Analysis of the thermal performance of social housing with concrete walls in Uberlândia-MG

Detalhes bibliográficos
Autor(a) principal: Oliveira, Roberta Bastos de
Data de Publicação: 2021
Outros Autores: Alves, Camila dos Reis
Tipo de documento: Artigo
Idioma: por
Título da fonte: PARC (Campinas)
Texto Completo: https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8661094
Resumo: The concrete wall construction system has been widely used in the construction of social housing (HIS). However, issues related to the thermal performance of this system need further study and attention. In this context, there is the evaluation of thermal performance according to ABNT NBR 15575: 2013 of a HIS built with concrete walls molded in loco in Uberlândia-MG. Initially, the simplified method for the real project was used to determine the level of thermal performance. Then, six scenarios were simulated for summer and winter, according to the most critical solar orientation. For the analyzes, the Energy Plus software was used for 8760 hours of the year. It is a comparison between the results obtained and the normative requirements that provide for the comparison of internal and external temperatures and internal temperatures with the temperatures of the typical day. As a result, HIS did not achieve the minimum levels for the simplified method. For the simulations, several comparatives analyze the increase or reduction of internal temperatures in the building's thermal zones. The real project with eaves and external painting in light color reached the minimum thermal performance level for summer and winter; however, other analyzes were incorporated, allowing important considerations. Criticism is also made on normative criteria for inconsistent thermal performance and the quality of design replicated in the city without concern for the user.
id UNICAMP-20_7b53911fbb4d7c8c17c3adc983230ca9
oai_identifier_str oai:ojs.periodicos.sbu.unicamp.br:article/8661094
network_acronym_str UNICAMP-20
network_name_str PARC (Campinas)
repository_id_str
spelling Analysis of the thermal performance of social housing with concrete walls in Uberlândia-MGAnálise do desempenho térmico de habitação de interesse social com paredes de concreto em Uberlândia-MGDesempenho térmicoParedes de concreto moldadas in locoHabitação de interesse socialThermal performanceConcrete walls molded in locoSocial housingThe concrete wall construction system has been widely used in the construction of social housing (HIS). However, issues related to the thermal performance of this system need further study and attention. In this context, there is the evaluation of thermal performance according to ABNT NBR 15575: 2013 of a HIS built with concrete walls molded in loco in Uberlândia-MG. Initially, the simplified method for the real project was used to determine the level of thermal performance. Then, six scenarios were simulated for summer and winter, according to the most critical solar orientation. For the analyzes, the Energy Plus software was used for 8760 hours of the year. It is a comparison between the results obtained and the normative requirements that provide for the comparison of internal and external temperatures and internal temperatures with the temperatures of the typical day. As a result, HIS did not achieve the minimum levels for the simplified method. For the simulations, several comparatives analyze the increase or reduction of internal temperatures in the building's thermal zones. The real project with eaves and external painting in light color reached the minimum thermal performance level for summer and winter; however, other analyzes were incorporated, allowing important considerations. Criticism is also made on normative criteria for inconsistent thermal performance and the quality of design replicated in the city without concern for the user.O sistema construtivo de paredes de concreto tem sido amplamente utilizado na construção de habitações de interesse social (HIS). No entanto, questões relacionadas ao desempenho térmico necessitam de maiores estudos e atenção. Neste contexto, tem-se a avaliação do desempenho térmico segundo a ABNT NBR 15575:2013 de uma HIS construída com paredes de concreto moldado in loco na cidade de Uberlândia-MG. Inicialmente foi utilizado o método simplificado para avaliação do projeto real para a determinação do nível de desempenho térmico. Em seguida, foram simulados 6 cenários para o verão e para o inverno, de acordo com a orientação solar mais crítica. Para as análises, utilizou-se o software Energy Plus com as 8760 horas do ano. Trata-se de uma comparação entre os resultados obtidos e os requisitos normativos que preveem a comparação das temperaturas internas com as externas, bem como as internas com as temperaturas do dia típico. Como resultados, a HIS não atingiu os níveis mínimos para o método simplificado. Para as simulações, tem-se diversas análises comparativas quanto ao aumento ou redução das temperaturas internas nas zonas térmicas da edificação. O projeto real com beiral e paredes externas na cor clara atingiu o nível de desempenho térmico mínimo para o verão e para o inverno, no entanto, outras análises foram incorporadas possibilitando ponderações importantes. Faz-se uma crítica também quanto aos critérios normativos para desempenho térmico que destoaram entre si e à qualidade dos projetos que têm sido replicados na cidade sem uma preocupação com o usuário.Universidade Estadual de