Influence of zinc oxide-eugenol temporary cement on bond strength of an all-in-one adhesive system to bovine dentin
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian journal of oral sciences (Online) |
Texto Completo: | https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8643005 |
Resumo: | The objective of this study was to evaluate the influence of temporary zinc oxide-eugenol cements (ZOEs) on the microtensile bond strength (ìTBS) of an all-in-one adhesive system to dentin. Buccal dentin surface of fifteen bovine incisors were exposed and polished with 600-grit SiC paper. Next, three groups were formed: Group 1 (G1), in which the dentin surface was covered with ZOE (TempCem); Group 2 (G2), in which the dentin surface was covered with temporary cement composed of zinc oxide and an aliphatic acid replacing eugenol (TempCem NE); Group 3 (G3) - no temporary cement was used. Each group was individually stored in distilled water at 37° C for 7 days, whereupon temporary cements were mechanically removed. All groups underwent the adhesive protocol with a simplified self-etching adhesive (One-UP Bond F). Four sticks per tooth were obtained, resulting in 20 sticks per group with a cross-sectional area of 0.5 mm2 . The ìTBS test was performed with a crosshead speed of 1mm/min. The failure pattern was analyzed by SEM. The data were submitted to one-way ANOVA, at p<0.05. The mean values were 44.67 MPa for G3, followed by 41.35 MPa for G2 and 39.33 MPa for G1. There was no significant statistical difference between groups. The failure pattern was almost mixed with the adhesive layer and dentin. The eugenol presented in TempCem did not influence the ìTBS test when a simplified selfetching adhesive system was used |
id |
UNICAMP-8_4bf7e11d77a01214052c9c9a5cf4d535 |
---|---|
oai_identifier_str |
oai:ojs.periodicos.sbu.unicamp.br:article/8643005 |
network_acronym_str |
UNICAMP-8 |
network_name_str |
Brazilian journal of oral sciences (Online) |
repository_id_str |
|
spelling |
Influence of zinc oxide-eugenol temporary cement on bond strength of an all-in-one adhesive system to bovine dentinZinc oxide-eugenol. Dentin. Microtensile bond strength. Self-etching. Adhesive systemOdontologiaThe objective of this study was to evaluate the influence of temporary zinc oxide-eugenol cements (ZOEs) on the microtensile bond strength (ìTBS) of an all-in-one adhesive system to dentin. Buccal dentin surface of fifteen bovine incisors were exposed and polished with 600-grit SiC paper. Next, three groups were formed: Group 1 (G1), in which the dentin surface was covered with ZOE (TempCem); Group 2 (G2), in which the dentin surface was covered with temporary cement composed of zinc oxide and an aliphatic acid replacing eugenol (TempCem NE); Group 3 (G3) - no temporary cement was used. Each group was individually stored in distilled water at 37° C for 7 days, whereupon temporary cements were mechanically removed. All groups underwent the adhesive protocol with a simplified self-etching adhesive (One-UP Bond F). Four sticks per tooth were obtained, resulting in 20 sticks per group with a cross-sectional area of 0.5 mm2 . The ìTBS test was performed with a crosshead speed of 1mm/min. The failure pattern was analyzed by SEM. The data were submitted to one-way ANOVA, at p<0.05. The mean values were 44.67 MPa for G3, followed by 41.35 MPa for G2 and 39.33 MPa for G1. There was no significant statistical difference between groups. The failure pattern was almost mixed with the adhesive layer and dentin. The eugenol presented in TempCem did not influence the ìTBS test when a simplified selfetching adhesive system was usedUniversidade Estadual de Campinas2016-01-22info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/864300510.20396/bjos.v6i23.8643005Brazilian Journal of Oral Sciences; v. 6 n. 23 (2007): Oct./Dec; 1423-1427Brazilian Journal of Oral Sciences; Vol. 6 No. 23 (2007): Oct./Dec; 1423-14271677-3225reponame:Brazilian journal of oral sciences (Online)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPenghttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8643005/10560Schwartzer, EduardoCollares, Fabrício MezzomoOgliari, Fabrício AuloLeitune, Vicente Castelo BrancoSamuel, Susana Maria Wernerinfo:eu-repo/semantics/openAccess2016-02-25T09:25:30Zoai:ojs.periodicos.sbu.unicamp.br:article/8643005Revistahttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/PUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/oaibrjorals@fop.unicamp.br||brjorals@fop.unicamp.br1677-32251677-3217opendoar:2016-02-25T09:25:30Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)false |
