Effect of Different Immediate Implant Loading Protocols on Peri-implant Soft Tissue Health
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Science |
Texto Completo: | https://ojs.ict.unesp.br/index.php/cob/article/view/1998 |
Resumo: | Objective:This clinical study was conducted to evaluate the effect of immediate loading on peri-implant soft tissue health using three protocols: i) Immediate functional loading using polymer infiltrated ceramic (PIC) material (IFLV). ii)Immediate functional loading using polymethyl methacrylate (PMMA) followed by delayed functional loading using PIC material (IFLP). iii) Immediate non-functional loading using PMMA followed by delayed functional loading using PIC material (INFLP). Material & Methods: 30 Implants were placed in the upper premolar area and divided randomly according to the immediate loading protocol. In the control group (INFLP), CAD/CAM PMMA crowns were placed out of occlusion for 3 months, and then replaced by CAD/CAM VITA ENAMIC crowns in functional occlusion. For (IFLV) group, CAD/CAM VITA ENAMIC crowns were immediately loaded in functional occlusion; while in (IFLP) group, CAD/CAM PMMA crowns were placed in functional occlusion for 3 months, and then replaced by CAD/CAM VITA ENAMIC crowns. Modified pink esthetic score (MPES) and probing depth were used for evaluation of peri-implant soft tissue at base line and follow up periods. Results: INFLP showed higher MPES results compared to IFLV and IFLP. Moreover, the INFLP probing depth at 3 months showed higher results compared to the other groups. Conclusions: Immediate non-functional loading showed the best outcomes. However, peri-implant soft tissue health of the immediate functional loading using the PIC crown material was clinically acceptable.Key WordsPolymer infiltrated ceramics, immediate dental implant loading, peri-implant soft tissue health. |
id |
UNESP-20_cf5bd23f832b1a2090a9413f5bd809e7 |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/1998 |
network_acronym_str |
UNESP-20 |
network_name_str |
Brazilian Dental Science |
repository_id_str |
|
spelling |
Effect of Different Immediate Implant Loading Protocols on Peri-implant Soft Tissue HealthObjective:This clinical study was conducted to evaluate the effect of immediate loading on peri-implant soft tissue health using three protocols: i) Immediate functional loading using polymer infiltrated ceramic (PIC) material (IFLV). ii)Immediate functional loading using polymethyl methacrylate (PMMA) followed by delayed functional loading using PIC material (IFLP). iii) Immediate non-functional loading using PMMA followed by delayed functional loading using PIC material (INFLP). Material & Methods: 30 Implants were placed in the upper premolar area and divided randomly according to the immediate loading protocol. In the control group (INFLP), CAD/CAM PMMA crowns were placed out of occlusion for 3 months, and then replaced by CAD/CAM VITA ENAMIC crowns in functional occlusion. For (IFLV) group, CAD/CAM VITA ENAMIC crowns were immediately loaded in functional occlusion; while in (IFLP) group, CAD/CAM PMMA crowns were placed in functional occlusion for 3 months, and then replaced by CAD/CAM VITA ENAMIC crowns. Modified pink esthetic score (MPES) and probing depth were used for evaluation of peri-implant soft tissue at base line and follow up periods. Results: INFLP showed higher MPES results compared to IFLV and IFLP. Moreover, the INFLP probing depth at 3 months showed higher results compared to the other groups. Conclusions: Immediate non-functional loading showed the best outcomes. However, peri-implant soft tissue health of the immediate functional loading using the PIC crown material was clinically acceptable.Key WordsPolymer infiltrated ceramics, immediate dental implant loading, peri-implant soft tissue health.Institute of Science and Technology of São José dos Campos2020-09-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ojs.ict.unesp.br/index.php/cob/article/view/199810.14295/bds.2020.v23i4.1998Brazilian Dental Science; Vol. 23 No. 4 (2020): Oct - Dec / 2020 - published Sep 2020; 7pBrazilian Dental Science; v. 23 n. 4 (2020): Oct - Dec / 2020 - published Sep 2020; 7p2178-6011reponame:Brazilian Dental Scienceinstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESPenghttps://ojs.ict.unesp.br/index.php/cob/article/view/1998/4157Copyright (c) 2020 Brazilian Dental Scienceinfo:eu-repo/semantics/openAccessRefaie, AshrafZohdy, MagedAboelfadl, AhmadWahsh, Marwa2020-09-30T23:03:30Zoai:ojs.pkp.sfu.ca:article/1998Revistahttp://bds.ict.unesp.br/PUBhttp://ojs.fosjc.unesp.br/index.php/index/oaisergio@fosjc.unesp.br||sergio@fosjc.unesp.br2178-60112178-6011opendoar:2022-11-08T16:30:28.884824Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)true |
