Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'

Detalhes bibliográficos
Autor(a) principal: Di Iglia, Rosana Aparecida
Data de Publicação: 2002
Tipo de documento: Tese
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
Texto Completo: https://hdl.handle.net/20.500.12733/1603209
Resumo: Orientador: Rodnei Bertazzoli
id UNICAMP-30_7b3634a29ddcd8ee67f606c5865c0daa
oai_identifier_str oai::373637
network_acronym_str UNICAMP-30
network_name_str Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
repository_id_str
spelling Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'Eletrochemical removal of phenol from aqueous effluents by using a flow cell with a DSA type three dimensional anodeFenóisOxidação eletrolíticaResiduos orgânicosÁguas residuaisPhenolsElectrolytic oxidationOrganic wastesSewageOrientador: Rodnei BertazzoliTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia MecanicaResumo: Os compostos fenólicos são amplamente utilizados, principalmente na produção de plásticos, resinas e na indústria petroquímica, gerando efluentes com alta toxicidade. Os tratamentos existentes, embora eficientes, demandam adição de grandes quantidades de reagentes, no caso da oxidação química, ou grandes áreas físicas, longos tempo de retenção e difícil controle do processo, no caso da degradação biológica. O objetivo deste trabalho é desenvolver e otimizar dois reatores eletroquímicos de fluxo utilizando anodos comerciais de óxidos de metais nobres para eletroxidação de fenol: um com anodo plano e outro com anodo tridimensional sendo ambos do tipo ADE® de Ti/RuO2 - TiO2. A inovação tecnológica deste processo de tratamento consiste no uso destes anodos usados em larga escala na indústria de álcalis e que além da alta resistência à corrosão e da boa atividade catalítica, podem ser confeccionados em diversos formatos e tamanhos. Este projeto foi desenvolvido em 4 etapas: 1) Construção dos reatores; 2) Estudo voltamétrico das reações do eletrodo; 3) Ensaios de eletroxidação de fenol e 4) Comparação do desempenho dos reatores. A caracterização e análise elementar do eletrodo tridimensional por MEV determinou sua composição como (TiO2)0,67-(RuO2)0,33 (mol%). Os ensaios de voltametria permitiram a atribuição de 3 picos das principais transições do rutênio, com base na literatura, para o eletrodo plano já que para o tridimensional estes picos foram suprimidos. Foi feita uma estimativa da área do eletrodo tridimensional como cerca de 3 a 4 vezes a área do plano. Foram iniciados então, os ensaios de eletroxidação de fenol nos reatores construídos em regime de recirculação. Avaliou-se a influência do potencial aplicado, da velocidade linear do fluido no reator sobre a constante cinética (KFAe) de oxidação de fenol e o consumo de energia elétrica. Sobrepotenciais mais positivos conduziram a maiores taxas de conversão de fenol atingindo um máximo em 2,5V. Com este sobrepotencial, o reator com anodo tridimensional apresentou uma taxa de 100% de conversão de fenol em apenas 3 horas de tratamento, enquanto que o reator com anodo plano atingiu 50 % de conversão em 3 horas e 62% em 5 horas de experimento. O mesmo comportamento foi observado para a redução de COT e DQO. O estudo da influência da velocidade linear para o reator com anodo tridimensional demonstra que a velocidade de eletroxidação de fenol aumenta quando a velocidade linear diminui, indicando que o tempo de residência da solução dentro do reator influencia no processo de eletroxidação de fenol. Este fato foi confirmado pela análise cinética e pelo monitoramento dos teores de COT e DQO, onde maiores valores de KFAe maiores reduções de COT e DQO foram obtidos para menores velocidades lineares. Para o reator com anodo plano não foi possível estabelecer uma tendência da velocidade de eletroxidação apenas com as curvas de decaimento, porém o cálculo das constantes cinéticas e a análise de COT e DQO demonstraram que velocidades lineares menores conduziram a resultados melhores. Com o anodo tridimensional, foi realizada uma estimativa de custo de processo para o potencial de 1,63V no qual 80% de fenol foi degradado. Nestas condições experimentais, obtém-se um consumo de 675 kWh.kg-1. No Brasil o valor médio do kWh industrial é de US$ 0,02, US$ 13,5 seria o custo da degradação de 1 kg of Fenol. Por este valor, poderiam ser tratados 10.000L de solução no caso de uma solução com concentração fenol de 100 mg.L-1. Comparando-se com o tratamento convencional de biodegração, o tratamento eletroquímico continua apresentando um custo alto, sendo assim ainda é necessário buscar melhorias no processo que conduzam a eficiência maior e diminuam o custo do processoAbstract: Phenolic compounds are widely used by petrochemical industry. Plastics and resins manufacturing are responsible for the generation of large amounts of aqueous effluents containing phenol. Conventional biological treatment is a low yield process that demands large ponds and its operation generates huge amounts of sludge. Furthermore, chemical treatments present the drawback of storing and handling hazardous reactants. In this work an electrochemical process for phenol removal was designed and optimized. A flow cell reactor was developed using a flat and a three dimensional commercial oxide anodes, coated with RuO2 - TiO2. The whole investigation was carried out in four phases and comprised: 1. Flow reactor designing and setting up; 2. Voltammetric identification of redox couples of the anode coating; 3. Degradation of phenol solutions by