Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos

Detalhes bibliográficos
Autor(a) principal: Fugolin, Ana Paula Piovezan, 1987-
Data de Publicação: 2011
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
Texto Completo: https://hdl.handle.net/20.500.12733/1614686
Resumo: Orientador: Simonides Consani
id UNICAMP-30_c0feff6e0c862f9ee919bbaefa3b2842
oai_identifier_str oai::787560
network_acronym_str UNICAMP-30
network_name_str Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
repository_id_str
spelling Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitosInfluence of irradiance on Knoop hardness, degree of conversion and shrinkage of the different compositesResinas compostas - Propriedades mecânicasResinas compostas - Propriedades físicasResinas compostasComposite resinsMechanical propertiesPhysical propertiesOrientador: Simonides ConsaniDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de PiracicabaResumo: O objetivo neste estudo foi investigar a influência de diferentes irradiâncias e de energia emitida pelo fotoativador na dureza Knoop, grau de conversão e contração de polimerização de compósitos odontológicos com diferentes partículas de carga. Anéis de latão de 12 mm de diâmetro externo, 8 mm de diâmetro interno e 2 mm altura foram preenchidos com os compósitos Filtek Supreme XT® (ESPE 3M) e Charisma® (Heraeus Kulzer), ambos na cor A2. O aparelho utilizado foi o LED Bluephase G2 (Ivoclar-Vivadent), com tempo de fotoativação de 20 s e irradiância conforme o protocolo: grupos A e D- 300 mW/cm²; grupos B e E- 650 mW/cm² e grupos C e F- 1200mW/cm², sendo n = 5. Depois da polimerização, cada conjunto (matriz e amostra) foi submetido aos procedimentos de acabamento e polimento com lixas de carboneto de silício. A armazenagem foi em estufa a 37ºC por 24 horas, dispostos em recipiente a seco e no escuro. Após armazenagem, as superfícies de topo e base das amostras foram submetidas ao teste de dureza Knoop em durômetro, onde foram efetuadas 5 penetrações em cada região, com carga de 50 gf por 5 s. As amostras submetidas ao ensaio de dureza Knoop foram analisadas em microscopia eletrônica de varredura para verificar o nível de adaptação material-matriz. Por meio do programa UTHSCSA ImageTool foi mensurada a largura das fendas. Para avaliar o grau de conversão outras amostras foram confeccionadas, as quais foram avaliadas pelo FTIR com ATR. Os dados foram submetidos à ANOVA múltiplos fatores e teste de Tukey (5%). Os resultados mostraram que: A dureza Knoop do Filtek Supreme XT foi significativamente maior que do Charisma, independente do local e irradiância. Independente do material e local, as irradiâncias de 1200 mW/cm² e 650 mW/cm² mostraram valores de dureza estatisticamente similares, sendo ambas significativamente maiores aos de 300 mW/cm². Para Charisma houve diferença estatística significante entre topo e base nas irradiâncias de 300 mW/cm² e 650 mW/cm². No Filtek Supreme XT houve diferença estatística significante entre topo e base somente na irradiância de 300 mW/cm². Independente do local e irradiância, o grau de conversão do Charisma foi estatisticamente maior que do Filtek Supreme XT, exceto na irradiância de 650 mW/cm², onde os valores foram estatisticamente similares. No Charisma, a irradiância de 1200 mW/cm² proporcionou grau de conversão significativamente maior que 300 mW/cm² e 650 mW/cm², ambos similares entre si. No Filtek Supreme XT, a irradiância de 1200 mW/cm² proporcionou valor significativamente maior, 300 W/cm² menor e 650 mW/cm² valor intermediário. Independente da irradiância, para Filtek Supreme XT não houve diferença entre topo e base. Para Charisma, 300 mW/cm² e 650 mW/cm² apresentaram diferença estatística significante entre topo e base, sendo que em 1200 mW/cm² não houve diferença estatística significante. Independente da irradiância, a contração do Charisma foi significativamente maior que do Filtek Supreme XT. Independente do material, a contração promovida pelas irradiâncias foi similar. Os resultados deste estudo mostraram que a irradiância influenciou na dureza Knoop e no grau de conversão, não causando efeito na contração dos compósitos.Abstract: The aim of this study was to investigate the influence of both energy and power density (of different levels) emitted by light curing unit in the Knoop hardness, conversion degree and polymerization shrinkage of dental composites with different types of filler particles. Brass rings of 12mm outside diameter, 8mm internal diameter and 2mm height were filled with the composites Filtek Supreme XT® (3M ESPE) and Charisma (Heraeus Kulzer), both color A2. The light curing unit Bluephase G2 LED (Ivoclar-Vivadent) was used for 20s with irradiance according to the protocol; groups A and D ¿ 300 mW/cm², groups B and E ¿ 650 mW/cm² and groups C and F ¿ 1200 mW/cm². After polymerization, the sets (matrix and sample) were finished and polished with silicon carbide sandpaper and stored for 24 hours at 37°C in dark and dry container. After his period the specimens were evaluated for their hardness in an indenter, where top and bottom surfaces were submitted to five penetrations, with a load of 50gf for 5 s. Scanning electron microscopy (SEM) of these samples was carried out to check the gap between composite and matrix and the extent of crack were measured using the program UTHSCSA ImageTool. FTIR with ATR techniques assessed the degree of conversion of new samples. The data were analyzed by multiple factors ANOVA and Tukey test (p ? 