Thermal performance of FAU Maranhao building in two historic moments
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | PARC (Campinas) |
Texto Completo: | https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8646323 |
Resumo: | The FAU Maranhao building, beyond being an important architectural heritage of Sao Paulo city, is recognized for providing good environmental quality to its occupants. Since the building has already housed distinct uses, this paper presents studies that point out the thermal response of the building to the climate in which it is located, in two historical moments: right after its construction, which had a residential use, and nowadays, which has an educational use. To that end, thermal performance and thermal discomfort probability analyses were performed for selected rooms, through experimental research based on computer simulations using EnergyPlus software. Results indicate a good contribution of the construction’s high thermal mass on reducing the indoor temperature fluctuation and a low occurrence of thermal discomfort periods, demonstrating the building’s suitability to modifications on its pattern of use occurred during its history. In the educational use the air change rates obtained per natural ventilation, however, were lower than the residential use, affecting the healthiness of users due to higher occupancy rate. A qualitative approach of the results enabled to highlight important thermal performance issues and singularities about the resiliency of historic buildings that changes its use over time. |
id |
UNICAMP-20_fbe8332330c177fd972af469bd6f73e2 |
---|---|
oai_identifier_str |
oai:ojs.periodicos.sbu.unicamp.br:article/8646323 |
network_acronym_str |
UNICAMP-20 |
network_name_str |
PARC (Campinas) |
repository_id_str |
|
spelling |
Thermal performance of FAU Maranhao building in two historic momentsDesempenho térmico do edifício da FAU Maranhão em dois momentos históricosBioclimatic architecture. Thermal comfort. Thermal performance. Thermal inertia. Historic building.Arquitetura bioclimática. Conforto térmico. Desempenho térmico. Inércia térmica. Edifício histórico.The FAU Maranhao building, beyond being an important architectural heritage of Sao Paulo city, is recognized for providing good environmental quality to its occupants. Since the building has already housed distinct uses, this paper presents studies that point out the thermal response of the building to the climate in which it is located, in two historical moments: right after its construction, which had a residential use, and nowadays, which has an educational use. To that end, thermal performance and thermal discomfort probability analyses were performed for selected rooms, through experimental research based on computer simulations using EnergyPlus software. Results indicate a good contribution of the construction’s high thermal mass on reducing the indoor temperature fluctuation and a low occurrence of thermal discomfort periods, demonstrating the building’s suitability to modifications on its pattern of use occurred during its history. In the educational use the air change rates obtained per natural ventilation, however, were lower than the residential use, affecting the healthiness of users due to higher occupancy rate. A qualitative approach of the results enabled to highlight important thermal performance issues and singularities about the resiliency of historic buildings that changes its use over time.A edificação da FAU Maranhão, além de ser um importante patrimônio arquitetônico da cidade de São Paulo, é reconhecida por prover boa qualidade ambiental aos seus usuários. Tendo em vista que a edificação já abrigou usos distintos, propôs-se a, neste artigo, apresentar estudos que demonstrem a resposta térmica da edificação ao clima em que está inserida, em dois momentos históricos: logo após sua construção, quando seu uso era residencial, e atualmente, em que seu uso é acadêmico. Para isso, realizaram-se análises de desempenho térmico e da probabilidade de ocorrência de desconforto térmico em ambientes selecionados, por meio de pesquisa experimental baseada em simulações computacionais desenvolvidas no software EnergyPlus. Os resultados mostraram uma boa contribuição da elevada inércia térmica da construção na redução da oscilação das temperaturas internas e uma baixa ocorrência de períodos em desconforto térmico,demonstrando adequabilidade da edificação para as alterações nos padrões de uso e ocupação ocorridas ao longo de sua história. As taxas de renovação de ar obtidas por ventilação natural mostraram-se, no entanto, bastante inferiores no uso acadêmico, o que pode prejudicar a salubridade dos usuários, devido à taxa de ocupação mais elevada. Uma abordagem qualitativa dos resultados permitiu destacar questões importantes sobre o desempenho térmico e peculiaridades referentes à resiliência de edificações históricas que passam por modificações de uso ao longo de sua história.Universidade Estadual de Campinas2016-12-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionCase studyinfo:eu-repo/semantics/otherapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/864632310.20396/parc.v7i4.8646323PARC Pesquisa em Arquitetura e Construção; Vol. 7 No. 4 (2016): An overview of the theme of environmental comfort; 211-224PARC Pesquisa em Arquitetura e Construção; Vol. 7 Núm. 4 (2016): Um panorama sobre a temática do Conforto Ambiental; 211-224PARC Pesquisa em Arquitetura e Construção; v. 7 n. 4 (2016): Um panorama sobre a temática do Conforto Ambiental; 211-2241980-6809reponame:PARC (Campinas)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPporhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8646323/15806Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construçãoinfo:eu-repo/semantics/openAccessNeves, Letícia de OliveiraMachado, Rodrigo DiasCavalcante, Rodrigo2017-05-22T10:54:03Zoai:ojs.periodicos.sbu.unicamp.br:article/8646323Revistahttp://periodicos.sbu.unicamp.br/ojs/index.php/parcPUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/parc/oai||parc@fec.unicamp.br1980-68091980-6809opendoar:2017-05-22T10:54:03PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP)false |
