magnification, with the framework seated on the master model (tooth), and on the gypsum die. Marginal gap data (µm) were evaluated using two-way analysis of variance and Tukey’s test with a significance level of 5%. Results: The results showed that there was no statistically significant interaction between the factors studied (p=0.223) or isolated factors (ceramic factor p=0.886 and die factor p=0.786). Conclusion: Both ceramics produced using the CAD-CAM technique did not exhibit statistical differences in marginal adaptation on the two types of substrates, both on tooth preparation and on the gypsum die. KEYWORDS CAD-CAM; Dental ceramics; Dental prosthesis; Lithium disilicate; Marginal adaptation; Zirconia.Institute of Science and Technology of São José dos Campos2024-05-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ojs.ict.unesp.br/index.php/cob/article/view/415410.4322/bds.2024.e4154Brazilian Dental Science; Vol. 27 No. 1 (2024): Jan - Mar / 2024 - Published Jan 2024Brazilian Dental Science; v. 27 n. 1 (2024): Jan - Mar / 2024 - Published Jan 20242178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPenghttps://ojs.ict.unesp.br/index.php/cob/article/view/4154/4716Copyright (c) 2024 Brazilian Dental Scienceinfo:eu-repo/semantics/openAccessAbreu, Ellen Christine Rodrigues Ferreira , Vicente ColussiOlivieri , Karina Andrea Novaes Brandt , William Cunha 2024-04-01T17:45:19Zoai:ojs.pkp.sfu.ca:article/4154Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2024-04-01T17:45:19Brazilian Dental Science - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis |
title |
Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis |
spellingShingle |
Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis Abreu, Ellen Christine Rodrigues |
title_short |
Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis |
title_full |
Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis |
title_fullStr |
Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis |
title_full_unstemmed |
Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis |
title_sort |
Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis |
author |
Abreu, Ellen Christine Rodrigues |
author_facet |
Abreu, Ellen Christine Rodrigues Ferreira , Vicente Colussi Olivieri , Karina Andrea Novaes Brandt , William Cunha |
author_role |
author |
author2 |
Ferreira , Vicente Colussi Olivieri , Karina Andrea Novaes Brandt , William Cunha |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Abreu, Ellen Christine Rodrigues Ferreira , Vicente Colussi Olivieri , Karina Andrea Novaes Brandt , William Cunha |
description |
Objective: The aim of this study was to evaluate the marginal gap of frameworks produced using the CAD-CAM system, from zirconia and lithium disilicate blocks, adapted to a tooth preparation and a gypsum die. Material and Methods: For this study, a human first molar tooth was used as a master model with a full crown preparation. It was molded 20 times to obtain the gypsum die and randomly divided into 2 groups (n=10) for the fabrication of zirconia and lithium disilicate frameworks. The frameworks were made using pre-sintered zirconia blocks and lithium disilicate blocks, both CAD-CAM systems. The marginal gap was measured in µm at four points (buccal, palatal, mesial, and distal) using a comparator microscope with 30x magnification, with the framework seated on the master model (tooth), and on the gypsum die. Marginal gap data (µm) were evaluated using two-way analysis of variance and Tukey’s test with a significance level of 5%. Results: The results showed that there was no statistically significant interaction between the factors studied (p=0.223) or isolated factors (ceramic factor p=0.886 and die factor p=0.786). Conclusion: Both ceramics produced using the CAD-CAM technique did not exhibit statistical differences in marginal adaptation on the two types of substrates, both on tooth preparation and on the gypsum die. KEYWORDS CAD-CAM; Dental ceramics; Dental prosthesis; Lithium disilicate; Marginal adaptation; Zirconia. |
publishDate |
2024 |
dc.date.none.fl_str_mv |
2024-05-15 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/4154 10.4322/bds.2024.e4154 |
url |
https://ojs.ict.unesp.br/index.php/cob/article/view/4154 |
identifier_str_mv |
10.4322/bds.2024.e4154 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/4154/4716 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2024 Brazilian Dental Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2024 Brazilian Dental Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
dc.source.none.fl_str_mv |
Brazilian Dental Science; Vol. 27 No. 1 (2024): Jan - Mar / 2024 - Published Jan 2024 Brazilian Dental Science; v. 27 n. 1 (2024): Jan - Mar / 2024 - Published Jan 2024 2178-6011 reponame:Brazilian Dental Science instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Brazilian Dental Science |
collection |
Brazilian Dental Science |
repository.name.fl_str_mv |
Brazilian Dental Science - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
sergio@fosjc.unesp.br||sergio@fosjc.unesp.br |
_version_ |
1800214394600161280 |