Microtensile bond strength of a universal adhesive to deep dentin

Detalhes bibliográficos
Autor(a) principal: Gre, Cristina
Data de Publicação: 2016
Outros Autores: Amaral Caldeira de Andrada, MAuro, Monteiro Junior, Sylvio
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Science
Texto Completo: https://ojs.ict.unesp.br/index.php/cob/article/view/1259
Resumo: Objective: This study evaluated the microtensile bond strength of a universal adhesive system applied to deep dentin under different bonding strategies. Material and Methods: Fifteen human third molars had the coronal portion removed exposing deep dentin and were assigned into 3 groups according to the adhesive system: G1(control): 2-steps totaletch (Adper Single Bond 2, 3M ESPE); G2: 1-step self-etch universal adhesive (Scotchbond Universal, 3M ESPE); G3:2 steps total-etch universal adhesive (Scotchbond Universal, 3M ESPE). Composite buildups were performed on the dentin surfaces and after water storage for 24 h, teeth were sectioned to obtain 40 bonded beams per group with sectional area of 0.9 mm2 . The specimens were submitted to the microtensile bond strength (µTBS) test until failure. Statistical analyses were computed using one-way ANOVA (p = 0.05). Results: The mean µTBS (in MPa) were G1 = 22.27, G2 = 22.85 and G3 = 20.3. After statistical analysis, no significant differences were observed among the groups. Conclusions: Universal adhesive system performed similarly to the total-etch adhesive and was not affected by the adhesion strategy. KEYWORDS Microtensile; Adhesive system; Dentin.
id UNESP-20_91bdbc843cf48943d63fd57807903f3c
oai_identifier_str oai:ojs.pkp.sfu.ca:article/1259
network_acronym_str UNESP-20
network_name_str Brazilian Dental Science
repository_id_str
spelling Microtensile bond strength of a universal adhesive to deep dentinObjective: This study evaluated the microtensile bond strength of a universal adhesive system applied to deep dentin under different bonding strategies. Material and Methods: Fifteen human third molars had the coronal portion removed exposing deep dentin and were assigned into 3 groups according to the adhesive system: G1(control): 2-steps totaletch (Adper Single Bond 2, 3M ESPE); G2: 1-step self-etch universal adhesive (Scotchbond Universal, 3M ESPE); G3:2 steps total-etch universal adhesive (Scotchbond Universal, 3M ESPE). Composite buildups were performed on the dentin surfaces and after water storage for 24 h, teeth were sectioned to obtain 40 bonded beams per group with sectional area of 0.9 mm2 . The specimens were submitted to the microtensile bond strength (µTBS) test until failure. Statistical analyses were computed using one-way ANOVA (p = 0.05). Results: The mean µTBS (in MPa) were G1 = 22.27, G2 = 22.85 and G3 = 20.3. After statistical analysis, no significant differences were observed among the groups. Conclusions: Universal adhesive system performed similarly to the total-etch adhesive and was not affected by the adhesion strategy. KEYWORDS Microtensile; Adhesive system; Dentin.Institute of Science and Technology of São José dos Campos2016-07-07info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/vnd.openxmlformats-officedocument.wordprocessingml.documentapplication/vnd.openxmlformats-officedocument.wordprocessingml.documentapplication/vnd.openxmlformats-officedocument.wordprocessingml.documentapplication/vnd.openxmlformats-officedocument.wordprocessingml.documenthttps://ojs.ict.unesp.br/index.php/cob/article/view/125910.14295/bds.2016.v19i2.1259Brazilian Dental Science; Vol. 19 No. 2 (2016): Apr. - Jun. / 2016 - Published June 2016; 104-110Brazilian Dental Science; v. 19 n. 2 (2016): Apr. - Jun. / 2016 - Published June 2016; 104-1102178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESPenghttps://ojs.ict.unesp.br/index.php/cob/article/view/1259/1031https://ojs.ict.unesp.br/index.php/cob/article/view/1259/2646https://ojs.ict.unesp.br/index.php/cob/article/view/1259/2647https://ojs.ict.unesp.br/index.php/cob/article/view/1259/2648https://ojs.ict.unesp.br/index.php/cob/article/view/1259/2649Copyright (c) 2016 Brazilian Dental Scienceinfo:eu-repo/semantics/openAccessGre, CristinaAmaral Caldeira de Andrada, MAuroMonteiro Junior, Sylvio2020-01-28T12:21:28Zoai:ojs.pkp.sfu.ca:article/1259Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2022-11-08T16:30:06.366007Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)true