0.05). In the results Filtek Supreme XT showed hardness values significantly higher than those of Charisma, regardless the location and the irradiance. At irradiances of 1200 mW/cm² and 650 mW/cm² showed hardness values statistically similar and significantly higher at 300 mW/cm², regardless the material and the location. Charisma showed a statistically significant difference between top and bottom in the irradiances 300 mW/cm² and 650 mW/cm². Filtek Supreme XT showed significant difference between top and bottom only in the irradiance of 300 mW/cm². The results for degree of conversion showed that, regardless the location and irradiance, Charisma had statistically higher values than Filtek Supreme XT, except for the irradiance of 650 mW/cm², where the values of the composites were statistically similar. At the power density of 1200 mW/cm², Charisma achieved values significantly higher than 650 mW/cm² and 300 mW/cm². At the power density of 1200 mW/cm² Filtek Supreme XT showed the highest conversion values, while at 300 mW/cm² showed the lowest values, and at 650 mW/cm² intermediate values were found. Regardless the irradiance, Filtek Supreme XT showed no difference between top and bottom. Charisma, at 300 mW/cm² and at 650 mW/cm² showed statistically significant difference between top and bottom, and at 1200 mW/cm² the difference was not statistically significant. Charisma showed significantly higher values of contraction than Filtek Supreme XT, regardless the irradiance. Regardless the material, no statistical difference was found for values of contraction for the evaluated irradiances. The findings of this study showed that the power density influenced the hardness and the degree of conversion, but not the contraction.MestradoMateriais DentáriosMestre em Materiais Dentários[s.n.]Consani, Simonides, 1939-Guiraldo, Ricardo DanilSinhoreti, Mário Alexandre CoelhoUniversidade Estadual de Campinas (UNICAMP). Faculdade de Odontologia de Piracicaba (FOP)Programa de Pós-Graduação em Materiais DentáriosUNIVERSIDADE ESTADUAL DE CAMPINASFugolin, Ana Paula Piovezan, 1987-2011info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdf106 f. : il.https://hdl.handle.net/20.500.12733/1614686FUGOLIN, Ana Paula Piovezan. Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos. 2011. 106 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba , Piracicaba, SP. Disponível em: https://hdl.handle.net/20.500.12733/1614686. Acesso em: 3 set. 2024.https://repositorio.unicamp.br/acervo/detalhe/787560porreponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPinfo:eu-repo/semantics/openAccess2017-02-18T06:11:25Zoai::787560Biblioteca Digital de Teses e DissertaçõesPUBhttp://repositorio.unicamp.br/oai/tese/oai.aspsbubd@unicamp.bropendoar:2017-02-18T06:11:25Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos
Influence of irradiance on Knoop hardness, degree of conversion and shrinkage of the different composites
title Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos
spellingShingle Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos
Fugolin, Ana Paula Piovezan, 1987-
Resinas compostas - Propriedades mecânicas
Resinas compostas - Propriedades físicas
Resinas compostas
Composite resins
Mechanical properties
Physical properties
title_short Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos
title_full Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos
title_fullStr Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos
title_full_unstemmed Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos
title_sort Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos
author Fugolin, Ana Paula Piovezan, 1987-
author_facet Fugolin, Ana Paula Piovezan, 1987-
author_role author
dc.contributor.none.fl_str_mv Consani, Simonides, 1939-
Guiraldo, Ricardo Danil
Sinhoreti, Mário Alexandre Coelho
Universidade Estadual de Campinas (UNICAMP). Faculdade de Odontologia de Piracicaba (FOP)
Programa de Pós-Graduação em Materiais Dentários
UNIVERSIDADE ESTADUAL DE CAMPINAS
dc.contributor.author.fl_str_mv Fugolin, Ana Paula Piovezan, 1987-
dc.subject.por.fl_str_mv Resinas compostas - Propriedades mecânicas
Resinas compostas - Propriedades físicas
Resinas compostas
Composite resins
Mechanical properties
Physical properties
topic Resinas compostas - Propriedades mecânicas
Resinas compostas - Propriedades físicas
Resinas compostas
Composite resins
Mechanical properties
Physical properties
description Orientador: Simonides Consani
publishDate 2011
dc.date.none.fl_str_mv 2011
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/20.500.12733/1614686
FUGOLIN, Ana Paula Piovezan. Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos. 2011. 106 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba , Piracicaba, SP. Disponível em: https://hdl.handle.net/20.500.12733/1614686. Acesso em: 3 set. 2024.
url https://hdl.handle.net/20.500.12733/1614686
identifier_str_mv FUGOLIN, Ana Paula Piovezan. Influência da irradiância na dureza Knoop, grau de conversão e contração de diferentes compósitos. 2011. 106 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba , Piracicaba, SP. Disponível em: https://hdl.handle.net/20.500.12733/1614686. Acesso em: 3 set. 2024.
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://repositorio.unicamp.br/acervo/detalhe/787560
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
106 f. : il.
dc.publisher.none.fl_str_mv [s.n.]
publisher.none.fl_str_mv [s.n.]
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
collection Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv sbubd@unicamp.br
_version_ 1822248891535327232