Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian journal of oral sciences (Online) |
DOI: | 10.20396/bjos.v9i4.8641735 |
Texto Completo: | https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641735 |
Resumo: | Aim: To evaluate the selective acid etching of enamel and dentin on microtensile bond strength (µTBS) of a self-adhesive resin cement. Methods: Forty-eight bovine teeth were selected and had the buccal surface ground to obtain a flat dentin (n=24) or enamel (n=24) surface. Z250 composite resin blocks (4 x 3 x 8 mm) were prepared for cementation at enamel and dentin. Each substrate received three experimental resin cementation strategies: 1) 37% phosphoric acid etching before the application of RelyX Unicem; 2) application of RelyX Unicem alone; 3) RelyX ARC as a control. Samples were light-cured using a halogen light (Optilux 501, 700mW/cm2 ), for 40 s. Hourglass-shaped specimens were obtained and submitted to a tensile strength at a crosshead speed of 0.5 mm/min in a universal testing machine. For statistical analysis, data were submitted to ANOVA and Tukey’s test at a pre-set alpha (á=0.05). Results: RelyX Unicem showed similar bond strength value (16.5 MPa) when compared to the pretreatment with acid etching (11.9 Mpa) and to the conventional resin cement (18.1 MPa) for enamel. All luting strategies presented similar dentin bond strength, but significantly lower than enamel bond strength. Conclusions: Acid etching prior to RelyX Unicem application did not improve microtensile bond strength for enamel and dentin. |
id |
UNICAMP-8_91841010ee58b5e73b933753c0510264 |
---|---|
oai_identifier_str |
oai:ojs.periodicos.sbu.unicamp.br:article/8641735 |
network_acronym_str |
UNICAMP-8 |
network_name_str |
Brazilian journal of oral sciences (Online) |
spelling |
Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentinResin cementBond strengthDental enamelDentinDental acid etchingOdontologyAim: To evaluate the selective acid etching of enamel and dentin on microtensile bond strength (µTBS) of a self-adhesive resin cement. Methods: Forty-eight bovine teeth were selected and had the buccal surface ground to obtain a flat dentin (n=24) or enamel (n=24) surface. Z250 composite resin blocks (4 x 3 x 8 mm) were prepared for cementation at enamel and dentin. Each substrate received three experimental resin cementation strategies: 1) 37% phosphoric acid etching before the application of RelyX Unicem; 2) application of RelyX Unicem alone; 3) RelyX ARC as a control. Samples were light-cured using a halogen light (Optilux 501, 700mW/cm2 ), for 40 s. Hourglass-shaped specimens were obtained and submitted to a tensile strength at a crosshead speed of 0.5 mm/min in a universal testing machine. For statistical analysis, data were submitted to ANOVA and Tukey’s test at a pre-set alpha (á=0.05). Results: RelyX Unicem showed similar bond strength value (16.5 MPa) when compared to the pretreatment with acid etching (11.9 Mpa) and to the conventional resin cement (18.1 MPa) for enamel. All luting strategies presented similar dentin bond strength, but significantly lower than enamel bond strength. Conclusions: Acid etching prior to RelyX Unicem application did not improve microtensile bond strength for enamel and dentin.Universidade Estadual de Campinas2015-11-16info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/864173510.20396/bjos.v9i4.8641735Brazilian Journal of Oral Sciences; v. 9 n. 4 (2010): Oct./Dec.; 455-458Brazilian Journal of Oral Sciences; Vol. 9 No. 4 (2010): Oct./Dec.; 455-4581677-3225reponame:Brazilian journal of oral sciences (Online)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPenghttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641735/9233Prieto, Lúcia TrazziAraújo, Cíntia Tereza PimentaHumel, Maria Malerba ColombiSouza-Junior, Eduardo JoséDias, Carlos Tadeu dos Santosinfo:eu-repo/semantics/openAccess2016-02-25T09:12:14Zoai:ojs.periodicos.sbu.unicamp.br:article/8641735Revistahttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/PUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/oaibrjorals@fop.unicamp.br||brjorals@fop.unicamp.br1677-32251677-3217opendoar:2016-02-25T09:12:14Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)false |
dc.title.none.fl_str_mv |
Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin |
title |
Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin |
spellingShingle |
Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin Prieto, Lúcia Trazzi Resin cement Bond strength Dental enamel Dentin Dental acid etching Odontology Prieto, Lúcia Trazzi Resin cement Bond strength Dental enamel Dentin Dental acid etching Odontology |
title_short |
Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin |
title_full |
Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin |
title_fullStr |
Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin |
title_full_unstemmed |
Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin |
title_sort |
Influence of selective acid etching on microtensile bond strength of a self-adhesive resin cement to enamel and dentin |
author |
Prieto, Lúcia Trazzi |
author_facet |
Prieto, Lúcia Trazzi Prieto, Lúcia Trazzi Araújo, Cíntia Tereza Pimenta Humel, Maria Malerba Colombi Souza-Junior, Eduardo José Dias, Carlos Tadeu dos Santos Araújo, Cíntia Tereza Pimenta Humel, Maria Malerba Colombi Souza-Junior, Eduardo José Dias, Carlos Tadeu dos Santos |
author_role |
author |
author2 |
Araújo, Cíntia Tereza Pimenta Humel, Maria Malerba Colombi Souza-Junior, Eduardo José Dias, Carlos Tadeu dos Santos |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Prieto, Lúcia Trazzi Araújo, Cíntia Tereza Pimenta Humel, Maria Malerba Colombi Souza-Junior, Eduardo José Dias, Carlos Tadeu dos Santos |
dc.subject.por.fl_str_mv |
Resin cement Bond strength Dental enamel Dentin Dental acid etching Odontology |
topic |
Resin cement Bond strength Dental enamel Dentin Dental acid etching Odontology |
description |
Aim: To evaluate the selective acid etching of enamel and dentin on microtensile bond strength (µTBS) of a self-adhesive resin cement. Methods: Forty-eight bovine teeth were selected and had the buccal surface ground to obtain a flat dentin (n=24) or enamel (n=24) surface. Z250 composite resin blocks (4 x 3 x 8 mm) were prepared for cementation at enamel and dentin. Each substrate received three experimental resin cementation strategies: 1) 37% phosphoric acid etching before the application of RelyX Unicem; 2) application of RelyX Unicem alone; 3) RelyX ARC as a control. Samples were light-cured using a halogen light (Optilux 501, 700mW/cm2 ), for 40 s. Hourglass-shaped specimens were obtained and submitted to a tensile strength at a crosshead speed of 0.5 mm/min in a universal testing machine. For statistical analysis, data were submitted to ANOVA and Tukey’s test at a pre-set alpha (á=0.05). Results: RelyX Unicem showed similar bond strength value (16.5 MPa) when compared to the pretreatment with acid etching (11.9 Mpa) and to the conventional resin cement (18.1 MPa) for enamel. All luting strategies presented similar dentin bond strength, but significantly lower than enamel bond strength. Conclusions: Acid etching prior to RelyX Unicem application did not improve microtensile bond strength for enamel and dentin. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-11-16 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641735 10.20396/bjos.v9i4.8641735 |
url |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641735 |
identifier_str_mv |
10.20396/bjos.v9i4.8641735 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641735/9233 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
publisher.none.fl_str_mv |
Universidade Estadual de Campinas |
dc.source.none.fl_str_mv |
Brazilian Journal of Oral Sciences; v. 9 n. 4 (2010): Oct./Dec.; 455-458 Brazilian Journal of Oral Sciences; Vol. 9 No. 4 (2010): Oct./Dec.; 455-458 1677-3225 reponame:Brazilian journal of oral sciences (Online) instname:Universidade Estadual de Campinas (UNICAMP) instacron:UNICAMP |
instname_str |
Universidade Estadual de Campinas (UNICAMP) |
instacron_str |
UNICAMP |
institution |
UNICAMP |
reponame_str |
Brazilian journal of oral sciences (Online) |
collection |
Brazilian journal of oral sciences (Online) |
repository.name.fl_str_mv |
Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP) |
repository.mail.fl_str_mv |
brjorals@fop.unicamp.br||brjorals@fop.unicamp.br |
_version_ |
1822181788566421504 |
dc.identifier.doi.none.fl_str_mv |
10.20396/bjos.v9i4.8641735 |