Determination of copper at wide range concentrations using instrumental features of high-resolution continuum source flame atomic absorption spectrometry
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Eclética Química |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702010000400011 |
Resumo: | This work describes a method to determine Cu at wide range concentrations in a single run without need of further dilutions employing high-resolution continuum source flame atomic absorption spectrometry. Different atomic lines for Cu at 324.754 nm, 327.396 nm, 222.570 nm, 249.215 nm and 224.426 nm were evaluated and main figures of merit established. Absorbance measurements at 324.754 nm, 249.215 nm and 224.426 nm allows the determination of Cu in the 0.07 - 5.0 mg L-1, 5.0 - 100 mg L-1 and 100 - 800 mg L-1 concentration intervals respectively with linear correlation coefficients better than 0.998. Limits of detection were 21 µg L-1, 310 µg L-1 and 1400 µg L-1 for 324.754 nm, 249.215 nm and 224.426 nm, respectively and relative standard deviations (n = 12) were £ 2.7%. The proposed method was applied to water samples spiked with Cu and the results were in agreement at a 95% of confidence level (paired t-test) with those obtained by line-source flame atomic absorption spectrometry. |
id |
UNESP-29_95989d97eb911055c8b338830877b21f |
---|---|
oai_identifier_str |
oai:scielo:S0100-46702010000400011 |
network_acronym_str |
UNESP-29 |
network_name_str |
Eclética Química |
repository_id_str |
|
spelling |
Determination of copper at wide range concentrations using instrumental features of high-resolution continuum source flame atomic absorption spectrometryCopperHR-CS FAASWide range determinationThis work describes a method to determine Cu at wide range concentrations in a single run without need of further dilutions employing high-resolution continuum source flame atomic absorption spectrometry. Different atomic lines for Cu at 324.754 nm, 327.396 nm, 222.570 nm, 249.215 nm and 224.426 nm were evaluated and main figures of merit established. Absorbance measurements at 324.754 nm, 249.215 nm and 224.426 nm allows the determination of Cu in the 0.07 - 5.0 mg L-1, 5.0 - 100 mg L-1 and 100 - 800 mg L-1 concentration intervals respectively with linear correlation coefficients better than 0.998. Limits of detection were 21 µg L-1, 310 µg L-1 and 1400 µg L-1 for 324.754 nm, 249.215 nm and 224.426 nm, respectively and relative standard deviations (n = 12) were £ 2.7%. The proposed method was applied to water samples spiked with Cu and the results were in agreement at a 95% of confidence level (paired t-test) with those obtained by line-source flame atomic absorption spectrometry.Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP2010-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702010000400011Eclética Química v.35 n.4 2010reponame:Eclética Químicainstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESP10.1590/S0100-46702010000400011info:eu-repo/semantics/openAccessLima,Renata ToledoRaposo Jr.,Jorge LuizVirgílio,AlexGomes Neto,José Anchietaeng2011-08-23T00:00:00Zoai:scielo:S0100-46702010000400011Revistahttp://revista.iq.unesp.br/ojs/index.php/ecletica/PUBhttps://revista.iq.unesp.br/ojs/index.php/ecletica/oaiecletica@ctrlk.com.br||ecletica@iq.unesp.br1678-46181678-4618opendoar:2011-08-23T00:00Eclética Química - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)false |
dc.title.none.fl_str_mv |
Determination of copper at wide range concentrations using instrumental features of high-resolution continuum source flame atomic absorption spectrometry |
title |
Determination of copper at wide range concentrations using instrumental features of high-resolution continuum source flame atomic absorption spectrometry |
spellingShingle |
Determination of copper at wide range concentrations using instrumental features of high-resolution continuum source flame atomic absorption spectrometry Lima,Renata Toledo Copper HR-CS FAAS Wide range determination |
title_short |
Determination of copper at wide range concentrations using instrumental features of high-resolution continuum source flame atomic absorption spectrometry |
title_full |
Determination of copper at wide range concentrations using instrumental features of high-resolution continuum source flame atomic absorption spectrometry |
title_fullStr |
Determination of copper at wide range concentrations using instrumental features of high-resolution continuum source flame atomic absorption spectrometry |
title_full_unstemmed |
Determination of copper at wide range concentrations using instrumental features of high-resolution continuum source flame atomic absorption spectrometry |
title_sort |
Determination of copper at wide range concentrations using instrumental features of high-resolution continuum source flame atomic absorption spectrometry |
author |
Lima,Renata Toledo |
author_facet |
Lima,Renata Toledo Raposo Jr.,Jorge Luiz Virgílio,Alex Gomes Neto,José Anchieta |
author_role |
author |
author2 |
Raposo Jr.,Jorge Luiz Virgílio,Alex Gomes Neto,José Anchieta |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Lima,Renata Toledo Raposo Jr.,Jorge Luiz Virgílio,Alex Gomes Neto,José Anchieta |
dc.subject.por.fl_str_mv |
Copper HR-CS FAAS Wide range determination |
topic |
Copper HR-CS FAAS Wide range determination |
description |
This work describes a method to determine Cu at wide range concentrations in a single run without need of further dilutions employing high-resolution continuum source flame atomic absorption spectrometry. Different atomic lines for Cu at 324.754 nm, 327.396 nm, 222.570 nm, 249.215 nm and 224.426 nm were evaluated and main figures of merit established. Absorbance measurements at 324.754 nm, 249.215 nm and 224.426 nm allows the determination of Cu in the 0.07 - 5.0 mg L-1, 5.0 - 100 mg L-1 and 100 - 800 mg L-1 concentration intervals respectively with linear correlation coefficients better than 0.998. Limits of detection were 21 µg L-1, 310 µg L-1 and 1400 µg L-1 for 324.754 nm, 249.215 nm and 224.426 nm, respectively and relative standard deviations (n = 12) were £ 2.7%. The proposed method was applied to water samples spiked with Cu and the results were in agreement at a 95% of confidence level (paired t-test) with those obtained by line-source flame atomic absorption spectrometry. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702010000400011 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702010000400011 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0100-46702010000400011 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP |
publisher.none.fl_str_mv |
Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP |
dc.source.none.fl_str_mv |
Eclética Química v.35 n.4 2010 reponame:Eclética Química instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Eclética Química |
collection |
Eclética Química |
repository.name.fl_str_mv |
Eclética Química - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP) |
repository.mail.fl_str_mv |
ecletica@ctrlk.com.br||ecletica@iq.unesp.br |
_version_ |
1754734618751270912 |