Campinas2021-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTextoinfo:eu-repo/semantics/otherapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/866109410.20396/parc.v12i00.8661094PARC Pesquisa em Arquitetura e Construção; Vol. 12 (2021): Continous publication; e021006PARC Pesquisa em Arquitetura e Construção; Vol. 12 (2021): Publicação contínua; e021006PARC Pesquisa em Arquitetura e Construção; v. 12 (2021): Publicação contínua; e0210061980-6809reponame:PARC (Campinas)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPporhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8661094/25867Brazil; ContemporaryBrasil; ContemporâneoCopyright (c) 2021 PARC Pesquisa em Arquitetura e Construçãohttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessOliveira, Roberta Bastos deAlves, Camila dos Reis2021-10-30T18:23:33Zoai:ojs.periodicos.sbu.unicamp.br:article/8661094Revistahttp://periodicos.sbu.unicamp.br/ojs/index.php/parcPUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/oai||parc@fec.unicamp.br1980-68091980-6809opendoar:2022-11-08T14:24:48.327331PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Analysis of the thermal performance of social housing with concrete walls in Uberlândia-MG
Análise do desempenho térmico de habitação de interesse social com paredes de concreto em Uberlândia-MG
title Analysis of the thermal performance of social housing with concrete walls in Uberlândia-MG
spellingShingle Analysis of the thermal performance of social housing with concrete walls in Uberlândia-MG
Oliveira, Roberta Bastos de
Desempenho térmico
Paredes de concreto moldadas in loco
Habitação de interesse social
Thermal performance
Concrete walls molded in loco
Social housing
title_short Analysis of the thermal performance of social housing with concrete walls in Uberlândia-MG
title_full Analysis of the thermal performance of social housing with concrete walls in Uberlândia-MG
title_fullStr Analysis of the thermal performance of social housing with concrete walls in Uberlândia-MG
title_full_unstemmed Analysis of the thermal performance of social housing with concrete walls in Uberlândia-MG
title_sort Analysis of the thermal performance of social housing with concrete walls in Uberlândia-MG
author Oliveira, Roberta Bastos de
author_facet Oliveira, Roberta Bastos de
Alves, Camila dos Reis
author_role author
author2 Alves, Camila dos Reis
author2_role author
dc.contributor.author.fl_str_mv Oliveira, Roberta Bastos de
Alves, Camila dos Reis
dc.subject.por.fl_str_mv Desempenho térmico
Paredes de concreto moldadas in loco
Habitação de interesse social
Thermal performance
Concrete walls molded in loco
Social housing
topic Desempenho térmico
Paredes de concreto moldadas in loco
Habitação de interesse social
Thermal performance
Concrete walls molded in loco
Social housing
description The concrete wall construction system has been widely used in the construction of social housing (HIS). However, issues related to the thermal performance of this system need further study and attention. In this context, there is the evaluation of thermal performance according to ABNT NBR 15575: 2013 of a HIS built with concrete walls molded in loco in Uberlândia-MG. Initially, the simplified method for the real project was used to determine the level of thermal performance. Then, six scenarios were simulated for summer and winter, according to the most critical solar orientation. For the analyzes, the Energy Plus software was used for 8760 hours of the year. It is a comparison between the results obtained and the normative requirements that provide for the comparison of internal and external temperatures and internal temperatures with the temperatures of the typical day. As a result, HIS did not achieve the minimum levels for the simplified method. For the simulations, several comparatives analyze the increase or reduction of internal temperatures in the building's thermal zones. The real project with eaves and external painting in light color reached the minimum thermal performance level for summer and winter; however, other analyzes were incorporated, allowing important considerations. Criticism is also made on normative criteria for inconsistent thermal performance and the quality of design replicated in the city without concern for the user.
publishDate 2021
dc.date.none.fl_str_mv 2021-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Texto
info:eu-repo/semantics/other
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8661094
10.20396/parc.v12i00.8661094
url https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8661094
identifier_str_mv 10.20396/parc.v12i00.8661094
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8661094/25867
dc.rights.driver.fl_str_mv Copyright (c) 2021 PARC Pesquisa em Arquitetura e Construção
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2021 PARC Pesquisa em Arquitetura e Construção
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv Brazil; Contemporary
Brasil; Contemporâneo
dc.publisher.none.fl_str_mv Universidade Estadual de Campinas
publisher.none.fl_str_mv Universidade Estadual de Campinas
dc.source.none.fl_str_mv PARC Pesquisa em Arquitetura e Construção; Vol. 12 (2021): Continous publication; e021006
PARC Pesquisa em Arquitetura e Construção; Vol. 12 (2021): Publicação contínua; e021006
PARC Pesquisa em Arquitetura e Construção; v. 12 (2021): Publicação contínua; e021006
1980-6809
reponame:PARC (Campinas)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str PARC (Campinas)
collection PARC (Campinas)
repository.name.fl_str_mv PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv ||parc@fec.unicamp.br
_version_ 1800216628255784960