dc.title.none.fl_str_mv |
Influence of zinc oxide-eugenol temporary cement on bond strength of an all-in-one adhesive system to bovine dentin |
title |
Influence of zinc oxide-eugenol temporary cement on bond strength of an all-in-one adhesive system to bovine dentin |
spellingShingle |
Influence of zinc oxide-eugenol temporary cement on bond strength of an all-in-one adhesive system to bovine dentin Schwartzer, Eduardo Zinc oxide-eugenol. Dentin. Microtensile bond strength. Self-etching. Adhesive system Odontologia |
title_short |
Influence of zinc oxide-eugenol temporary cement on bond strength of an all-in-one adhesive system to bovine dentin |
title_full |
Influence of zinc oxide-eugenol temporary cement on bond strength of an all-in-one adhesive system to bovine dentin |
title_fullStr |
Influence of zinc oxide-eugenol temporary cement on bond strength of an all-in-one adhesive system to bovine dentin |
title_full_unstemmed |
Influence of zinc oxide-eugenol temporary cement on bond strength of an all-in-one adhesive system to bovine dentin |
title_sort |
Influence of zinc oxide-eugenol temporary cement on bond strength of an all-in-one adhesive system to bovine dentin |
author |
Schwartzer, Eduardo |
author_facet |
Schwartzer, Eduardo Collares, Fabrício Mezzomo Ogliari, Fabrício Aulo Leitune, Vicente Castelo Branco Samuel, Susana Maria Werner |
author_role |
author |
author2 |
Collares, Fabrício Mezzomo Ogliari, Fabrício Aulo Leitune, Vicente Castelo Branco Samuel, Susana Maria Werner |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Schwartzer, Eduardo Collares, Fabrício Mezzomo Ogliari, Fabrício Aulo Leitune, Vicente Castelo Branco Samuel, Susana Maria Werner |
dc.subject.por.fl_str_mv |
Zinc oxide-eugenol. Dentin. Microtensile bond strength. Self-etching. Adhesive system Odontologia |
topic |
Zinc oxide-eugenol. Dentin. Microtensile bond strength. Self-etching. Adhesive system Odontologia |
description |
The objective of this study was to evaluate the influence of temporary zinc oxide-eugenol cements (ZOEs) on the microtensile bond strength (ìTBS) of an all-in-one adhesive system to dentin. Buccal dentin surface of fifteen bovine incisors were exposed and polished with 600-grit SiC paper. Next, three groups were formed: Group 1 (G1), in which the dentin surface was covered with ZOE (TempCem); Group 2 (G2), in which the dentin surface was covered with temporary cement composed of zinc oxide and an aliphatic acid replacing eugenol (TempCem NE); Group 3 (G3) - no temporary cement was used. Each group was individually stored in distilled water at 37° C for 7 days, whereupon temporary cements were mechanically removed. All groups underwent the adhesive protocol with a simplified self-etching adhesive (One-UP Bond F). Four sticks per tooth were obtained, resulting in 20 sticks per group with a cross-sectional area of 0.5 mm2 . The ìTBS test was performed with a crosshead speed of 1mm/min. The failure pattern was analyzed by SEM. The data were submitted to one-way ANOVA, at p<0.05. The mean values were 44.67 MPa for G3, followed by 41.35 MPa for G2 and 39.33 MPa for G1. There was no significant statistical difference between groups. The failure pattern was almost mixed with the adhesive layer and dentin. The eugenol presented in TempCem did not influence the ìTBS test when a simplified selfetching adhesive system was used |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-01-22 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8643005 10.20396/bjos.v6i23.8643005 |
url |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8643005 |
identifier_str_mv |
10.20396/bjos.v6i23.8643005 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8643005/10560 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
dc.source.none.fl_str_mv |
Brazilian Journal of Oral Sciences; v. 6 n. 23 (2007): Oct./Dec; 1423-1427 Brazilian Journal of Oral Sciences; Vol. 6 No. 23 (2007): Oct./Dec; 1423-1427 1677-3225 reponame:Brazilian journal of oral sciences (Online) instname:Universidade Estadual de Campinas (UNICAMP) instacron:UNICAMP |
instname_str |
Universidade Estadual de Campinas (UNICAMP) |
instacron_str |
UNICAMP |
institution |
UNICAMP |
reponame_str |
Brazilian journal of oral sciences (Online) |
collection |
Brazilian journal of oral sciences (Online) |
repository.name.fl_str_mv |
Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP) |
repository.mail.fl_str_mv |
brjorals@fop.unicamp.br||brjorals@fop.unicamp.br |
_version_ |
1800216401207623680 |