Simplified micrometric surface characterization of different implant surfaces available on the Brazilian market

Detalhes bibliográficos
Autor(a) principal: Carmo Filho, Luiz Carlos do
Data de Publicação: 2018
Outros Autores: Martins, Ana Paula Pinto, Bielemann, Amália Machado, Possebon, Anna Paula da Rosa, Faot, Fernanda
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian journal of oral sciences (Online)
Texto Completo: https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8652939
Resumo: Aim: This study characterized the implant surfaces available on the Brazilian market in terms of topography, chemical composition, and roughness. Methods: The following brands were selected according to their surfaces: Kopp (Ko), Signo Vinces (Sv), Neodent (Ne), Osseotite (Os) NanoTite (Nt), SIN (Si), Titanium Fix (Tf), conventional Straumann (Str), Active SLA (SLA). The morphological analysis and the alloy impurities and implant surface contaminants were analyzed by SEM-EDS. Surface roughness parameters and 3-D reconstructions were obtained by laser microscopy (20x). Two distinct areas were evaluated: i) the cervical portion (no surface treatment), and ii) the middle third (treated surface). Results: The characterization of the implant surfaces by SEM showed morphological differences between the thread geometries and surface morphology at 800x and 2000x magnification. The EDS elemental analysis showed a predominance of titanium (Ti) for all implants. The SLA surface showed only peaks of Ti while other implants brands showed traces of impurities and contaminants including Al, C, PR, F, Mg, Na, Ni, O, P, and SR. The implant surface roughness in the cervical portion did not exceed Ra 0.5–1.0 μm, constituting a minimally rough surface and obtaining acceptable standards for this region. Only Nt, Str, and SLA presented Ra above 2 μm in the middle third area showing a rough surface favorable for osseointegration. Conclusion: This study concluded that there is no established standard for morphology, chemical composition and implant surface roughness that allows a safe comparison between the available dental implant surfaces. National implant brands generally contain more impurities and surface contaminants than their international counterparts and were consequently more sensitive to the surface treatment techniques.
id UNICAMP-8_3147e2ba3ef3de7fbe36f633c46882f5
oai_identifier_str oai:ojs.periodicos.sbu.unicamp.br:article/8652939
network_acronym_str UNICAMP-8
network_name_str Brazilian journal of oral sciences (Online)
repository_id_str
spelling Simplified micrometric surface characterization of different implant surfaces available on the Brazilian marketDental ImplantsSurface PropertiesEnergy Dispersive X-ray Spectroscopy.Aim: This study characterized the implant surfaces available on the Brazilian market in terms of topography, chemical composition, and roughness. Methods: The following brands were selected according to their surfaces: Kopp (Ko), Signo Vinces (Sv), Neodent (Ne), Osseotite (Os) NanoTite (Nt), SIN (Si), Titanium Fix (Tf), conventional Straumann (Str), Active SLA (SLA). The morphological analysis and the alloy impurities and implant surface contaminants were analyzed by SEM-EDS. Surface roughness parameters and 3-D reconstructions were obtained by laser microscopy (20x). Two distinct areas were evaluated: i) the cervical portion (no surface treatment), and ii) the middle third (treated surface). Results: The characterization of the implant surfaces by SEM showed morphological differences between the thread geometries and surface morphology at 800x and 2000x magnification. The EDS elemental analysis showed a predominance of titanium (Ti) for all implants. The SLA surface showed only peaks of Ti while other implants brands showed traces of impurities and contaminants including Al, C, PR, F, Mg, Na, Ni, O, P, and SR. The implant surface roughness in the cervical portion did not exceed Ra 0.5–1.0 μm, constituting a minimally rough surface and obtaining acceptable standards for this region. Only Nt, Str, and SLA presented Ra above 2 μm in the middle third area showing a rough surface favorable for osseointegration. Conclusion: This study concluded that there is no established standard for morphology, chemical composition and implant surface roughness that allows a safe comparison between the available dental implant surfaces. National implant brands generally contain more impurities and surface contaminants than their international counterparts and were consequently more sensitive to the surface treatment techniques.Universidade Estadual de Campinas2018-07-16info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionOriginal articleapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/865293910.20396/bjos.v17i0.8652939Brazilian Journal of Oral Sciences; v. 17 (2018): Continuous Publication; e18371Brazilian Journal of Oral Sciences; Vol. 17 (2018): Continuous Publication; e183711677-3225reponame:Brazilian journal of oral sciences (Online)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPenghttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8652939/18443Carmo Filho, Luiz Carlos doMartins, Ana Paula PintoBielemann, Amália MachadoPossebon, Anna Paula da RosaFaot, Fernandainfo:eu-repo/semantics/openAccess2020-12-22T01:34:08Zoai:ojs.periodicos.sbu.unicamp.br:article/8652939Revistahttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/PUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/oaibrjorals@fop.unicamp.br||brjorals@fop.unicamp.br1677-32251677-3217opendoar:2020-12-22T01:34:08Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Simplified micrometric surface characterization of different implant surfaces available on the Brazilian market
title Simplified micrometric surface characterization of different implant surfaces available on the Brazilian market
spellingShingle Simplified micrometric surface characterization of different implant surfaces available on the Brazilian market
Carmo Filho, Luiz Carlos do
Dental Implants
Surface Properties
Energy Dispersive X-ray Spectroscopy.
