Evaluation of characteristics of periodontal probes
Autor(a) principal: | |
---|---|
Data de Publicação: | 2024 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian journal of oral sciences (Online) |
Texto Completo: | https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8670401 |
Resumo: | Aim: This study aimed to evaluate the millimeter distances and active tip diameters of different periodontal probes. Methods: Two types of periodontal probes were analyzed (North Carolina (15-UNC) and PCP-12). Two manufacturers were selected for each probe type. Digital images of the probes were obtained and the distances were measured using a software program. The diameter of the active tip was measured using a digital caliper. Both variables were measured by two trained and calibrated examiners. The data were analyzed using the Bland-Altman method and two-way ANOVA with Tukey’s post-hoc test. Statistical significance was set at p<0.05. Results: A comparison of measurements between the 15UNC and PCP-12 probes showed a significant difference in all millimeter markings. The 15-UNC probe showed differences between the 3 and 12 mm markings. The PCP-12 probe only showed differences between the marks at the 12 mm mark. The 15-UNC probe had a similar active tip diameter between the two manufacturers. The PCP-12 probe showed a significant difference between the two manufacturers. Both types of probes had similar active tip diameters when compared by the two manufacturers. Conclusion: There was no standardization in relation to millimeter marks and tip diameters of the two types of periodontal probes produced by the two different manufacturers. The probe types exhibited little variability. |
id |
UNICAMP-8_13c2624eaadad6b880d1483859e5d513 |
---|---|
oai_identifier_str |
oai:ojs.periodicos.sbu.unicamp.br:article/8670401 |
network_acronym_str |
UNICAMP-8 |
network_name_str |
Brazilian journal of oral sciences (Online) |
repository_id_str |
|
spelling |
Evaluation of characteristics of periodontal probesPeriodontal indexPeriodontal diseasesPeriodonticsAim: This study aimed to evaluate the millimeter distances and active tip diameters of different periodontal probes. Methods: Two types of periodontal probes were analyzed (North Carolina (15-UNC) and PCP-12). Two manufacturers were selected for each probe type. Digital images of the probes were obtained and the distances were measured using a software program. The diameter of the active tip was measured using a digital caliper. Both variables were measured by two trained and calibrated examiners. The data were analyzed using the Bland-Altman method and two-way ANOVA with Tukey’s post-hoc test. Statistical significance was set at p<0.05. Results: A comparison of measurements between the 15UNC and PCP-12 probes showed a significant difference in all millimeter markings. The 15-UNC probe showed differences between the 3 and 12 mm markings. The PCP-12 probe only showed differences between the marks at the 12 mm mark. The 15-UNC probe had a similar active tip diameter between the two manufacturers. The PCP-12 probe showed a significant difference between the two manufacturers. Both types of probes had similar active tip diameters when compared by the two manufacturers. Conclusion: There was no standardization in relation to millimeter marks and tip diameters of the two types of periodontal probes produced by the two different manufacturers. The probe types exhibited little variability.Universidade Estadual de Campinas2024-03-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/otherapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/867040110.20396/bjos.v23i00.8670401Brazilian Journal of Oral Sciences; Vol. 23 (2024): Continuous Publication; e240401Brazilian Journal of Oral Sciences; v. 23 (2024): Continuous Publication; e2404011677-3225reponame:Brazilian journal of oral sciences (Online)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPenghttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8670401/33655Brazil; ContemporanyCopyright (c) 2024 Ana Cristina Kovalik, Alessandra Carla Sousa Girardi, Naiara Vendrami, Fabio André dos Santoshttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessKovalik, Ana CristinaGirardi, Alessandra Carla SousaVendrami, NaiaraSantos, Fabio André dos2024-03-11T19:15:27Zoai:ojs.periodicos.sbu.unicamp.br:article/8670401Revistahttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/PUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/oaibrjorals@fop.unicamp.br||brjorals@fop.unicamp.br1677-32251677-3217opendoar:2024-03-11T19:15:27Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)false |
dc.title.none.fl_str_mv |
Evaluation of characteristics of periodontal probes |
title |
Evaluation of characteristics of periodontal probes |
spellingShingle |
Evaluation of characteristics of periodontal probes Kovalik, Ana Cristina Periodontal index Periodontal diseases Periodontics |
title_short |
Evaluation of characteristics of periodontal probes |
title_full |
Evaluation of characteristics of periodontal probes |
title_fullStr |
Evaluation of characteristics of periodontal probes |
title_full_unstemmed |
Evaluation of characteristics of periodontal probes |
title_sort |
Evaluation of characteristics of periodontal probes |
author |
Kovalik, Ana Cristina |
author_facet |
Kovalik, Ana Cristina Girardi, Alessandra Carla Sousa Vendrami, Naiara Santos, Fabio André dos |
author_role |
author |
author2 |
Girardi, Alessandra Carla Sousa Vendrami, Naiara Santos, Fabio André dos |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Kovalik, Ana Cristina Girardi, Alessandra Carla Sousa Vendrami, Naiara Santos, Fabio André dos |
dc.subject.por.fl_str_mv |
Periodontal index Periodontal diseases Periodontics |
topic |
Periodontal index Periodontal diseases Periodontics |
description |
Aim: This study aimed to evaluate the millimeter distances and active tip diameters of different periodontal probes. Methods: Two types of periodontal probes were analyzed (North Carolina (15-UNC) and PCP-12). Two manufacturers were selected for each probe type. Digital images of the probes were obtained and the distances were measured using a software program. The diameter of the active tip was measured using a digital caliper. Both variables were measured by two trained and calibrated examiners. The data were analyzed using the Bland-Altman method and two-way ANOVA with Tukey’s post-hoc test. Statistical significance was set at p<0.05. Results: A comparison of measurements between the 15UNC and PCP-12 probes showed a significant difference in all millimeter markings. The 15-UNC probe showed differences between the 3 and 12 mm markings. The PCP-12 probe only showed differences between the marks at the 12 mm mark. The 15-UNC probe had a similar active tip diameter between the two manufacturers. The PCP-12 probe showed a significant difference between the two manufacturers. Both types of probes had similar active tip diameters when compared by the two manufacturers. Conclusion: There was no standardization in relation to millimeter marks and tip diameters of the two types of periodontal probes produced by the two different manufacturers. The probe types exhibited little variability. |
publishDate |
2024 |
dc.date.none.fl_str_mv |
2024-03-10 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/other |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8670401 10.20396/bjos.v23i00.8670401 |
url |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8670401 |
identifier_str_mv |
10.20396/bjos.v23i00.8670401 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8670401/33655 |
dc.rights.driver.fl_str_mv |
https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.coverage.none.fl_str_mv |
Brazil; Contemporany |
dc.publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
dc.source.none.fl_str_mv |
Brazilian Journal of Oral Sciences; Vol. 23 (2024): Continuous Publication; e240401 Brazilian Journal of Oral Sciences; v. 23 (2024): Continuous Publication; e240401 1677-3225 reponame:Brazilian journal of oral sciences (Online) instname:Universidade Estadual de Campinas (UNICAMP) instacron:UNICAMP |
instname_str |
Universidade Estadual de Campinas (UNICAMP) |
instacron_str |
UNICAMP |
institution |
UNICAMP |
reponame_str |
Brazilian journal of oral sciences (Online) |
collection |
Brazilian journal of oral sciences (Online) |
repository.name.fl_str_mv |
Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP) |
repository.mail.fl_str_mv |
brjorals@fop.unicamp.br||brjorals@fop.unicamp.br |
_version_ |
1800216397574307840 |