Application of factorial experiment as a method for the definition of bioclimatic zones from thermal comfort

Detalhes bibliográficos
Autor(a) principal: Ferreira, Camila Carvalho
Data de Publicação: 2023
Outros Autores: Carlo, Joyce Correna
Tipo de documento: Artigo
Idioma: por
Título da fonte: PARC (Campinas)
Texto Completo: https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8669076
Resumo: Bioclimatic zoning is an important tool to provide subsidies for structuring thermal performance regulations and energy efficiency codes of buildings. However, a consistent methodology for developing zoning proposals still needs to be discussed. This article aims to evaluate the applicability of the factorial design as a method for the characterization of bioclimatic zones. For this, the factorial experiment was used to analyze the variables of influence on the thermal performance of residential buildings naturally ventilated in different Brazilian climates. Thermal performance simulations were performed from the factorial, and the cities analyzed were grouped according to the performance regarding thermal comfort and influence variables. In general, the main variables of influence the thermal comfort of the buildings are the solar absorbance of the wrap, the thermal transmittance of the roofs and the ventilation. For milder climates, the thermal transmittance of the walls also had an influence, while the thermal capacity of the walls influenced the transition climates. Among the sampled localities, it is possible to recognize four patterns of behavior regarding thermal comfort and the variables of influence, enabling the grouping of cities. Four bioclimatic zones were identified and subdivided according to local ventilation needs. The originality of this work is in the proposal of characterization of bioclimatic zones based on an adaptive comfort model. More than one model of multifamily buildings was considered in a factorial analysis.
id UNICAMP-20_bc999af85e3dfbfa1f3fbfb9f07a3b56
oai_identifier_str oai:ojs.periodicos.sbu.unicamp.br:article/8669076
network_acronym_str UNICAMP-20
network_name_str PARC (Campinas)
repository_id_str
spelling Application of factorial experiment as a method for the definition of bioclimatic zones from thermal comfortAplicação de experimento fatorial como método para a definição de zonas bioclimáticas a partir do conforto térmicoBioclimatic zoningThermal perfomanceAdaptive comfortResidential buildingsZoneamento bioclimático brasileiroDesempenho térmicoConforto adaptativoEdifícios residenciaisBioclimatic zoning is an important tool to provide subsidies for structuring thermal performance regulations and energy efficiency codes of buildings. However, a consistent methodology for developing zoning proposals still needs to be discussed. This article aims to evaluate the applicability of the factorial design as a method for the characterization of bioclimatic zones. For this, the factorial experiment was used to analyze the variables of influence on the thermal performance of residential buildings naturally ventilated in different Brazilian climates. Thermal performance simulations were performed from the factorial, and the cities analyzed were grouped according to the performance regarding thermal comfort and influence variables. In general, the main variables of influence the thermal comfort of the buildings are the solar absorbance of the wrap, the thermal transmittance of the roofs and the ventilation. For milder climates, the thermal transmittance of the walls also had an influence, while the thermal capacity of the walls influenced the transition climates. Among the sampled localities, it is possible to recognize four patterns of behavior regarding thermal comfort and the variables of influence, enabling the grouping of cities. Four bioclimatic zones were identified and subdivided according to local ventilation needs. The originality of this work is in the proposal of characterization of bioclimatic zones based on an adaptive comfort model. More than one model of multifamily buildings was considered in a factorial analysis.O zoneamento bioclimático apresenta-se como importante ferramenta para fornecer subsídios para a estruturação de normativa de desempenho térmico e de códigos de eficiência energética de edificações. No entanto, uma metodologia consistente para o desenvolvimento de propostas de zoneamentos é ainda tema de ampla discussão. O objetivo deste artigo é avaliar a aplicabilidade do experimento fatorial como método para caracterização de zonas bioclimáticas. Para tal, empregou-se o experimento fatorial para a análise das variáveis de influência no desempenho térmico de edificações residenciais ventiladas naturalmente em diferentes climas brasileiros. Foram realizadas simulações de desempenho térmico a partir da fatorial e as cidades analisadas foram agrupadas de acordo com a performance quanto ao conforto térmico e com as variáveis de influência. De forma geral, as principais variáveis de influência no conforto térmico das edificações foram a absortância solar da envoltória, a transmitância térmica das coberturas e a ventilação. Para climas mais amenos a transmitância térmica das paredes também apresentou influência, enquanto a capacidade térmica das paredes apresentou influência para os climas de transição. Dentre as localidades amostradas, pode-se reconhecer quatro padrões de comportamento quanto ao conforto térmico e quanto às variáveis de influência, possibilitando o agrupamento das cidades. Identificou-se quatro zonas bioclimáticas, subdivididas de acordo com as necessidades de ventilação específicas locais. A originalidade deste trabalho está na proposta de uma caracterização de zonas bioclimáticas fundamentada em um modelo de conforto adaptativo, na inclusão de mais de um modelo de edificações multifamiliares na análise e na utilização do experimento fatorial.Universidade Estadual de