Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia

Detalhes bibliográficos
Autor(a) principal: Malthez, Anna Luiza Metidieri Cruz, 1985-
Data de Publicação: 2011
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
Texto Completo: https://hdl.handle.net/20.500.12733/1615907
Resumo: Orientadores: Vera Lúcia da Silveira Nantes Button, Marcio Aparecido Müller
id UNICAMP-30_d776464df514ef56a0ded69db7af05e3
oai_identifier_str oai::805370
network_acronym_str UNICAMP-30
network_name_str Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
repository_id_str
spelling Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapiaGEANT4 applicability and validation to Photons and Electrons in RadiotherapyMétodo de Monte CarloFótonsElétronsRadioterapiaMonte Carlo methodPhotonsElectronsRadiotherapyOrientadores: Vera Lúcia da Silveira Nantes Button, Marcio Aparecido MüllerDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de ComputaçãoResumo: Devido ao crescimento do uso de radiação ionizante em aplicações médicas, nas últimas décadas, os códigos para simulações de radiação interagindo com a matéria, baseados no Método de Monte Carlo, têm sido constantemente adaptados para aplicações em física médica. O método de Monte Carlo é um método estatístico de simulação numérica de problemas utilizando essencialmente uma sequência de números aleatórios. Atualmente, o método pode ser aplicado em simulações físicas, matemáticas e biológicas; o comportamento dos sistemas é descrito por amostragens aleatórias de funções de densidade de probabilidade e os acúmulos dos valores observados das amostragens produzem o resultado final da simulação. No caso de transporte de radiação, o valor esperado de grandezas de interesse, como, por exemplo, energia depositada ou dose em determinado meio ou volume de interesse simulado, pode ser estimado. Na maior parte das aplicações do método, o processo físico é simulado diretamente, necessitando somente da descrição matemática do processo físico, ou seja, da função densidade de probabilidade. Dentre os códigos mais utilizados para transporte de radiação, destacam-se: o EGS (Electron Gamma Shower); MCNP (Monte Carlo Neutron Photon Transport Code); ITS (Integrated Tiger Serie); PENELOPE (Penetration and Energy Loss of Positrons and Electrons) e o GEANT4 (Geometry and Tracking) disponibilizado pelo CERN (European Organization for Nuclear Research). O GEANT4 é um conjunto de ferramentas computacionais (toolkit) que utiliza programação orientada a objeto em C++, criado através de um projeto internacional e inicialmente utilizado para aplicações em física de altas energias; porém, atualmente é utilizado em áreas que compreendem desde astrofísica até física médica, com energias de 250 eV até 100 TeV. No toolkit do GEANT4 têm sido incorporados diversos processos físicos e partículas que permitem seu uso em física médica. Este código apresenta diversas vantagens em relação aos outros códigos, como, por exemplo, lidar com todos os tipos de partículas, geometrias complexas e estar em C++. Com o uso crescente dos códigos de Monte Carlo e das diversas aplicações do GEANT4 em física médica, publicadas recentemente, este código se apresentou como uma ferramenta promissora para aplicações na área de radioterapia, na qual vêm sendo utilizados diversos tipos de simulações. Considerando as vantagens deste código e suas aplicações em física médica, nesta dissertação de mestrado, foram desenvolvidas diversas simulações para verificar a aplicabilidade e validar o GEANT4 para aplicações em radioterapia. Por exemplo, foi estudada a dependência da energia depositada com parâmetros não-físicos do algoritmo de transporte de elétrons; o transporte de elétrons para energias de 1 a 20 MeV, que no G4 e em diversos outros códigos, apresentou problemas de grande relevância; e a influência do número de eventos nos resultados simulados. Também, foi avaliada a aplicação do G4 no transporte de radiação, através de simulações de elétrons e fótons emitidos por equipamentos e fontes usados em radioterapia, como acelerador linear e fontes de Co-60 e Ir-192, e através de cálculos de algumas grandezas, como dose, alcance e Stopping Power de elétrons monoenergéticos transportados em água. Os resultados em todas as simulações desenvolvidas apresentaram uma exatidão dentro de 2%, indicando que o GEANT4 pode ser utilizado, em simulações de fótons e elétrons, para aplicações em radioterapiaAbstract: Due to the increasing use of ionizing radiation in medical applications, in recent decades, the simulation codes for radiation interacting with matter, based on Monte Carlo Method, have been constantly adapted to applications in medical physics. TheMonte Carlo method is a statisticalmethod of numerical simulation of problems using essentially a sequence of random numbers. Currently, the method can be applied in physical, mathematical and biological simulations, the behavior of systems is described by random sampling of probability density functions and accumulation of the observed values of the samples producing the final result of the simulation. In the case of radiation transport, the expected value of quantities of interest such as, for example, dose or energy deposited in a medium or interest volume simulated, can be estimated. In most applications of the method, the physical process is simulated directly, requiring only the mathematical description of the physical process, ie the probability density function. Among the most commonly used codes for radiation transport are: the EGS (Electron Gamma Shower), MCNP (Monte Carlo Neutron Photon Transport Code), ITS (Integrated Tiger Series), PENELOPE (Penetration and Energy Loss of Electrons and Positrons) and Geant4 (Geometry and Tracking) released by CERN (European Organization for Nuclear Research). The GEANT4 