dc.title.none.fl_str_mv Microtensile bond strength of a universal adhesive to deep dentin
title Microtensile bond strength of a universal adhesive to deep dentin
spellingShingle Microtensile bond strength of a universal adhesive to deep dentin
Gre, Cristina
title_short Microtensile bond strength of a universal adhesive to deep dentin
title_full Microtensile bond strength of a universal adhesive to deep dentin
title_fullStr Microtensile bond strength of a universal adhesive to deep dentin
title_full_unstemmed Microtensile bond strength of a universal adhesive to deep dentin
title_sort Microtensile bond strength of a universal adhesive to deep dentin
author Gre, Cristina
author_facet Gre, Cristina
Amaral Caldeira de Andrada, MAuro
Monteiro Junior, Sylvio
author_role author
author2 Amaral Caldeira de Andrada, MAuro
Monteiro Junior, Sylvio
author2_role author
author
dc.contributor.author.fl_str_mv Gre, Cristina
Amaral Caldeira de Andrada, MAuro
Monteiro Junior, Sylvio
description Objective: This study evaluated the microtensile bond strength of a universal adhesive system applied to deep dentin under different bonding strategies. Material and Methods: Fifteen human third molars had the coronal portion removed exposing deep dentin and were assigned into 3 groups according to the adhesive system: G1(control): 2-steps totaletch (Adper Single Bond 2, 3M ESPE); G2: 1-step self-etch universal adhesive (Scotchbond Universal, 3M ESPE); G3:2 steps total-etch universal adhesive (Scotchbond Universal, 3M ESPE). Composite buildups were performed on the dentin surfaces and after water storage for 24 h, teeth were sectioned to obtain 40 bonded beams per group with sectional area of 0.9 mm2 . The specimens were submitted to the microtensile bond strength (µTBS) test until failure. Statistical analyses were computed using one-way ANOVA (p = 0.05). Results: The mean µTBS (in MPa) were G1 = 22.27, G2 = 22.85 and G3 = 20.3. After statistical analysis, no significant differences were observed among the groups. Conclusions: Universal adhesive system performed similarly to the total-etch adhesive and was not affected by the adhesion strategy. KEYWORDS Microtensile; Adhesive system; Dentin.
publishDate 2016
dc.date.none.fl_str_mv 2016-07-07
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://ojs.ict.unesp.br/index.php/cob/article/view/1259
10.14295/bds.2016.v19i2.1259
url https://ojs.ict.unesp.br/index.php/cob/article/view/1259
identifier_str_mv 10.14295/bds.2016.v19i2.1259
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://ojs.ict.unesp.br/index.php/cob/article/view/1259/1031
https://ojs.ict.unesp.br/index.php/cob/article/view/1259/2646
https://ojs.ict.unesp.br/index.php/cob/article/view/1259/2647
https://ojs.ict.unesp.br/index.php/cob/article/view/1259/2648
https://ojs.ict.unesp.br/index.php/cob/article/view/1259/2649
dc.rights.driver.fl_str_mv Copyright (c) 2016 Brazilian Dental Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2016 Brazilian Dental Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/vnd.openxmlformats-officedocument.wordprocessingml.document
application/vnd.openxmlformats-officedocument.wordprocessingml.document
application/vnd.openxmlformats-officedocument.wordprocessingml.document
application/vnd.openxmlformats-officedocument.wordprocessingml.document
dc.publisher.none.fl_str_mv Institute of Science and Technology of São José dos Campos
publisher.none.fl_str_mv Institute of Science and Technology of São José dos Campos
dc.source.none.fl_str_mv Brazilian Dental Science; Vol. 19 No. 2 (2016): Apr. - Jun. / 2016 - Published June 2016; 104-110
Brazilian Dental Science; v. 19 n. 2 (2016): Apr. - Jun. / 2016 - Published June 2016; 104-110
2178-6011
reponame:Brazilian Dental Science
instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Brazilian Dental Science
collection Brazilian Dental Science
repository.name.fl_str_mv Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
repository.mail.fl_str_mv sergio@fosjc.unesp.br||sergio@fosjc.unesp.br
_version_ 1788346899708772352