Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio

Detalhes bibliográficos
Autor(a) principal: Lombardelli, Karen Vicencia Pingarilho
Data de Publicação: 2008
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
Texto Completo: https://hdl.handle.net/20.500.12733/1607812
Resumo: Orientador: Luiz Carlos Zeferino
id UNICAMP-30_2370393e0825c0ad4629b1787a52354b
oai_identifier_str oai::432052
network_acronym_str UNICAMP-30
network_name_str Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
repository_id_str
spelling Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrioLimited-sequences of magnetic resonance imaging in assessing the extent of endometrial carcinomaNeoplasias do endométrioImagem de ressonância magnéticaEndometrial carcinomaMagnetic resonance imagingOrientador: Luiz Carlos ZeferinoDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias MedicasResumo: Introdução: A ressonância magnética (RM) é um exame que pode auxiliar no estadiamento pré-cirúrgico da paciente com carcinoma de endométrio, o que permite planejar mais adequadamente a cirurgia, principalmente quando há evidências de doença avançada e em mulheres com comorbidades clínicas relevantes. Todavia, é um exame demorado, exige cooperação e imobilidade, emite ruído e o espaço físico é restrito, ocasionando desconforto e claustrofobia. Motivos referidos, inclusive como justificativa de interrupção do exame. A mobilidade durante o exame, incluindo movimentos respiratórios acentuados, assim como o alto índice de obesidade em mulheres com carcinoma de endométrio podem gerar artefatos que comprometem a qualidade da imagem, prejudicado o diagnóstico final. Simplificar o exame com redução do tempo de duração sem prejudicar a qualidade do diagnóstico seria muito útil. Objetivos: O objetivo deste estudo foi avaliar se a subtração das seqüências T1 FS sagital e T2 TSE coronal, sem contraste e com aquisições de alta resolução, comprometeria o desempenho diagnóstico na avaliação da extensão do carcinoma de endométrio. Material e Métodos: Este estudo foi observacional e descritivo, de corte transversal. Foram incluídas 62 mulheres com diagnóstico histológico de carcinoma de endométrio. As pacientes fizeram RM da pelve que foi analisada por dois médicos especialistas, sendo que um avaliou o exame completo e o outro o exame resumido, sem troca de informações entre eles. Os achados da RM completa e resumida foram comparados com os laudos anatomopatológicos. Para testar a associação entre as variáveis qualitativas foi utilizado o teste qui-quadrado. A concordância diagnóstica entre os exames completo e resumido da RM foi analisada pelo Coeficiente de Kappa. Resultados: As medianas, médias, desvios-padrão e valores máximos das medidas do maior diâmetro do tumor avaliadas pelas RMC, RMR e patologia foram muito próximas. As medianas, médias, desvios-padrão, valores mínimos e valores máximos do volume do tumor avaliado pelas RMC e RMR foram muito próximos. A mediana do volume do tumor avaliado pela patologia foi muito próxima das medianas obtidas pela ressonância magnética, enquanto que a média, desvio-padrão e valor máximo apresentaram valores maiores. Conclusões: A RMR apresenta desempenho semelhante ao da RMC na avaliação da extensão do carcinoma do endométrio. A concordâncJa observada para avaliação da invasão, miometrial, do colo do útero e dos linfonodos pélvicos foi classificada como muito boa ou excelente. A concordância na avaliação da invasão do colo do útero entre a patologia e as RMC e RMR foi classificada como muito boa (Tabela 2). A concordância observada para avaliação das invasões miometrial e do colo do útero entre os exames de RM foi classificada como muito boa ou excelente. Portanto, é possível utilizar o exame de RM sem as seqüências T1 SE sagital sem contraste e T2 TSE caronal, pois não haverá prejuízo na qualidade do diagnósticoAbstract: Background: Magnetic resonance imaging (MRI) is an exam that may be helpful in establishing presurgical staging of patients with endometrial carcinoma, allowing a more appropriate surgical procedure to be planned, principally in the case of advanced disease or in women with relevant clinical comorbidities. However, it is a protracted exam that requires cooperation and immobility. In addition, it is noisy and physical space is restricted, often causing discomfort, anxiety and claustrophobia that may lead to interruption of the exam. Movements including accentuated breathing may generate artifacts that compromise the quality of images. Simplifying the exam by reducing the time required to carry it out without affecting the quality of diagnosis would be extremely useful. Objectives: To evaluate whether modification to the routine MRI (complete MRI) by eliminating the non contrast high resolution sagittal T1-weighted FS and caronal T2-weighted TSE sequences (resumed MRI), negatively affects performance of this exam in the diagnosis of the extent of endometrial carcinoma. Methods: A cross sectional, observational, descriptive study was carried out in 62 women with endometrial carcinoma. All underwent pelvic MRI, which was analyzed by two radiologists. Complete and rapid MRI findings were compared with anatomopathology