Thermal performance of FAU Maranhao building in two historic moments

Detalhes bibliográficos
Autor(a) principal: Neves, Letícia de Oliveira
Data de Publicação: 2016
Outros Autores: Machado, Rodrigo Dias, Cavalcante, Rodrigo
Tipo de documento: Artigo
Idioma: por
Título da fonte: PARC (Campinas)
Texto Completo: https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8646323
Resumo: The FAU Maranhao building, beyond being an important architectural heritage of Sao Paulo city, is recognized for providing good environmental quality to its occupants. Since the building has already housed distinct uses, this paper presents studies that point out the thermal response of the building to the climate in which it is located, in two historical moments: right after its construction, which had a residential use, and nowadays, which has an educational use. To that end, thermal performance and thermal discomfort probability analyses were performed for selected rooms, through experimental research based on computer simulations using EnergyPlus software. Results indicate a good contribution of the construction’s high thermal mass on reducing the indoor temperature fluctuation and a low occurrence of thermal discomfort periods, demonstrating the building’s suitability to modifications on its pattern of use occurred during its history. In the educational use the air change rates obtained per natural ventilation, however, were lower than the residential use, affecting the healthiness of users due to higher occupancy rate. A qualitative approach of the results enabled to highlight important thermal performance issues and singularities about the resiliency of historic buildings that changes its use over time.
id UNICAMP-20_fbe8332330c177fd972af469bd6f73e2
oai_identifier_str oai:ojs.periodicos.sbu.unicamp.br:article/8646323
network_acronym_str UNICAMP-20
network_name_str PARC (Campinas)
repository_id_str
spelling Thermal performance of FAU Maranhao building in two historic momentsDesempenho térmico do edifício da FAU Maranhão em dois momentos históricosBioclimatic architecture. Thermal comfort. Thermal performance. Thermal inertia. Historic building.Arquitetura bioclimática. Conforto térmico. Desempenho térmico. Inércia térmica. Edifício histórico.The FAU Maranhao building, beyond being an important architectural heritage of Sao Paulo city, is recognized for providing good environmental quality to its occupants. Since the building has already housed distinct uses, this paper presents studies that point out the thermal response of the building to the climate in which it is located, in two historical moments: right after its construction, which had a residential use, and nowadays, which has an educational use. To that end, thermal performance and thermal discomfort probability analyses were performed for selected rooms, through experimental research based on computer simulations using EnergyPlus software. Results indicate a good contribution of the construction’s high thermal mass on reducing the indoor temperature fluctuation and a low occurrence of thermal discomfort periods, demonstrating the building’s suitability to modifications on its pattern of use occurred during its history. In the educational use the air change rates obtained per natural ventilation, however, were lower than the residential use, affecting the healthiness of users due to higher occupancy rate. A qualitative approach of the results enabled to highlight important thermal performance issues and singularities about the resiliency of historic buildings that changes its use over time.A edificação da FAU Maranhão, além de ser um importante patrimônio arquitetônico da cidade de São Paulo, é reconhecida por prover boa qualidade ambiental aos seus usuários. Tendo em vista que a edificação já abrigou usos distintos, propôs-se a, neste artigo, apresentar estudos que demonstrem a resposta térmica da edificação ao clima em que está inserida, em dois momentos históricos: logo após sua construção, quando seu uso era residencial, e atualmente, em que seu uso é acadêmico. Para isso, realizaram-se análises de desempenho térmico e da probabilidade de ocorrência de desconforto térmico em ambientes selecionados, por meio de pesquisa experimental baseada em simulações computacionais desenvolvidas no software EnergyPlus. Os resultados mostraram uma boa contribuição da elevada inércia térmica da construção na redução da oscilação das temperaturas internas e uma baixa ocorrência de períodos em desconforto térmico,demonstrando adequabilidade da edificação para as alterações nos padrões de uso e ocupação ocorridas ao longo de sua história. As taxas de renovação de ar obtidas por ventilação natural mostraram-se, no entanto, bastante inferiores no uso acadêmico, o que pode prejudicar a salubridade dos usuários, devido à taxa de ocupação mais elevada. Uma abordagem qualitativa dos resultados permitiu destacar questões importantes sobre o desempenho térmico e peculiaridades referentes à resiliência de edificações históricas que passam por modificações de uso ao longo de sua história.Universidade Estadual de Campinas2016-12-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionCase studyinfo:eu-repo/semantics/otherapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/864632310.20396/parc.v7i4.8646323PARC Pesquisa em Arquitetura e Construção; Vol. 7 No. 4 (2016): An overview of the theme of environmental comfort; 211-224PARC Pesquisa em Arquitetura e Construção; Vol. 7 Núm. 4 (2016): Um panorama sobre a temática do Conforto Ambiental; 211-224PARC Pesquisa em Arquitetura e Construção; v. 7 n. 4 (2016): Um panorama sobre a temática do Conforto Ambiental; 211-2241980-6809reponame:PARC (Campinas)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPporhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8646323/15806Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construçãoinfo:eu-repo/semantics/openAccessNeves, Letícia de OliveiraMachado, Rodrigo DiasCavalcante, Rodrigo2017-05-22T10:54:03Zoai:ojs.periodicos.sbu.unicamp.br:article/8646323Revistahttp://periodicos.sbu.unicamp.br/ojs/index.php/parcPUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/oai||parc@fec.unicamp.br1980-68091980-6809opendoar:2017-05-22T10:54:03PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Thermal performance of FAU Maranhao building in two historic moments
Desempenho térmico do edifício da FAU Maranhão em dois momentos históricos
title Thermal performance of FAU Maranhao building in two historic moments
spellingShingle Thermal performance of FAU Maranhao building in two historic moments
Neves, Letícia de Oliveira
Bioclimatic architecture. Thermal comfort. Thermal performance. Thermal inertia. Historic building.
