Study of the thermal performance of buried and semi-buried test cells
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | PARC (Campinas) |
Texto Completo: | https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8653908 |
Resumo: | A vernacular housing alternative widely used by indigenous groups in southern Brazil is based on burying the more significant part of the dwellings and covering it with a vegetated roof. The present study aims to verify the thermal performance of buried and semi-buried test cells when compared to a ground control cell as a bioclimatic strategy. The method is based on the comparison of temperature variations measured inside test cells concerning external and soil temperature measured in Curitiba, PR, during the winter period. The test cells were made on a reduced scale, all with the same dimensions and material specifications. The performance of each test cell was evaluated through the analysis of thermal fluctuations, time lag, differences in temperature, and amplitudes of surface sensors and comfort levels. Data analysis revealed that the buried test cell presented lower thermal amplitude and longer time lag. Regarding the sum of degrees-hours outside the comfort temperature range, the buried test cell obtained the best performance during the winter period. It was also possible to verify that a greater surface area in contact with the soil increases the thermal performance. |
id |
UNICAMP-20_59ca52f154d11dc80d05528a1029c9b0 |
---|---|
oai_identifier_str |
oai:ojs.periodicos.sbu.unicamp.br:article/8653908 |
network_acronym_str |
UNICAMP-20 |
network_name_str |
PARC (Campinas) |
repository_id_str |
|
spelling |
Study of the thermal performance of buried and semi-buried test cellsEstudo do desempenho térmico de células-teste enterrada e semienterradaThermal inertiaUnderground constructionBuried construction.Inércia térmica.Construção subterrâneaConstrução enterrada.A vernacular housing alternative widely used by indigenous groups in southern Brazil is based on burying the more significant part of the dwellings and covering it with a vegetated roof. The present study aims to verify the thermal performance of buried and semi-buried test cells when compared to a ground control cell as a bioclimatic strategy. The method is based on the comparison of temperature variations measured inside test cells concerning external and soil temperature measured in Curitiba, PR, during the winter period. The test cells were made on a reduced scale, all with the same dimensions and material specifications. The performance of each test cell was evaluated through the analysis of thermal fluctuations, time lag, differences in temperature, and amplitudes of surface sensors and comfort levels. Data analysis revealed that the buried test cell presented lower thermal amplitude and longer time lag. Regarding the sum of degrees-hours outside the comfort temperature range, the buried test cell obtained the best performance during the winter period. It was also possible to verify that a greater surface area in contact with the soil increases the thermal performance.Uma alternativa construtiva vernacular dos grupos indígenas na região sul do Brasil baseava-se no enterramento da edificação com o provimento de cobertura leve. O presente estudo tem por objetivo avaliar o desempenho térmico de células-teste enterradas e semienterradas quando comparadas a uma célula controle térrea visando uma arquitetura bioclimática que utilize métodos passivos. O método é baseado na comparação das variações de temperatura medida no interior de células-teste quanto à temperatura externa e do solo medidos em Curitiba, PR, durante o período de inverno. As células testes foram confeccionadas em escala reduzida, todas com as mesmas dimensões e especificações de materiais. Para a avaliação de desempenho foram analisados a amplitude térmica, o atraso térmico, as diferenças de temperaturas e amplitudes de sensores superficiais e os índices de conforto de cada célula-teste. A análise de dados constatou que a célula-teste enterrada apresentou menor amplitude térmica e maior atraso térmico. No que tange à somatória dos graus-hora fora da faixa de temperatura de conforto, a célula-teste enterrada obteve o menor tempo em desconforto durante o período de inverno. Foi possível verificar também que quanto maior a área em contato com o solo, melhores as condições de conforto observadas.Universidade Estadual de Campinas2019-05-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionQuasi-experimental researchPesquisa quase-experimentalapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/865390810.20396/parc.v10i0.8653908PARC Pesquisa em Arquitetura e Construção; Vol. 10 (2019): Continuous publication; e019023PARC Pesquisa em Arquitetura e Construção; Vol. 10 (2019): Publicação contínua; e019023PARC Pesquisa em Arquitetura e Construção; v. 10 (2019): Publicação contínua; e0190231980-6809reponame:PARC (Campinas)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPporhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8653908/20832Brazil; 2019Brasil; 2019Copyright (c) 2019 PARC Pesquisa em Arquitetura e Construçãoinfo:eu-repo/semantics/openAccessBiasi, Juliana AparecidaKrüger, Eduardo Leite2020-03-13T17:53:51Zoai:ojs.periodicos.sbu.unicamp.br:article/8653908Revistahttp://periodicos.sbu.unicamp.br/ojs/index.php/parcPUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/oai||parc@fec.unicamp.br1980-68091980-6809opendoar:2020-03-13T17:53:51PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP)false |