reports. The chi-square test was used to test the association between qualitative variables. Diagnostic agreement between complete and resumed MRI was analyzed using the kappa coefficient. Results: There were no statistically significant differences in the medians, means, standard deviations or maximum values of the measurements of the greatest diameter and of tumor volume as evaluated by complete MRI, resumed MRI and pathology. With respect to myometrial invasion, agreement between complete and resumed MRI was classified as very good, with a kappa coefficient of 0.73 (0.54 - 0.93). Agreement in the evaluation of myometrial invasion between pathology and complete or resumed MRI was classified as good. With respect to cervical invasion, agreement between complete and rapid MRI was classified as excellent, with a kappa coefficient of 0.96 (0.87 - 1.00). Agreement in the evaluation of cervical invasion between pathology and complete and resumed MRI was classified as very good. With respect to pelvic Iymph nodes, agreement between complete and resumed MRI was classified as excellent, with kappa coefficients of 0.93 (0.84 - 1.00) and 0.96 (0.90 - 1.00), respectively. Conclusions: MRI without the non-contrast sagittal T1-weighted SE and coronal T2-weighted TSE sequences maintains the same performance as complete MRI in evaluating the extent of endometrial carcinoma. The shorter time required to carry out the exam would, therefore, be beneficial to the patients, reducing their discomfort and, principally, decreasing reactions of anxiety and claustrophobia. Moreover, costs to healthcare services, and indirectly to the patients, would also be reduced, since the productivity of the equipment and the team would be higherMestradoCiências BiomédicasMestre em Tocoginecologia[s.n.]Zeferino, Luiz Carlos, 1955-Derchain, Sophie Françoise MauricetteKoch, Hilton AugustoUniversidade Estadual de Campinas (UNICAMP). Faculdade de Ciências MédicasPrograma de Pós-Graduação em TocoginecologiaUNIVERSIDADE ESTADUAL DE CAMPINASLombardelli, Karen Vicencia Pingarilho20082008-08-27T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdf68f. : il.https://hdl.handle.net/20.500.12733/1607812LOMBARDELLI, Karen Vicencia Pingarilho. Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio. 2008. 68f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1607812. Acesso em: 2 set. 2024.https://repositorio.unicamp.br/acervo/detalhe/432052porreponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPinfo:eu-repo/semantics/openAccess2017-02-18T05:18:10Zoai::432052Biblioteca Digital de Teses e DissertaçõesPUBhttp://repositorio.unicamp.br/oai/tese/oai.aspsbubd@unicamp.bropendoar:2017-02-18T05:18:10Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio
Limited-sequences of magnetic resonance imaging in assessing the extent of endometrial carcinoma
title Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio
spellingShingle Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio
Lombardelli, Karen Vicencia Pingarilho
Neoplasias do endométrio
Imagem de ressonância magnética
Endometrial carcinoma
Magnetic resonance imaging
title_short Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio
title_full Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio
title_fullStr Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio
title_full_unstemmed Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio
title_sort Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio
author Lombardelli, Karen Vicencia Pingarilho
author_facet Lombardelli, Karen Vicencia Pingarilho
author_role author
dc.contributor.none.fl_str_mv Zeferino, Luiz Carlos, 1955-
Derchain, Sophie Françoise Mauricette
Koch, Hilton Augusto
Universidade Estadual de Campinas (UNICAMP). Faculdade de Ciências Médicas
Programa de Pós-Graduação em Tocoginecologia
UNIVERSIDADE ESTADUAL DE CAMPINAS
dc.contributor.author.fl_str_mv Lombardelli, Karen Vicencia Pingarilho
dc.subject.por.fl_str_mv Neoplasias do endométrio
Imagem de ressonância magnética
Endometrial carcinoma
Magnetic resonance imaging
topic Neoplasias do endométrio
Imagem de ressonância magnética
Endometrial carcinoma
Magnetic resonance imaging
description Orientador: Luiz Carlos Zeferino
publishDate 2008
dc.date.none.fl_str_mv 2008
2008-08-27T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/20.500.12733/1607812
LOMBARDELLI, Karen Vicencia Pingarilho. Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio. 2008. 68f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1607812. Acesso em: 2 set. 2024.
url https://hdl.handle.net/20.500.12733/1607812
identifier_str_mv LOMBARDELLI, Karen Vicencia Pingarilho. Ressonancia magnetica resumida na avaliação da extensão do carcinoma de endometrio. 2008. 68f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1607812. Acesso em: 2 set. 2024.
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://repositorio.unicamp.br/acervo/detalhe/432052
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
68f. : il.
dc.publisher.none.fl_str_mv [s.n.]
publisher.none.fl_str_mv [s.n.]
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
collection Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv sbubd@unicamp.br
_version_ 1809188992477822976