Flexural strength of direct composites submitted to post-polymerization heat
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Brazilian Dental Science |
Texto Completo: | https://ojs.ict.unesp.br/index.php/cob/article/view/202 |
Resumo: | The purpose of this study was to assess the effects of post-polymerization heat on the flexural strength of direct composites. Direct composite specimens (n=10), measuring 25×2×2 mm (Z-250 and P-60), were polymerized by 3 methods: (1) light-polymerized for 40 seconds, (2) (1) + post-polymerization in an oven at 120ºC for 20 minutes, and (3) (1) post-polymerization in an autoclave at 120ºC for 20 minutes. Specimens (n=10) of the indirect composite Artglass (control group) were polymerized in a UniXS oven. Specimens were stored in distilled water for 24 hours at 37ºC and then submitted to a flexural 3-point bending test with a universal testing machine. Flexural strength (MPa) data were analyzed by one-way ANOVA and Tukey´s multiple comparison test (α=.05). Results showed that (1) additional heat polymerization in an oven provided significantly (p<.05) higher flexural strengths (Z250: 158.85 MPa and P60: 147.10 MPa) than that of the Artglass resin (121.52 MPa); (2) with additional heat polymerization in an autoclave, these direct resins presented mean flexural strengths (Z250: 134.54 MPa and P60: 130.18 MPa) similar to that of Artglass (P>.05); (3) groups that were only light-polymerized (Z250: 124.75 MPa and P60: 128.96 MPa) were similar to Artglass (P>.05). When composites were only light-polymerized, they showed a flexural strength behavior similar to that of the indirect composite Artglass. The post-polymerization heat do not enhanced the resistance of the Filtek P60, but increased the strength of the Filtek Z250 when additional heat polymerization in a oven |
id |
UNESP-20_93b09d47d3f7a0aa3ca5341af5dfc2c5 |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/202 |
network_acronym_str |
UNESP-20 |
network_name_str |
Brazilian Dental Science |
repository_id_str |
|
spelling |
Flexural strength of direct composites submitted to post-polymerization heat The purpose of this study was to assess the effects of post-polymerization heat on the flexural strength of direct composites. Direct composite specimens (n=10), measuring 25×2×2 mm (Z-250 and P-60), were polymerized by 3 methods: (1) light-polymerized for 40 seconds, (2) (1) + post-polymerization in an oven at 120ºC for 20 minutes, and (3) (1) post-polymerization in an autoclave at 120ºC for 20 minutes. Specimens (n=10) of the indirect composite Artglass (control group) were polymerized in a UniXS oven. Specimens were stored in distilled water for 24 hours at 37ºC and then submitted to a flexural 3-point bending test with a universal testing machine. Flexural strength (MPa) data were analyzed by one-way ANOVA and Tukey´s multiple comparison test (α=.05). Results showed that (1) additional heat polymerization in an oven provided significantly (p<.05) higher flexural strengths (Z250: 158.85 MPa and P60: 147.10 MPa) than that of the Artglass resin (121.52 MPa); (2) with additional heat polymerization in an autoclave, these direct resins presented mean flexural strengths (Z250: 134.54 MPa and P60: 130.18 MPa) similar to that of Artglass (P>.05); (3) groups that were only light-polymerized (Z250: 124.75 MPa and P60: 128.96 MPa) were similar to Artglass (P>.05). When composites were only light-polymerized, they showed a flexural strength behavior similar to that of the indirect composite Artglass. The post-polymerization heat do not enhanced the resistance of the Filtek P60, but increased the strength of the Filtek Z250 when additional heat polymerization in a ovenInstitute of Science and Technology of São José dos Campos2010-08-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ojs.ict.unesp.br/index.php/cob/article/view/20210.14295/bds.2006.v9i3.202Brazilian Dental Science; Vol. 9 No. 3 (2006)Brazilian Dental Science; v. 9 n. 3 (2006)2178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESPporhttps://ojs.ict.unesp.br/index.php/cob/article/view/202/146Rocha, Sicknan Soares daAdabo, Gelson LuisFonseca, Renata Garciainfo:eu-repo/semantics/openAccess2018-08-30T09:12:35Zoai:ojs.pkp.sfu.ca:article/202Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2022-11-08T16:29:26.100670Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)true |
dc.title.none.fl_str_mv |
Flexural strength of direct composites submitted to post-polymerization heat |
title |
Flexural strength of direct composites submitted to post-polymerization heat |
spellingShingle |
Flexural strength of direct composites submitted to post-polymerization heat Rocha, Sicknan Soares da |
title_short |
Flexural strength of direct composites submitted to post-polymerization heat |
title_full |
Flexural strength of direct composites submitted to post-polymerization heat |
title_fullStr |
Flexural strength of direct composites submitted to post-polymerization heat |
title_full_unstemmed |
Flexural strength of direct composites submitted to post-polymerization heat |
title_sort |
Flexural strength of direct composites submitted to post-polymerization heat |
author |
Rocha, Sicknan Soares da |
author_facet |
Rocha, Sicknan Soares da Adabo, Gelson Luis Fonseca, Renata Garcia |
author_role |
author |
author2 |
Adabo, Gelson Luis Fonseca, Renata Garcia |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Rocha, Sicknan Soares da Adabo, Gelson Luis Fonseca, Renata Garcia |
description |
The purpose of this study was to assess the effects of post-polymerization heat on the flexural strength of direct composites. Direct composite specimens (n=10), measuring 25×2×2 mm (Z-250 and P-60), were polymerized by 3 methods: (1) light-polymerized for 40 seconds, (2) (1) + post-polymerization in an oven at 120ºC for 20 minutes, and (3) (1) post-polymerization in an autoclave at 120ºC for 20 minutes. Specimens (n=10) of the indirect composite Artglass (control group) were polymerized in a UniXS oven. Specimens were stored in distilled water for 24 hours at 37ºC and then submitted to a flexural 3-point bending test with a universal testing machine. Flexural strength (MPa) data were analyzed by one-way ANOVA and Tukey´s multiple comparison test (α=.05). Results showed that (1) additional heat polymerization in an oven provided significantly (p<.05) higher flexural strengths (Z250: 158.85 MPa and P60: 147.10 MPa) than that of the Artglass resin (121.52 MPa); (2) with additional heat polymerization in an autoclave, these direct resins presented mean flexural strengths (Z250: 134.54 MPa and P60: 130.18 MPa) similar to that of Artglass (P>.05); (3) groups that were only light-polymerized (Z250: 124.75 MPa and P60: 128.96 MPa) were similar to Artglass (P>.05). When composites were only light-polymerized, they showed a flexural strength behavior similar to that of the indirect composite Artglass. The post-polymerization heat do not enhanced the resistance of the Filtek P60, but increased the strength of the Filtek Z250 when additional heat polymerization in a oven |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-08-10 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/202 10.14295/bds.2006.v9i3.202 |
url |
https://ojs.ict.unesp.br/index.php/cob/article/view/202 |
identifier_str_mv |
10.14295/bds.2006.v9i3.202 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/202/146 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
dc.source.none.fl_str_mv |
Brazilian Dental Science; Vol. 9 No. 3 (2006) Brazilian Dental Science; v. 9 n. 3 (2006) 2178-6011 reponame:Brazilian Dental Science instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Brazilian Dental Science |
collection |
Brazilian Dental Science |
repository.name.fl_str_mv |
Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
repository.mail.fl_str_mv |
sergio@fosjc.unesp.br||sergio@fosjc.unesp.br |
_version_ |
1788346896395272192 |