dc.title.none.fl_str_mv |
Effect of Different Immediate Implant Loading Protocols on Peri-implant Soft Tissue Health |
title |
Effect of Different Immediate Implant Loading Protocols on Peri-implant Soft Tissue Health |
spellingShingle |
Effect of Different Immediate Implant Loading Protocols on Peri-implant Soft Tissue Health Refaie, Ashraf |
title_short |
Effect of Different Immediate Implant Loading Protocols on Peri-implant Soft Tissue Health |
title_full |
Effect of Different Immediate Implant Loading Protocols on Peri-implant Soft Tissue Health |
title_fullStr |
Effect of Different Immediate Implant Loading Protocols on Peri-implant Soft Tissue Health |
title_full_unstemmed |
Effect of Different Immediate Implant Loading Protocols on Peri-implant Soft Tissue Health |
title_sort |
Effect of Different Immediate Implant Loading Protocols on Peri-implant Soft Tissue Health |
author |
Refaie, Ashraf |
author_facet |
Refaie, Ashraf Zohdy, Maged Aboelfadl, Ahmad Wahsh, Marwa |
author_role |
author |
author2 |
Zohdy, Maged Aboelfadl, Ahmad Wahsh, Marwa |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Refaie, Ashraf Zohdy, Maged Aboelfadl, Ahmad Wahsh, Marwa |
description |
Objective:This clinical study was conducted to evaluate the effect of immediate loading on peri-implant soft tissue health using three protocols: i) Immediate functional loading using polymer infiltrated ceramic (PIC) material (IFLV). ii)Immediate functional loading using polymethyl methacrylate (PMMA) followed by delayed functional loading using PIC material (IFLP). iii) Immediate non-functional loading using PMMA followed by delayed functional loading using PIC material (INFLP). Material & Methods: 30 Implants were placed in the upper premolar area and divided randomly according to the immediate loading protocol. In the control group (INFLP), CAD/CAM PMMA crowns were placed out of occlusion for 3 months, and then replaced by CAD/CAM VITA ENAMIC crowns in functional occlusion. For (IFLV) group, CAD/CAM VITA ENAMIC crowns were immediately loaded in functional occlusion; while in (IFLP) group, CAD/CAM PMMA crowns were placed in functional occlusion for 3 months, and then replaced by CAD/CAM VITA ENAMIC crowns. Modified pink esthetic score (MPES) and probing depth were used for evaluation of peri-implant soft tissue at base line and follow up periods. Results: INFLP showed higher MPES results compared to IFLV and IFLP. Moreover, the INFLP probing depth at 3 months showed higher results compared to the other groups. Conclusions: Immediate non-functional loading showed the best outcomes. However, peri-implant soft tissue health of the immediate functional loading using the PIC crown material was clinically acceptable.Key WordsPolymer infiltrated ceramics, immediate dental implant loading, peri-implant soft tissue health. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-09-30 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/1998 10.14295/bds.2020.v23i4.1998 |
url |
https://ojs.ict.unesp.br/index.php/cob/article/view/1998 |
identifier_str_mv |
10.14295/bds.2020.v23i4.1998 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://ojs.ict.unesp.br/index.php/cob/article/view/1998/4157 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2020 Brazilian Dental Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2020 Brazilian Dental Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
publisher.none.fl_str_mv |
Institute of Science and Technology of São José dos Campos |
dc.source.none.fl_str_mv |
Brazilian Dental Science; Vol. 23 No. 4 (2020): Oct - Dec / 2020 - published Sep 2020; 7p Brazilian Dental Science; v. 23 n. 4 (2020): Oct - Dec / 2020 - published Sep 2020; 7p 2178-6011 reponame:Brazilian Dental Science instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Brazilian Dental Science |
collection |
Brazilian Dental Science |
repository.name.fl_str_mv |
Brazilian Dental Science - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
repository.mail.fl_str_mv |
sergio@fosjc.unesp.br||sergio@fosjc.unesp.br |
_version_ |
1788346901433679872 |