title_short Simplified micrometric surface characterization of different implant surfaces available on the Brazilian market
title_full Simplified micrometric surface characterization of different implant surfaces available on the Brazilian market
title_fullStr Simplified micrometric surface characterization of different implant surfaces available on the Brazilian market
title_full_unstemmed Simplified micrometric surface characterization of different implant surfaces available on the Brazilian market
title_sort Simplified micrometric surface characterization of different implant surfaces available on the Brazilian market
author Carmo Filho, Luiz Carlos do
author_facet Carmo Filho, Luiz Carlos do
Martins, Ana Paula Pinto
Bielemann, Amália Machado
Possebon, Anna Paula da Rosa
Faot, Fernanda
author_role author
author2 Martins, Ana Paula Pinto
Bielemann, Amália Machado
Possebon, Anna Paula da Rosa
Faot, Fernanda
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Carmo Filho, Luiz Carlos do
Martins, Ana Paula Pinto
Bielemann, Amália Machado
Possebon, Anna Paula da Rosa
Faot, Fernanda
dc.subject.por.fl_str_mv Dental Implants
Surface Properties
Energy Dispersive X-ray Spectroscopy.
topic Dental Implants
Surface Properties
Energy Dispersive X-ray Spectroscopy.
description Aim: This study characterized the implant surfaces available on the Brazilian market in terms of topography, chemical composition, and roughness. Methods: The following brands were selected according to their surfaces: Kopp (Ko), Signo Vinces (Sv), Neodent (Ne), Osseotite (Os) NanoTite (Nt), SIN (Si), Titanium Fix (Tf), conventional Straumann (Str), Active SLA (SLA). The morphological analysis and the alloy impurities and implant surface contaminants were analyzed by SEM-EDS. Surface roughness parameters and 3-D reconstructions were obtained by laser microscopy (20x). Two distinct areas were evaluated: i) the cervical portion (no surface treatment), and ii) the middle third (treated surface). Results: The characterization of the implant surfaces by SEM showed morphological differences between the thread geometries and surface morphology at 800x and 2000x magnification. The EDS elemental analysis showed a predominance of titanium (Ti) for all implants. The SLA surface showed only peaks of Ti while other implants brands showed traces of impurities and contaminants including Al, C, PR, F, Mg, Na, Ni, O, P, and SR. The implant surface roughness in the cervical portion did not exceed Ra 0.5–1.0 μm, constituting a minimally rough surface and obtaining acceptable standards for this region. Only Nt, Str, and SLA presented Ra above 2 μm in the middle third area showing a rough surface favorable for osseointegration. Conclusion: This study concluded that there is no established standard for morphology, chemical composition and implant surface roughness that allows a safe comparison between the available dental implant surfaces. National implant brands generally contain more impurities and surface contaminants than their international counterparts and were consequently more sensitive to the surface treatment techniques.
publishDate 2018
dc.date.none.fl_str_mv 2018-07-16
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Original article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8652939
10.20396/bjos.v17i0.8652939
url https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8652939
identifier_str_mv 10.20396/bjos.v17i0.8652939
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8652939/18443
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual de Campinas
publisher.none.fl_str_mv Universidade Estadual de Campinas
dc.source.none.fl_str_mv Brazilian Journal of Oral Sciences; v. 17 (2018): Continuous Publication; e18371
Brazilian Journal of Oral Sciences; Vol. 17 (2018): Continuous Publication; e18371
1677-3225
reponame:Brazilian journal of oral sciences (Online)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str Brazilian journal of oral sciences (Online)
collection Brazilian journal of oral sciences (Online)
repository.name.fl_str_mv Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv brjorals@fop.unicamp.br||brjorals@fop.unicamp.br
_version_ 1800216402290802688