dc.title.none.fl_str_mv |
Study of the thermal performance of buried and semi-buried test cells Estudo do desempenho térmico de células-teste enterrada e semienterrada |
title |
Study of the thermal performance of buried and semi-buried test cells |
spellingShingle |
Study of the thermal performance of buried and semi-buried test cells Biasi, Juliana Aparecida Thermal inertia Underground construction Buried construction. Inércia térmica. Construção subterrânea Construção enterrada. |
title_short |
Study of the thermal performance of buried and semi-buried test cells |
title_full |
Study of the thermal performance of buried and semi-buried test cells |
title_fullStr |
Study of the thermal performance of buried and semi-buried test cells |
title_full_unstemmed |
Study of the thermal performance of buried and semi-buried test cells |
title_sort |
Study of the thermal performance of buried and semi-buried test cells |
author |
Biasi, Juliana Aparecida |
author_facet |
Biasi, Juliana Aparecida Krüger, Eduardo Leite |
author_role |
author |
author2 |
Krüger, Eduardo Leite |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Biasi, Juliana Aparecida Krüger, Eduardo Leite |
dc.subject.por.fl_str_mv |
Thermal inertia Underground construction Buried construction. Inércia térmica. Construção subterrânea Construção enterrada. |
topic |
Thermal inertia Underground construction Buried construction. Inércia térmica. Construção subterrânea Construção enterrada. |
description |
A vernacular housing alternative widely used by indigenous groups in southern Brazil is based on burying the more significant part of the dwellings and covering it with a vegetated roof. The present study aims to verify the thermal performance of buried and semi-buried test cells when compared to a ground control cell as a bioclimatic strategy. The method is based on the comparison of temperature variations measured inside test cells concerning external and soil temperature measured in Curitiba, PR, during the winter period. The test cells were made on a reduced scale, all with the same dimensions and material specifications. The performance of each test cell was evaluated through the analysis of thermal fluctuations, time lag, differences in temperature, and amplitudes of surface sensors and comfort levels. Data analysis revealed that the buried test cell presented lower thermal amplitude and longer time lag. Regarding the sum of degrees-hours outside the comfort temperature range, the buried test cell obtained the best performance during the winter period. It was also possible to verify that a greater surface area in contact with the soil increases the thermal performance. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-05-30 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Quasi-experimental research Pesquisa quase-experimental |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8653908 10.20396/parc.v10i0.8653908 |
url |
https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8653908 |
identifier_str_mv |
10.20396/parc.v10i0.8653908 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8653908/20832 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2019 PARC Pesquisa em Arquitetura e Construção info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2019 PARC Pesquisa em Arquitetura e Construção |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.coverage.none.fl_str_mv |
Brazil; 2019 Brasil; 2019 |
dc.publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
dc.source.none.fl_str_mv |
PARC Pesquisa em Arquitetura e Construção; Vol. 10 (2019): Continuous publication; e019023 PARC Pesquisa em Arquitetura e Construção; Vol. 10 (2019): Publicação contínua; e019023 PARC Pesquisa em Arquitetura e Construção; v. 10 (2019): Publicação contínua; e019023 1980-6809 reponame:PARC (Campinas) instname:Universidade Estadual de Campinas (UNICAMP) instacron:UNICAMP |
instname_str |
Universidade Estadual de Campinas (UNICAMP) |
instacron_str |
UNICAMP |
institution |
UNICAMP |
reponame_str |
PARC (Campinas) |
collection |
PARC (Campinas) |
repository.name.fl_str_mv |
PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP) |
repository.mail.fl_str_mv |
||parc@fec.unicamp.br |
_version_ |
1809283615006130176 |