Campinas2023-01-28info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTextoinfo:eu-repo/semantics/otherapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/866907610.20396/parc.v14i00.8669076PARC Pesquisa em Arquitetura e Construção; Vol. 14 (2023): Continuous publication; e023005PARC Pesquisa em Arquitetura e Construção; Vol. 14 (2023): Publicação contínua; e023005PARC Pesquisa em Arquitetura e Construção; v. 14 (2023): Publicação contínua; e0230051980-6809reponame:PARC (Campinas)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPporhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8669076/30994Brazil; ContemporaryBrasil; ContemporâneoCopyright (c) 2023 PARC Pesquisa em Arquitetura e Construçãohttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessFerreira, Camila Carvalho Carlo, Joyce Correna 2023-12-29T21:22:09Zoai:ojs.periodicos.sbu.unicamp.br:article/8669076Revistahttp://periodicos.sbu.unicamp.br/ojs/index.php/parcPUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/oai||parc@fec.unicamp.br1980-68091980-6809opendoar:2023-12-29T21:22:09PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Application of factorial experiment as a method for the definition of bioclimatic zones from thermal comfort
Aplicação de experimento fatorial como método para a definição de zonas bioclimáticas a partir do conforto térmico
title Application of factorial experiment as a method for the definition of bioclimatic zones from thermal comfort
spellingShingle Application of factorial experiment as a method for the definition of bioclimatic zones from thermal comfort
Ferreira, Camila Carvalho
Bioclimatic zoning
Thermal perfomance
Adaptive comfort
Residential buildings
Zoneamento bioclimático brasileiro
Desempenho térmico
Conforto adaptativo
Edifícios residenciais
title_short Application of factorial experiment as a method for the definition of bioclimatic zones from thermal comfort
title_full Application of factorial experiment as a method for the definition of bioclimatic zones from thermal comfort
title_fullStr Application of factorial experiment as a method for the definition of bioclimatic zones from thermal comfort
title_full_unstemmed Application of factorial experiment as a method for the definition of bioclimatic zones from thermal comfort
title_sort Application of factorial experiment as a method for the definition of bioclimatic zones from thermal comfort
author Ferreira, Camila Carvalho
author_facet Ferreira, Camila Carvalho
Carlo, Joyce Correna
author_role author
author2 Carlo, Joyce Correna
author2_role author
dc.contributor.author.fl_str_mv Ferreira, Camila Carvalho
Carlo, Joyce Correna
dc.subject.por.fl_str_mv Bioclimatic zoning
Thermal perfomance
Adaptive comfort
Residential buildings
Zoneamento bioclimático brasileiro
Desempenho térmico
Conforto adaptativo
Edifícios residenciais
topic Bioclimatic zoning
Thermal perfomance
Adaptive comfort
Residential buildings
Zoneamento bioclimático brasileiro
Desempenho térmico
Conforto adaptativo
Edifícios residenciais
description Bioclimatic zoning is an important tool to provide subsidies for structuring thermal performance regulations and energy efficiency codes of buildings. However, a consistent methodology for developing zoning proposals still needs to be discussed. This article aims to evaluate the applicability of the factorial design as a method for the characterization of bioclimatic zones. For this, the factorial experiment was used to analyze the variables of influence on the thermal performance of residential buildings naturally ventilated in different Brazilian climates. Thermal performance simulations were performed from the factorial, and the cities analyzed were grouped according to the performance regarding thermal comfort and influence variables. In general, the main variables of influence the thermal comfort of the buildings are the solar absorbance of the wrap, the thermal transmittance of the roofs and the ventilation. For milder climates, the thermal transmittance of the walls also had an influence, while the thermal capacity of the walls influenced the transition climates. Among the sampled localities, it is possible to recognize four patterns of behavior regarding thermal comfort and the variables of influence, enabling the grouping of cities. Four bioclimatic zones were identified and subdivided according to local ventilation needs. The originality of this work is in the proposal of characterization of bioclimatic zones based on an adaptive comfort model. More than one model of multifamily buildings was considered in a factorial analysis.
publishDate 2023
dc.date.none.fl_str_mv 2023-01-28
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Texto
info:eu-repo/semantics/other
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8669076
10.20396/parc.v14i00.8669076
url https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8669076
identifier_str_mv 10.20396/parc.v14i00.8669076
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8669076/30994
dc.rights.driver.fl_str_mv Copyright (c) 2023 PARC Pesquisa em Arquitetura e Construção
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2023 PARC Pesquisa em Arquitetura e Construção
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv Brazil; Contemporary
Brasil; Contemporâneo
dc.publisher.none.fl_str_mv Universidade Estadual de Campinas
publisher.none.fl_str_mv Universidade Estadual de Campinas
dc.source.none.fl_str_mv PARC Pesquisa em Arquitetura e Construção; Vol. 14 (2023): Continuous publication; e023005
PARC Pesquisa em Arquitetura e Construção; Vol. 14 (2023): Publicação contínua; e023005
PARC Pesquisa em Arquitetura e Construção; v. 14 (2023): Publicação contínua; e023005
1980-6809
reponame:PARC (Campinas)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str PARC (Campinas)
collection PARC (Campinas)
repository.name.fl_str_mv PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv ||parc@fec.unicamp.br
_version_ 1809283615734890496