Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p.

Detalhes bibliográficos
Autor(a) principal: Nakaoka, Marcia Mika
Data de Publicação: 2007
Tipo de documento: Tese
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
Texto Completo: https://hdl.handle.net/20.500.12733/1605670
Resumo: Orientador: Marcelo Ferraz Mesquita
id UNICAMP-30_7352423ad8700a8e624111821ce04216
oai_identifier_str oai::409619
network_acronym_str UNICAMP-30
network_name_str Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
repository_id_str
spelling Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p.The influence of the veneering application and Spark erosion on the misfit level of implant-supported frameworksProtese dentária fixada por implanteCerâmica odontológicaResinas acrílicasDental prosthesisDental ceramicsAcrylic resinsOrientador: Marcelo Ferraz MesquitaTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de PiracicabaResumo: As distorções oriundas das técnicas de aplicação de revestimentos estéticos sobre infra-estruturas metálicas de próteses fixas podem resultar em margens cervicais desadaptadas. Dessa forma, este trabalho propôs-se a avaliar o efeito do tipo de revestimento estético, da simulação dos ciclos de cocção da cerâmica, e da aplicação da eletroerosão, sobre o desajuste de infra-estruturas implanto-suportadas fundidas em titânio comercialmente puro (Ti c.p.). Foi utilizada uma matriz metálica contendo 5 pilares intermediários do tipo Microunit. Sobre ela, foram enceradas 40 infra-estruturas, posteriormente fundidas em Ti c.p. (Tritan, Dentaurum, Alemanha). Para cada infraestrutura foi confeccionado um index, com 5 análogos parafusados em cada infra-estrutura. Esse conjunto foi posicionado em microscópio para a mensuração dos desajustes antes da aplicação dos revestimentos estéticos, com a finalidade de avaliar apenas desajuste provocado pela aplicação dos revestimentos estéticos e pelo ciclo de cocção da cerâmica. As infra-estruturas foram separadas, aleatoriamente: G1: resina acrílica ativada termicamente (Clássico, Clássico Artigos Odontológicos Ltda., São Paulo, Brasil); G2: resina fotopolimerizável (Versyo.com, Heraeus Kulzer, Brasil); G3: cerâmica (Triceram, Dentaurum J. P. Winkelstroeter KG ¿ Pforzheim - Alemanha); G4: simulação dos ciclos de cocção da cerâmica. Novamente, após a aplicação dos revestimentos estéticos, foi realizada a avaliação do desajuste marginal sobre o index. Procedeu-se o processo de eletroerosão (Tel Med Technologies, Port Huron, Michigan, EUA). As leituras de desajuste foram realizadas após o aperto com 10 Ncm em um único parafuso, correspondente ao implante A. Através desse procedimento, verificou-se a adaptação dos componentes C e E. O procedimento foi repetido com o outro implante mais distal (E), para mensuração nos implantes A e C. As leituras foram realizadas utilizando microscópio mensurador, com aumento de 120X e precisão de 0,5µm (Micro Vision ¿ Leika, Wetzlar, Alemanha), antes e após aplicação dos revestimentos estéticos, e após o processo de eletroerosão. Os resultados obtidos foram submetidos à Análise de Variância e ao teste de Tukey (p<0,05). Os valores de desajuste marginal das infra-estruturas antes da aplicação dos revestimentos estéticos não apresentaram diferença estatística significante entre si: G1: 29,81 'mu' (+ 10,66); G2: 35,30 'mu' (+ 12,15); G3: 44,75 'mu'(+ 13,73); G4: 38,57 'mu' (+ 16,94). A aplicação dos revestimentos estéticos e a simulação dos ciclos de cocção da cerâmica aumentaram significantemente os valores médios de desajuste marginal para todos os grupos: G1: 221,70 'mu' (+14,11); G2: 81,91 'mu' (+15,71); G3: 233,99 'mu' (+39,18); e G4: 119,75 'mu' (+38,08). Os grupos G1 e G3 não apresentaram diferença estatisticamente significante entre si, mas apresentaram diferença quando comparados aos G2 e G4. Após o processo de eletroerosão, apenas para o grupo G3: 161,16 µm (+36,59 ) a média de desajuste marginal apresentou-se com valor significamente menor. As médias de desajuste marginal para os grupos G1: 198,68 mu' (+34,19); G2: 62,03 'mu' (+17,73) e G4: 87,98 'mu' (+39,32) foram numericamente menores, porém, sem diferença estatística. Como ocorrido anteriormente, os grupos G1 e G3 não apresentaram diferença estatística significante, mas ambos apresentaram diferença quando comparados aos grupos G2 e G4. A partir dos resultados obtidos no presente estudo, conclui-se que os revestimentos estéticos em resina acrílica ativada termicamente e em cerâmica produziram os maiores valores de desajuste marginal para próteses implanto-retidas, enquanto a resina fotopolimerizável, os menores. A aplicação de cerâmica nas infra-estruturas produziu maiores valores de desajuste marginal quando comparado à simples simulação dos ciclos de cocção. O processo de eletroerosão mostrou-se eficaz na redução dos desajustes marginais apenas para o grupo com aplicação da cerâmicaAbstract: The demand for a passive fit of frameworks for osseointegrated endousseous implants abutments is well known, because the tightening of an inaccurate framework to the abutments can transmit stress to the bone-metal interface. The purpose of the present study was to evaluate the influence of the veneering application and porcelain firing cycle on the misfit level of implant-supported frameworks. Forty Ti c.p. (Tritan, Dentaurum, Germany) alloy frameworks were fabricated from a metallic index containing 5 Branemark type multi unit abutments. Analogs of the abutments were positioned to the framework, to construct an index for each framework. This index allowed the observation of the marginal gaps caused by the application of the veneering material. The frameworks were grouped (n=10): 1) heat acrylic resin (Clássico, Clássico, São Paulo, Brazil); 2) light polymerized resin (Versyo.com, Heraeus Kulzer, Brazil); 3) porcelain application (Triceram, Dentaurum - Germany); 4) simulation of porcelain firing cycle. Marginal refinement with spark erosion was conducted on specific equipment (Tel Med Technologies, U.S.A.). The marginal gap was obtained before and after the veneering materials and the spark erosion procedure, following the single screw test protocol (using a tightening force of 10 Ncm). A traveling microscope (STN ¿ Olympus Optical Co. Ltd Japan (120X) was used, tightening 10N in the titanium screw of the extremity distal implant, measuring the gaps at the central and distal implants. Data were subject Analysis of Variance followed by Tukey test (5%). Marginal gap mean values of the frameworks before the veneering application were not significantly different: G1: 29.81 'mu' (+ 10.66); G2: 35.30 'mu' (+ 12.15); G3: 44.75 'mu' (+13.73); G4: 38.57 'mu' (+ 16.94). The application veneering materials and the simulation of porcelain firing cycle increased significantly the misfit mean values of all groups: G1: 221.70 'mu' (+14.11); G2: 81.91 'mu' (+15.71); G3: 233.99 'mu' (+39.18); e G4: 119.75 'mu' (+38.08). There were no significant differences between G1 and G3, but they were significantly different from both G2 and G3. After the spark erosion process, marginal gap mean value decreased significantly only G3 group: 161.16 µm (+36.59). G1: 198.68 'mu' (+34.19); G2: 62.03 'mu' (+17.73) and G4: 87.98 'mu' (+39.32) groups decreased the marginal gap mean values, but not significantly after the spark erosion procedure. As occurred after the application of veneering materials, G1 and G3 groups did not show significant difference, but they both were significantly different from G2 and G4 groups. It can be concluded that heat cured acrylic resin and porcelain produced the highest mean values of marginal gaps, while light cured acrylic resin, the lowest. The application of porcelain produced higher misfit values than the simulation of porcelain firing cycles. After the spark erosion process, marginal gap mean value decreased significantly only porcelain application grouDoutoradoPrótese DentalMestre em Clínica Odontológica[s.n.]Mesquita, Marcelo Ferraz, 1967-Giampaolo, Eunice TeresinhaCompagnoni, Marco AntonioNóbilo, Mauro Antonio de ArrudaConsani, Rafael Leonardo XediekUniversidade Estadual de Campinas. Faculdade de Odontologia de PiracicabaPrograma de Pós-Graduação em Clínica OdontológicaUNIVERSIDADE ESTADUAL DE CAMPINASNakaoka, Marcia Mika20072007-06-22T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdf86f. : il.(Broch.)https://hdl.handle.net/20.500.12733/1605670NAKAOKA, Marcia Mika. Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p. 2007. 86f. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: https://hdl.handle.net/20.500.12733/1605670. Acesso em: 15 mai. 2024.https://repositorio.unicamp.br/acervo/detalhe/409619porreponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPinfo:eu-repo/semantics/openAccess2017-02-18T04:59:23Zoai::409619Biblioteca Digital de Teses e DissertaçõesPUBhttp://repositorio.unicamp.br/oai/tese/oai.aspsbubd@unicamp.bropendoar:2017-02-18T04:59:23Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p.
The influence of the veneering application and Spark erosion on the misfit level of implant-supported frameworks
title Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p.
spellingShingle Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p.
Nakaoka, Marcia Mika
Protese dentária fixada por implante
Cerâmica odontológica
Resinas acrílicas
Dental prosthesis
Dental ceramics
Acrylic resins
title_short Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p.
title_full Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p.
title_fullStr Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p.
title_full_unstemmed Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p.
title_sort Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p.
author Nakaoka, Marcia Mika
author_facet Nakaoka, Marcia Mika
author_role author
dc.contributor.none.fl_str_mv Mesquita, Marcelo Ferraz, 1967-
Giampaolo, Eunice Teresinha
Compagnoni, Marco Antonio
Nóbilo, Mauro Antonio de Arruda
Consani, Rafael Leonardo Xediek
Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba
Programa de Pós-Graduação em Clínica Odontológica
UNIVERSIDADE ESTADUAL DE CAMPINAS
dc.contributor.author.fl_str_mv Nakaoka, Marcia Mika
dc.subject.por.fl_str_mv Protese dentária fixada por implante
Cerâmica odontológica
Resinas acrílicas
Dental prosthesis
Dental ceramics
Acrylic resins
topic Protese dentária fixada por implante
Cerâmica odontológica
Resinas acrílicas
Dental prosthesis
Dental ceramics
Acrylic resins
description Orientador: Marcelo Ferraz Mesquita
publishDate 2007
dc.date.none.fl_str_mv 2007
2007-06-22T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv (Broch.)
https://hdl.handle.net/20.500.12733/1605670
NAKAOKA, Marcia Mika. Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p. 2007. 86f. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: https://hdl.handle.net/20.500.12733/1605670. Acesso em: 15 mai. 2024.
identifier_str_mv (Broch.)
NAKAOKA, Marcia Mika. Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p. 2007. 86f. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: https://hdl.handle.net/20.500.12733/1605670. Acesso em: 15 mai. 2024.
url https://hdl.handle.net/20.500.12733/1605670
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://repositorio.unicamp.br/acervo/detalhe/409619
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
86f. : il.
dc.publisher.none.fl_str_mv [s.n.]
publisher.none.fl_str_mv [s.n.]
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
collection Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv sbubd@unicamp.br
_version_ 1799138431250464768