Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements

Detalhes bibliográficos
Autor(a) principal: Jamel, Raghad S.
Data de Publicação: 2023
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian journal of oral sciences (Online)
DOI: 10.20396/bjos.v22i00.8671336
Texto Completo: https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8671336
Resumo: Aim: To investigate and compare the effects of different thicknesses of medium-translucency monolithic zirconia and light curing times on the polymerization of two types of dual-cured resin cement. Methods: A total of 200 cement specimens were prepared from TheraCem and RelyX U200 cement. The specimens were divided into 5 groups: Group I, without interposing zirconia; Group II, 0.50 mm thickness; Group III, 1.00 mm; Group IV, 1.50 mm; and Group V, 2.00 mm thickness. Each group was subdivided into (1) RelyX U200 and (2) TheraCem. Each subgroup was subdivided according to the light-curing time into (a) 20 s and (b) 40 s (n =5). The polymerization was tested using Fourier-transform infrared (FTIR) spectroscopy and a Vickers microhardness tester. The data were statistically analyzed using ANOVA, an independent sample t-test, and Tukey’s test at a significance level of 0.05. Results: The control group had the highest values of DC and VMH, followed by 0.50, 1.00, and 1.50 mm, respectively, while the 2.00 mm group showed the lowest values. The specimens irradiated for 40 s had greater DC and VMH than those irradiated for 20 s. RelyX U200 revealed higher values for both parameters compared to TheraCem cement. Conclusion: The polymerization of selfadhesive cement depends on the thickness of the monolithic zirconia, the light curing time, and the composition of the cement. The cement should be irradiated for a longer period than recommended to overcome the light attenuation of zirconia. TEGDMA-based self-adhesive cement showed a higher DC and VMH than BISGMA-based cement.
id UNICAMP-8_0e79faf49f59353b53875595fcf4f972
oai_identifier_str oai:ojs.periodicos.sbu.unicamp.br:article/8671336
network_acronym_str UNICAMP-8
network_name_str Brazilian journal of oral sciences (Online)
spelling Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements ZirconiumResin cementsPolymerizationAim: To investigate and compare the effects of different thicknesses of medium-translucency monolithic zirconia and light curing times on the polymerization of two types of dual-cured resin cement. Methods: A total of 200 cement specimens were prepared from TheraCem and RelyX U200 cement. The specimens were divided into 5 groups: Group I, without interposing zirconia; Group II, 0.50 mm thickness; Group III, 1.00 mm; Group IV, 1.50 mm; and Group V, 2.00 mm thickness. Each group was subdivided into (1) RelyX U200 and (2) TheraCem. Each subgroup was subdivided according to the light-curing time into (a) 20 s and (b) 40 s (n =5). The polymerization was tested using Fourier-transform infrared (FTIR) spectroscopy and a Vickers microhardness tester. The data were statistically analyzed using ANOVA, an independent sample t-test, and Tukey’s test at a significance level of 0.05. Results: The control group had the highest values of DC and VMH, followed by 0.50, 1.00, and 1.50 mm, respectively, while the 2.00 mm group showed the lowest values. The specimens irradiated for 40 s had greater DC and VMH than those irradiated for 20 s. RelyX U200 revealed higher values for both parameters compared to TheraCem cement. Conclusion: The polymerization of selfadhesive cement depends on the thickness of the monolithic zirconia, the light curing time, and the composition of the cement. The cement should be irradiated for a longer period than recommended to overcome the light attenuation of zirconia. TEGDMA-based self-adhesive cement showed a higher DC and VMH than BISGMA-based cement.Universidade Estadual de Campinas2023-07-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/otherapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/867133610.20396/bjos.v22i00.8671336Brazilian Journal of Oral Sciences; v. 22 (2023): Continuous Publication; e231336Brazilian Journal of Oral Sciences; Vol. 22 (2023): Continuous Publication; e2313361677-3225reponame:Brazilian journal of oral sciences (Online)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPenghttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8671336/32181Iraq; ContemporanyCopyright (c) 2023 Raghad S Jamelhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessJamel, Raghad S.2023-07-12T13:21:28Zoai:ojs.periodicos.sbu.unicamp.br:article/8671336Revistahttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/PUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/oaibrjorals@fop.unicamp.br||brjorals@fop.unicamp.br1677-32251677-3217opendoar:2023-07-12T13:21:28Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements
title Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements
spellingShingle Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements
Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements
Jamel, Raghad S.