dc.title.none.fl_str_mv |
Thermal performance of FAU Maranhao building in two historic moments Desempenho térmico do edifício da FAU Maranhão em dois momentos históricos |
title |
Thermal performance of FAU Maranhao building in two historic moments |
spellingShingle |
Thermal performance of FAU Maranhao building in two historic moments Neves, Letícia de Oliveira Bioclimatic architecture. Thermal comfort. Thermal performance. Thermal inertia. Historic building. Arquitetura bioclimática. Conforto térmico. Desempenho térmico. Inércia térmica. Edifício histórico. |
title_short |
Thermal performance of FAU Maranhao building in two historic moments |
title_full |
Thermal performance of FAU Maranhao building in two historic moments |
title_fullStr |
Thermal performance of FAU Maranhao building in two historic moments |
title_full_unstemmed |
Thermal performance of FAU Maranhao building in two historic moments |
title_sort |
Thermal performance of FAU Maranhao building in two historic moments |
author |
Neves, Letícia de Oliveira |
author_facet |
Neves, Letícia de Oliveira Machado, Rodrigo Dias Cavalcante, Rodrigo |
author_role |
author |
author2 |
Machado, Rodrigo Dias Cavalcante, Rodrigo |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Neves, Letícia de Oliveira Machado, Rodrigo Dias Cavalcante, Rodrigo |
dc.subject.por.fl_str_mv |
Bioclimatic architecture. Thermal comfort. Thermal performance. Thermal inertia. Historic building. Arquitetura bioclimática. Conforto térmico. Desempenho térmico. Inércia térmica. Edifício histórico. |
topic |
Bioclimatic architecture. Thermal comfort. Thermal performance. Thermal inertia. Historic building. Arquitetura bioclimática. Conforto térmico. Desempenho térmico. Inércia térmica. Edifício histórico. |
description |
The FAU Maranhao building, beyond being an important architectural heritage of Sao Paulo city, is recognized for providing good environmental quality to its occupants. Since the building has already housed distinct uses, this paper presents studies that point out the thermal response of the building to the climate in which it is located, in two historical moments: right after its construction, which had a residential use, and nowadays, which has an educational use. To that end, thermal performance and thermal discomfort probability analyses were performed for selected rooms, through experimental research based on computer simulations using EnergyPlus software. Results indicate a good contribution of the construction’s high thermal mass on reducing the indoor temperature fluctuation and a low occurrence of thermal discomfort periods, demonstrating the building’s suitability to modifications on its pattern of use occurred during its history. In the educational use the air change rates obtained per natural ventilation, however, were lower than the residential use, affecting the healthiness of users due to higher occupancy rate. A qualitative approach of the results enabled to highlight important thermal performance issues and singularities about the resiliency of historic buildings that changes its use over time. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-12-31 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Case study info:eu-repo/semantics/other |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8646323 10.20396/parc.v7i4.8646323 |
url |
https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8646323 |
identifier_str_mv |
10.20396/parc.v7i4.8646323 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/parc/article/view/8646323/15806 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construção info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2018 PARC Pesquisa em Arquitetura e Construção |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
dc.source.none.fl_str_mv |
PARC Pesquisa em Arquitetura e Construção; Vol. 7 No. 4 (2016): An overview of the theme of environmental comfort; 211-224 PARC Pesquisa em Arquitetura e Construção; Vol. 7 Núm. 4 (2016): Um panorama sobre a temática do Conforto Ambiental; 211-224 PARC Pesquisa em Arquitetura e Construção; v. 7 n. 4 (2016): Um panorama sobre a temática do Conforto Ambiental; 211-224 1980-6809 reponame:PARC (Campinas) instname:Universidade Estadual de Campinas (UNICAMP) instacron:UNICAMP |
instname_str |
Universidade Estadual de Campinas (UNICAMP) |
instacron_str |
UNICAMP |
institution |
UNICAMP |
reponame_str |
PARC (Campinas) |
collection |
PARC (Campinas) |
repository.name.fl_str_mv |
PARC (Campinas) - Universidade Estadual de Campinas (UNICAMP) |
repository.mail.fl_str_mv |
||parc@fec.unicamp.br |
_version_ |
1824498853626249216 |