controlled potential bulk electrolysis; 4. Reactors comparative performance study. Anodes oxide coating structure and composition were determined by MEV-EDS which revealed cracked-mud like topology with composition of (TiO2)0,67-(RuO2)0,33 (mol%). Voltammetric experiments identified three rutenium redox couples in the oxide coating. Based on the oxygen evolution reaction currents, the three-dimensional electrode area shown to be three times greater than the flat electrode area. In the controlled potential electrolysis, the role of potential and flow rate were evaluated and kinetic analysis of the electrochemical process lead to the calculation of the phenol degradation rate constants as a function of the variables above. By using potential of 2.5 V vs SCE, 100% of phenol present in solution was degraded in three hours of processing when the three dimensional electrode was mounted in the reactor. By using the flat anode only 50% was removed in the same experiment time. Similar behavior was observed for TOC and COD reduction. In the experiments in which the flow rate was used as the independent variable, it was observed that increased values of flow rate causes a reduction of phenol degradation rate. Kinetic analysis confirmed the observation, point to the conclusion that higher residence times increased the phenol conversion rate. By considering the energy consumption for a process conducted at 1.63 V, 675 kWh kg-1 of phenol was spent. Considering an average value for the kWh of US$ 0.02, 1Kg of phenol can be degraded by a cost of US$ 13.5. This means that 10,000 L of solution containing 100 mg L-1 of phenol can be treated by this price. By comparing with the cost of a biological treatment, further improvements are necessary prior to scale up the electrochemical process for industrial effluent treatmentDoutoradoMateriais e Processos de FabricaçãoDoutor em Engenharia Mecânica[s.n.]Bertazzoli, Rodnei, 1965-Souza, Jurandir Rodrigues deSilva, Meuris Gurgel Carlos daRohwedder, Jarbas José RodriguesFreire, Celia Marina de AlvarengaUniversidade Estadual de Campinas (UNICAMP). Faculdade de Engenharia MecânicaPrograma de Pós-Graduação em Engenharia MecânicaUNIVERSIDADE ESTADUAL DE CAMPINASDi Iglia, Rosana Aparecida20022002-12-18T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdf116p. : il.(Broch.)https://hdl.handle.net/20.500.12733/1603209DI IGLIA, Rosana Aparecida. Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'. 2002. 116p. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1603209. Acesso em: 2 set. 2024.https://repositorio.unicamp.br/acervo/detalhe/373637porreponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPinfo:eu-repo/semantics/openAccess2017-02-18T04:37:01Zoai::373637Biblioteca Digital de Teses e DissertaçõesPUBhttp://repositorio.unicamp.br/oai/tese/oai.aspsbubd@unicamp.bropendoar:2017-02-18T04:37:01Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'
Eletrochemical removal of phenol from aqueous effluents by using a flow cell with a DSA type three dimensional anode
title Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'
spellingShingle Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'
Di Iglia, Rosana Aparecida
Fenóis
Oxidação eletrolítica
Residuos orgânicos
Águas residuais
Phenols
Electrolytic oxidation
Organic wastes
Sewage
title_short Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'
title_full Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'
title_fullStr Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'
title_full_unstemmed Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'
title_sort Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'
author Di Iglia, Rosana Aparecida
author_facet Di Iglia, Rosana Aparecida
author_role author
dc.contributor.none.fl_str_mv Bertazzoli, Rodnei, 1965-
Souza, Jurandir Rodrigues de
Silva, Meuris Gurgel Carlos da
Rohwedder, Jarbas José Rodrigues
Freire, Celia Marina de Alvarenga
Universidade Estadual de Campinas (UNICAMP). Faculdade de Engenharia Mecânica
Programa de Pós-Graduação em Engenharia Mecânica
UNIVERSIDADE ESTADUAL DE CAMPINAS
dc.contributor.author.fl_str_mv Di Iglia, Rosana Aparecida
dc.subject.por.fl_str_mv Fenóis
Oxidação eletrolítica
Residuos orgânicos
Águas residuais
Phenols
Electrolytic oxidation
Organic wastes
Sewage
topic Fenóis
Oxidação eletrolítica
Residuos orgânicos
Águas residuais
Phenols
Electrolytic oxidation
Organic wastes
Sewage
description Orientador: Rodnei Bertazzoli
publishDate 2002
dc.date.none.fl_str_mv 2002
2002-12-18T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv (Broch.)
https://hdl.handle.net/20.500.12733/1603209
DI IGLIA, Rosana Aparecida. Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'. 2002. 116p. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1603209. Acesso em: 2 set. 2024.
identifier_str_mv (Broch.)
DI IGLIA, Rosana Aparecida. Remoção eletroquimica de fenol em efluentes aquosos utilizando celula de fluxo com anodo tridimensional do tipo ADE'Marca Registrada'. 2002. 116p. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1603209. Acesso em: 2 set. 2024.
url https://hdl.handle.net/20.500.12733/1603209
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://repositorio.unicamp.br/acervo/detalhe/373637
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
116p. : il.
dc.publisher.none.fl_str_mv [s.n.]
publisher.none.fl_str_mv [s.n.]
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
collection Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv sbubd@unicamp.br
_version_ 1809188949738913792