Arquitetura bioclimática. Conforto térmico. Desempenho térmico. Inércia térmica. Edifício histórico.
title_short Thermal performance of FAU Maranhao building in two historic moments
title_full Thermal performance of FAU Maranhao building in two historic moments
title_fullStr Thermal performance of FAU Maranhao building in two historic moments
title_full_unstemmed Thermal performance of FAU Maranhao building in two historic moments
title_sort Thermal performance of FAU Maranhao building in two historic moments
author Neves, Letícia de Oliveira
author_facet Neves, Letícia de Oliveira
Machado, Rodrigo Dias
Cavalcante, Rodrigo
author_role author
author2 Machado, Rodrigo Dias
Cavalcante, Rodrigo
author2_role author
author
dc.contributor.author.fl_str_mv Neves, Letícia de Oliveira
Machado, Rodrigo Dias
Cavalcante, Rodrigo
dc.subject.por.fl_str_mv Bioclimatic architecture. Thermal comfort. Thermal performance. Thermal inertia. Historic building.
Arquitetura bioclimática. Conforto térmico. Desempenho térmico. Inércia térmica. Edifício histórico.
topic Bioclimatic architecture. Thermal comfort. Thermal performance. Thermal inertia. Historic building.
Arquitetura bioclimática. Conforto térmico. Desempenho térmico. Inércia térmica. Edifício histórico.
description The FAU Maranhao building, beyond being an important architectural heritage of Sao Paulo city, is recognized for providing good environmental quality to its occupants. Since the building has already housed distinct uses, this paper presents studies that point out the thermal response of the building to the climate in which it is located, in two historical moments: right after its construction, which had a residential use, and nowadays, which has an educational use. To that end, thermal performance and thermal discomfort probability analyses were performed for selected rooms, through experimental research based on computer simulations using EnergyPlus software. Results indicate a good contribution of the construction’s high thermal mass on reducing the indoor temperature fluctuation and a low occurrence of thermal discomfort periods, demonstrating the building’s suitability to modifications on its pattern of use occurred during its history. In the educational use the air change rates obtained per natural ventilation, however, were lower than the residential use, affecting the healthiness of users due to higher occupancy rate. A qualitative approach of the results enabled to highlight important thermal performance issues and singularities about the resiliency of historic buildings that changes its use over time.
publishDate 2016
dc.date.none.fl_str_mv 2016-12-31
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Case study
info:eu-repo/semantics/other
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8646323
10.20396/parc.v7i4.8646323
url https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8646323
identifier_str_mv 10.20396/parc.v7i4.8646323
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8646323/15806
dc.rights.driver.fl_str_mv Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construção
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construção
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual de Campinas
publisher.none.fl_str_mv Universidade Estadual de Campinas
dc.source.none.fl_str_mv PARC Pesquisa em Arquitetura e Construção; Vol. 7 No. 4 (2016): An overview of the theme of environmental comfort; 211-224
PARC Pesquisa em Arquitetura e Construção; Vol. 7 Núm. 4 (2016): Um panorama sobre a temática do Conforto Ambiental; 211-224
PARC Pesquisa em Arquitetura e Construção; v. 7 n. 4 (2016): Um panorama sobre a temática do Conforto Ambiental; 211-224
1980-6809
reponame:PARC (Campinas)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str PARC (Campinas)
collection PARC (Campinas)
repository.name.fl_str_mv PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv ||parc@fec.unicamp.br
_version_ 1824498853626249216