is a set of computational tools (toolkit) that uses object-oriented programming in C++, created through an international project and initially used for applications in high energy physics, but is now used in areas that include from astrophysics to medical physics, with energies of 250 eV to 100 TeV. In the GEANT4 toolkit have been incorporated several physical processes and particles that allow its use in medical physics. This code has several advantages over other codes, for example, dealing with all types of particles and complex geometries and to be in C++. With the increasing use of Monte Carlo codes and the various applications of GEANT4 in medical physics, published recently, this code is presented as a promising tool for applications in radiotherapy, which have been used in various types of simulations. Considering the advantages of this code and its applications in medical physics in this dissertation, it was developed various simulations to verify the GEANT4 applicability and validation for radiotherapy applications. For example, it was study various aspects of implementation of the code, for example, the dependence of the energy deposited with non-physical parameters of the electrons transport algorithm, the transport of electrons to energies 1 to 20 MeV, in which GEANT4 and various other codes, presented problems of great relevance, and the influence of number of events in the simulated results. Also, it was evaluated the application of G4 in the transport of radiation through simulations of photons and electrons emitted by equipment and sources used in radiotherapy, as linear accelerator and sources of Co-60 and Ir-192, and by calculation of some quantities such as dose range and Stopping Power of monoenergetic electrons transported in water. The results in all simulations developed present a accuracy within 2%, indicating that Geant4 can be used, in simulations of photons and electrons, for applications in radiotherapyMestradoEngenharia BiomédicaMestre em Engenharia Elétrica[s.n.]Button, Vera Lúcia da Silveira Nantes, 1959-Müller, Márcio Aparecido, 1975-Biral, Antonio Renato PerissinotoBernal Rodriguez, Mario AntonioUniversidade Estadual de Campinas (UNICAMP). Faculdade de Engenharia Elétrica e de ComputaçãoPrograma de Pós-Graduação em Engenharia ElétricaUNIVERSIDADE ESTADUAL DE CAMPINASMalthez, Anna Luiza Metidieri Cruz, 1985-2011info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdf66 f. : il.https://hdl.handle.net/20.500.12733/1615907MALTHEZ, Anna Luiza Metidieri Cruz. Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia. 2011. 66 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1615907. Acesso em: 3 set. 2024.https://repositorio.unicamp.br/acervo/detalhe/805370porreponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPinfo:eu-repo/semantics/openAccess2017-02-18T06:21:17Zoai::805370Biblioteca Digital de Teses e DissertaçõesPUBhttp://repositorio.unicamp.br/oai/tese/oai.aspsbubd@unicamp.bropendoar:2017-02-18T06:21:17Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia
GEANT4 applicability and validation to Photons and Electrons in Radiotherapy
title Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia
spellingShingle Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia
Malthez, Anna Luiza Metidieri Cruz, 1985-
Método de Monte Carlo
Fótons
Elétrons
Radioterapia
Monte Carlo method
Photons
Electrons
Radiotherapy
title_short Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia
title_full Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia
title_fullStr Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia
title_full_unstemmed Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia
title_sort Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia
author Malthez, Anna Luiza Metidieri Cruz, 1985-
author_facet Malthez, Anna Luiza Metidieri Cruz, 1985-
author_role author
dc.contributor.none.fl_str_mv Button, Vera Lúcia da Silveira Nantes, 1959-
Müller, Márcio Aparecido, 1975-
Biral, Antonio Renato Perissinoto
Bernal Rodriguez, Mario Antonio
Universidade Estadual de Campinas (UNICAMP). Faculdade de Engenharia Elétrica e de Computação
Programa de Pós-Graduação em Engenharia Elétrica
UNIVERSIDADE ESTADUAL DE CAMPINAS
dc.contributor.author.fl_str_mv Malthez, Anna Luiza Metidieri Cruz, 1985-
dc.subject.por.fl_str_mv Método de Monte Carlo
Fótons
Elétrons
Radioterapia
Monte Carlo method
Photons
Electrons
Radiotherapy
topic Método de Monte Carlo
Fótons
Elétrons
Radioterapia
Monte Carlo method
Photons
Electrons
Radiotherapy
description Orientadores: Vera Lúcia da Silveira Nantes Button, Marcio Aparecido Müller
publishDate 2011
dc.date.none.fl_str_mv 2011
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/20.500.12733/1615907
MALTHEZ, Anna Luiza Metidieri Cruz. Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia. 2011. 66 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1615907. Acesso em: 3 set. 2024.
url https://hdl.handle.net/20.500.12733/1615907
identifier_str_mv MALTHEZ, Anna Luiza Metidieri Cruz. Aplicabilidade e validação do Geant4 para fótons e elétrons em radioterapia. 2011. 66 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação, Campinas, SP. Disponível em: https://hdl.handle.net/20.500.12733/1615907. Acesso em: 3 set. 2024.
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://repositorio.unicamp.br/acervo/detalhe/805370
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
66 f. : il.
dc.publisher.none.fl_str_mv [s.n.]
publisher.none.fl_str_mv [s.n.]
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
collection Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP)
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da Universidade Estadual de Campinas (UNICAMP) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv sbubd@unicamp.br
_version_ 1809189059426254848