Zirconium
Resin cements
Polymerization
Jamel, Raghad S.
Zirconium
Resin cements
Polymerization
title_short Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements
title_full Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements
title_fullStr Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements
Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements
title_full_unstemmed Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements
Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements
title_sort Influence of medium-translucency monolithic zirconia thicknesses and light-curing time on the polymerization of dual-cure resin cements
author Jamel, Raghad S.
author_facet Jamel, Raghad S.
Jamel, Raghad S.
author_role author
dc.contributor.author.fl_str_mv Jamel, Raghad S.
dc.subject.por.fl_str_mv Zirconium
Resin cements
Polymerization
topic Zirconium
Resin cements
Polymerization
description Aim: To investigate and compare the effects of different thicknesses of medium-translucency monolithic zirconia and light curing times on the polymerization of two types of dual-cured resin cement. Methods: A total of 200 cement specimens were prepared from TheraCem and RelyX U200 cement. The specimens were divided into 5 groups: Group I, without interposing zirconia; Group II, 0.50 mm thickness; Group III, 1.00 mm; Group IV, 1.50 mm; and Group V, 2.00 mm thickness. Each group was subdivided into (1) RelyX U200 and (2) TheraCem. Each subgroup was subdivided according to the light-curing time into (a) 20 s and (b) 40 s (n =5). The polymerization was tested using Fourier-transform infrared (FTIR) spectroscopy and a Vickers microhardness tester. The data were statistically analyzed using ANOVA, an independent sample t-test, and Tukey’s test at a significance level of 0.05. Results: The control group had the highest values of DC and VMH, followed by 0.50, 1.00, and 1.50 mm, respectively, while the 2.00 mm group showed the lowest values. The specimens irradiated for 40 s had greater DC and VMH than those irradiated for 20 s. RelyX U200 revealed higher values for both parameters compared to TheraCem cement. Conclusion: The polymerization of selfadhesive cement depends on the thickness of the monolithic zirconia, the light curing time, and the composition of the cement. The cement should be irradiated for a longer period than recommended to overcome the light attenuation of zirconia. TEGDMA-based self-adhesive cement showed a higher DC and VMH than BISGMA-based cement.
publishDate 2023
dc.date.none.fl_str_mv 2023-07-10
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/other
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8671336
10.20396/bjos.v22i00.8671336
url https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8671336
identifier_str_mv 10.20396/bjos.v22i00.8671336
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8671336/32181
dc.rights.driver.fl_str_mv Copyright (c) 2023 Raghad S Jamel
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2023 Raghad S Jamel
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv Iraq; Contemporany
dc.publisher.none.fl_str_mv Universidade Estadual de Campinas
publisher.none.fl_str_mv Universidade Estadual de Campinas
dc.source.none.fl_str_mv Brazilian Journal of Oral Sciences; v. 22 (2023): Continuous Publication; e231336
Brazilian Journal of Oral Sciences; Vol. 22 (2023): Continuous Publication; e231336
1677-3225
reponame:Brazilian journal of oral sciences (Online)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str Brazilian journal of oral sciences (Online)
collection Brazilian journal of oral sciences (Online)
repository.name.fl_str_mv Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv brjorals@fop.unicamp.br||brjorals@fop.unicamp.br
_version_ 1822179083652431872
dc.identifier.doi.none.fl_str_mv 10.20396/bjos.v22i00.8671336