Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis

Detalhes bibliográficos
Autor(a) principal: Abreu, Ellen Christine Rodrigues
Data de Publicação: 2024
Outros Autores: Ferreira , Vicente Colussi, Olivieri , Karina Andrea Novaes, Brandt , William Cunha
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Science
Texto Completo: https://ojs.ict.unesp.br/index.php/cob/article/view/4154
Resumo: Objective: The aim of this study was to evaluate the marginal gap of frameworks produced using the CAD-CAM system, from zirconia and lithium disilicate blocks, adapted to a tooth preparation and a gypsum die. Material and Methods: For this study, a human first molar tooth was used as a master model with a full crown preparation. It was molded 20 times to obtain the gypsum die and randomly divided into 2 groups (n=10) for the fabrication of zirconia and lithium disilicate frameworks. The frameworks were made using pre-sintered zirconia blocks and lithium disilicate blocks, both CAD-CAM systems. The marginal gap was measured in µm at four points (buccal, palatal, mesial, and distal) using a comparator microscope with 30x magnification, with the framework seated on the master model (tooth), and on the gypsum die. Marginal gap data (µm) were evaluated using two-way analysis of variance and Tukey’s test with a significance level of 5%. Results: The results showed that there was no statistically significant interaction between the factors studied (p=0.223) or isolated factors (ceramic factor p=0.886 and die factor p=0.786). Conclusion: Both ceramics produced using the CAD-CAM technique did not exhibit statistical differences in marginal adaptation on the two types of substrates, both on tooth preparation and on the gypsum die. KEYWORDS CAD-CAM; Dental ceramics; Dental prosthesis; Lithium disilicate; Marginal adaptation; Zirconia.
id UNESP-20_72911d65eb9b591b200018e0624970c9
oai_identifier_str oai:ojs.pkp.sfu.ca:article/4154
network_acronym_str UNESP-20
network_name_str Brazilian Dental Science
repository_id_str
spelling Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysisObjective: The aim of this study was to evaluate the marginal gap of frameworks produced using the CAD-CAM system, from zirconia and lithium disilicate blocks, adapted to a tooth preparation and a gypsum die. Material and Methods: For this study, a human first molar tooth was used as a master model with a full crown preparation. It was molded 20 times to obtain the gypsum die and randomly divided into 2 groups (n=10) for the fabrication of zirconia and lithium disilicate frameworks. The frameworks were made using pre-sintered zirconia blocks and lithium disilicate blocks, both CAD-CAM systems. The marginal gap was measured in µm at four points (buccal, palatal, mesial, and distal) using a comparator microscope with 30x magnification, with the framework seated on the master model (tooth), and on the gypsum die. Marginal gap data (µm) were evaluated using two-way analysis of variance and Tukey’s test with a significance level of 5%. Results: The results showed that there was no statistically significant interaction between the factors studied (p=0.223) or isolated factors (ceramic factor p=0.886 and die factor p=0.786). Conclusion: Both ceramics produced using the CAD-CAM technique did not exhibit statistical differences in marginal adaptation on the two types of substrates, both on tooth preparation and on the gypsum die. KEYWORDS CAD-CAM; Dental ceramics; Dental prosthesis; Lithium disilicate; Marginal adaptation; Zirconia.Institute of Science and Technology of São José dos Campos2024-05-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ojs.ict.unesp.br/index.php/cob/article/view/415410.4322/bds.2024.e4154Brazilian Dental Science; Vol. 27 No. 1 (2024): Jan - Mar / 2024 - Published Jan 2024Brazilian Dental Science; v. 27 n. 1 (2024): Jan - Mar / 2024 - Published Jan 20242178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPenghttps://ojs.ict.unesp.br/index.php/cob/article/view/4154/4716Copyright (c) 2024 Brazilian Dental Scienceinfo:eu-repo/semantics/openAccessAbreu, Ellen Christine Rodrigues Ferreira , Vicente ColussiOlivieri , Karina Andrea Novaes Brandt , William Cunha 2024-04-01T17:45:19Zoai:ojs.pkp.sfu.ca:article/4154Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2024-04-01T17:45:19Brazilian Dental Science - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis
title Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis
spellingShingle Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis
Abreu, Ellen Christine Rodrigues
title_short Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis
title_full Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis
title_fullStr Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis
title_full_unstemmed Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis
title_sort Marginal gap of zirconia and lithium disilicate frameworks produced by the CAD-CAM technique through a comparator microscope – in vitro analysis
author Abreu, Ellen Christine Rodrigues
author_facet Abreu, Ellen Christine Rodrigues
Ferreira , Vicente Colussi
Olivieri , Karina Andrea Novaes
Brandt , William Cunha
author_role author
author2 Ferreira , Vicente Colussi
Olivieri , Karina Andrea Novaes
Brandt , William Cunha
author2_role author
author
author
dc.contributor.author.fl_str_mv Abreu, Ellen Christine Rodrigues
Ferreira , Vicente Colussi
Olivieri , Karina Andrea Novaes
Brandt , William Cunha
description Objective: The aim of this study was to evaluate the marginal gap of frameworks produced using the CAD-CAM system, from zirconia and lithium disilicate blocks, adapted to a tooth preparation and a gypsum die. Material and Methods: For this study, a human first molar tooth was used as a master model with a full crown preparation. It was molded 20 times to obtain the gypsum die and randomly divided into 2 groups (n=10) for the fabrication of zirconia and lithium disilicate frameworks. The frameworks were made using pre-sintered zirconia blocks and lithium disilicate blocks, both CAD-CAM systems. The marginal gap was measured in µm at four points (buccal, palatal, mesial, and distal) using a comparator microscope with 30x magnification, with the framework seated on the master model (tooth), and on the gypsum die. Marginal gap data (µm) were evaluated using two-way analysis of variance and Tukey’s test with a significance level of 5%. Results: The results showed that there was no statistically significant interaction between the factors studied (p=0.223) or isolated factors (ceramic factor p=0.886 and die factor p=0.786). Conclusion: Both ceramics produced using the CAD-CAM technique did not exhibit statistical differences in marginal adaptation on the two types of substrates, both on tooth preparation and on the gypsum die. KEYWORDS CAD-CAM; Dental ceramics; Dental prosthesis; Lithium disilicate; Marginal adaptation; Zirconia.
publishDate 2024
dc.date.none.fl_str_mv 2024-05-15
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://ojs.ict.unesp.br/index.php/cob/article/view/4154
10.4322/bds.2024.e4154
url https://ojs.ict.unesp.br/index.php/cob/article/view/4154
identifier_str_mv 10.4322/bds.2024.e4154
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://ojs.ict.unesp.br/index.php/cob/article/view/4154/4716
dc.rights.driver.fl_str_mv Copyright (c) 2024 Brazilian Dental Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2024 Brazilian Dental Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Institute of Science and Technology of São José dos Campos
publisher.none.fl_str_mv Institute of Science and Technology of São José dos Campos
dc.source.none.fl_str_mv Brazilian Dental Science; Vol. 27 No. 1 (2024): Jan - Mar / 2024 - Published Jan 2024
Brazilian Dental Science; v. 27 n. 1 (2024): Jan - Mar / 2024 - Published Jan 2024
2178-6011
reponame:Brazilian Dental Science
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Brazilian Dental Science
collection Brazilian Dental Science
repository.name.fl_str_mv Brazilian Dental Science - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv sergio@fosjc.unesp.br||sergio@fosjc.unesp.br
_version_ 1800214394600161280