Amperometric biosensor for ascorbic acid

Detalhes bibliográficos
Autor(a) principal: Tomita,I. N.
Data de Publicação: 2005
Outros Autores: Manzoli,A., Fertonani,F. L., Yamanaka,H.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Eclética Química
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702005000200005
Resumo: A L-ascorbic acid biosensor based on ascorbate oxidase has been developed. The enzyme was extracted from the mesocarp of cucumber (Cucumis sativus) by using 0.05 mol L-1 phosphate buffer, pH 5.8 containing 0.5 mol L-1 NaCl. After the dialysis versus phosphate buffer 0.05 mol L-1 pH 5.8, the enzyme was immobilized onto nylon net through glutaraldehyde covalent bond. The membrane was coupled to an O2 electrode and the yielding reaction monitored by oxygen depletion at -600 mV using flow injection analysis optimized to 0.1 mol L-1 phosphate buffer pH 5.8, as the carrier solution and flow-rate of 0.5 mL min-1. The ascorbic acid calibration curve was linear from 1.2x10-4 to 1.0x10-3 mol L-1. The evaluation of biosensor lifetime leads to 500 injections. Commercial pharmaceutical samples were analyzed with the proposed method and the results were compared with those obtained by high-performance liquid chromatography (HPLC).
id UNESP-29_99b523a23de91ae3359645b5e543833d
oai_identifier_str oai:scielo:S0100-46702005000200005
network_acronym_str UNESP-29
network_name_str Eclética Química
repository_id_str
spelling Amperometric biosensor for ascorbic acidbiosensorascorbic acidflow injection analysisA L-ascorbic acid biosensor based on ascorbate oxidase has been developed. The enzyme was extracted from the mesocarp of cucumber (Cucumis sativus) by using 0.05 mol L-1 phosphate buffer, pH 5.8 containing 0.5 mol L-1 NaCl. After the dialysis versus phosphate buffer 0.05 mol L-1 pH 5.8, the enzyme was immobilized onto nylon net through glutaraldehyde covalent bond. The membrane was coupled to an O2 electrode and the yielding reaction monitored by oxygen depletion at -600 mV using flow injection analysis optimized to 0.1 mol L-1 phosphate buffer pH 5.8, as the carrier solution and flow-rate of 0.5 mL min-1. The ascorbic acid calibration curve was linear from 1.2x10-4 to 1.0x10-3 mol L-1. The evaluation of biosensor lifetime leads to 500 injections. Commercial pharmaceutical samples were analyzed with the proposed method and the results were compared with those obtained by high-performance liquid chromatography (HPLC).Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP2005-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702005000200005Eclética Química v.30 n.2 2005reponame:Eclética Químicainstname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)instacron:UNESP10.1590/S0100-46702005000200005info:eu-repo/semantics/openAccessTomita,I. N.Manzoli,A.Fertonani,F. L.Yamanaka,H.eng2005-09-05T00:00:00Zoai:scielo:S0100-46702005000200005Revistahttp://revista.iq.unesp.br/ojs/index.php/ecletica/PUBhttps://revista.iq.unesp.br/ojs/index.php/ecletica/oaiecletica@ctrlk.com.br||ecletica@iq.unesp.br1678-46181678-4618opendoar:2005-09-05T00:00Eclética Química - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)false
dc.title.none.fl_str_mv Amperometric biosensor for ascorbic acid
title Amperometric biosensor for ascorbic acid
spellingShingle Amperometric biosensor for ascorbic acid
Tomita,I. N.
biosensor
ascorbic acid
flow injection analysis
title_short Amperometric biosensor for ascorbic acid
title_full Amperometric biosensor for ascorbic acid
title_fullStr Amperometric biosensor for ascorbic acid
title_full_unstemmed Amperometric biosensor for ascorbic acid
title_sort Amperometric biosensor for ascorbic acid
author Tomita,I. N.
author_facet Tomita,I. N.
Manzoli,A.
Fertonani,F. L.
Yamanaka,H.
author_role author
author2 Manzoli,A.
Fertonani,F. L.
Yamanaka,H.
author2_role author
author
author
dc.contributor.author.fl_str_mv Tomita,I. N.
Manzoli,A.
Fertonani,F. L.
Yamanaka,H.
dc.subject.por.fl_str_mv biosensor
ascorbic acid
flow injection analysis
topic biosensor
ascorbic acid
flow injection analysis
description A L-ascorbic acid biosensor based on ascorbate oxidase has been developed. The enzyme was extracted from the mesocarp of cucumber (Cucumis sativus) by using 0.05 mol L-1 phosphate buffer, pH 5.8 containing 0.5 mol L-1 NaCl. After the dialysis versus phosphate buffer 0.05 mol L-1 pH 5.8, the enzyme was immobilized onto nylon net through glutaraldehyde covalent bond. The membrane was coupled to an O2 electrode and the yielding reaction monitored by oxygen depletion at -600 mV using flow injection analysis optimized to 0.1 mol L-1 phosphate buffer pH 5.8, as the carrier solution and flow-rate of 0.5 mL min-1. The ascorbic acid calibration curve was linear from 1.2x10-4 to 1.0x10-3 mol L-1. The evaluation of biosensor lifetime leads to 500 injections. Commercial pharmaceutical samples were analyzed with the proposed method and the results were compared with those obtained by high-performance liquid chromatography (HPLC).
publishDate 2005
dc.date.none.fl_str_mv 2005-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702005000200005
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-46702005000200005
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0100-46702005000200005
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP
publisher.none.fl_str_mv Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP
dc.source.none.fl_str_mv Eclética Química v.30 n.2 2005
reponame:Eclética Química
instname:Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Eclética Química
collection Eclética Química
repository.name.fl_str_mv Eclética Química - Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)
repository.mail.fl_str_mv ecletica@ctrlk.com.br||ecletica@iq.unesp.br
_version_ 1754734617702694912