Double-blind study for evaluation of complete dentures made by two techniques with and without face-bow.

Detalhes bibliográficos
Autor(a) principal: Nascimento, Daniela Fernandes Figueira
Data de Publicação: 2015
Outros Autores: Patto, Renata Beatriz Luz, Marchini, Leonardo, Cunha, Vicente de Paula Prisco
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian journal of oral sciences (Online)
Texto Completo: https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641745
Resumo: The aim of this article was to compare complete dentures made by two techniques: with and without face-bow. Five edentulous subjects were selected and each one received two pairs of complete dentures. Dentures were made from duplicated casts and each one followed different techniques. One technique used face-bow and artificial teeth. Teeth were set using individualized wax ridges as guides. The other technique used an articulator, which avoids face-bow and teeth were set by the cast-analysis method. The number of occlusal contacts in centric relation and excursive movements were registered, as well as the opinion of patients regarding denture bearing during oral functions. Both groups presented balanced dentures, but the technique that avoids face-bow presented better results regarding to esthetics, comfort and stability. Balanced occlusion was provided even without face-bow and could be an alternative to obtain adequate complete dentures.
id UNICAMP-8_a1787da01bf28e8ed1cde2a3b683fb7a
oai_identifier_str oai:ojs.periodicos.sbu.unicamp.br:article/8641745
network_acronym_str UNICAMP-8
network_name_str Brazilian journal of oral sciences (Online)
repository_id_str
spelling Double-blind study for evaluation of complete dentures made by two techniques with and without face-bow.Complete dentures. Articulators. OcclusionOdontologiaThe aim of this article was to compare complete dentures made by two techniques: with and without face-bow. Five edentulous subjects were selected and each one received two pairs of complete dentures. Dentures were made from duplicated casts and each one followed different techniques. One technique used face-bow and artificial teeth. Teeth were set using individualized wax ridges as guides. The other technique used an articulator, which avoids face-bow and teeth were set by the cast-analysis method. The number of occlusal contacts in centric relation and excursive movements were registered, as well as the opinion of patients regarding denture bearing during oral functions. Both groups presented balanced dentures, but the technique that avoids face-bow presented better results regarding to esthetics, comfort and stability. Balanced occlusion was provided even without face-bow and could be an alternative to obtain adequate complete dentures.Universidade Estadual de Campinas2015-11-16info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/864174510.20396/bjos.v3i9.8641745Brazilian Journal of Oral Sciences; v. 3 n. 9 (2004): Apr./Jun.; 439-445Brazilian Journal of Oral Sciences; Vol. 3 No. 9 (2004): Apr./Jun.; 439-4451677-3225reponame:Brazilian journal of oral sciences (Online)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPenghttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641745/9244Nascimento, Daniela Fernandes FigueiraPatto, Renata Beatriz LuzMarchini, LeonardoCunha, Vicente de Paula Priscoinfo:eu-repo/semantics/openAccess2016-02-25T09:29:28Zoai:ojs.periodicos.sbu.unicamp.br:article/8641745Revistahttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/PUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/oaibrjorals@fop.unicamp.br||brjorals@fop.unicamp.br1677-32251677-3217opendoar:2016-02-25T09:29:28Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Double-blind study for evaluation of complete dentures made by two techniques with and without face-bow.
title Double-blind study for evaluation of complete dentures made by two techniques with and without face-bow.
spellingShingle Double-blind study for evaluation of complete dentures made by two techniques with and without face-bow.
Nascimento, Daniela Fernandes Figueira
Complete dentures. Articulators. Occlusion
Odontologia
title_short Double-blind study for evaluation of complete dentures made by two techniques with and without face-bow.
title_full Double-blind study for evaluation of complete dentures made by two techniques with and without face-bow.
title_fullStr Double-blind study for evaluation of complete dentures made by two techniques with and without face-bow.
title_full_unstemmed Double-blind study for evaluation of complete dentures made by two techniques with and without face-bow.
title_sort Double-blind study for evaluation of complete dentures made by two techniques with and without face-bow.
author Nascimento, Daniela Fernandes Figueira
author_facet Nascimento, Daniela Fernandes Figueira
Patto, Renata Beatriz Luz
Marchini, Leonardo
Cunha, Vicente de Paula Prisco
author_role author
author2 Patto, Renata Beatriz Luz
Marchini, Leonardo
Cunha, Vicente de Paula Prisco
author2_role author
author
author
dc.contributor.author.fl_str_mv Nascimento, Daniela Fernandes Figueira
Patto, Renata Beatriz Luz
Marchini, Leonardo
Cunha, Vicente de Paula Prisco
dc.subject.por.fl_str_mv Complete dentures. Articulators. Occlusion
Odontologia
topic Complete dentures. Articulators. Occlusion
Odontologia
description The aim of this article was to compare complete dentures made by two techniques: with and without face-bow. Five edentulous subjects were selected and each one received two pairs of complete dentures. Dentures were made from duplicated casts and each one followed different techniques. One technique used face-bow and artificial teeth. Teeth were set using individualized wax ridges as guides. The other technique used an articulator, which avoids face-bow and teeth were set by the cast-analysis method. The number of occlusal contacts in centric relation and excursive movements were registered, as well as the opinion of patients regarding denture bearing during oral functions. Both groups presented balanced dentures, but the technique that avoids face-bow presented better results regarding to esthetics, comfort and stability. Balanced occlusion was provided even without face-bow and could be an alternative to obtain adequate complete dentures.
publishDate 2015
dc.date.none.fl_str_mv 2015-11-16
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641745
10.20396/bjos.v3i9.8641745
url https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641745
identifier_str_mv 10.20396/bjos.v3i9.8641745
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8641745/9244
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Estadual de Campinas
publisher.none.fl_str_mv Universidade Estadual de Campinas
dc.source.none.fl_str_mv Brazilian Journal of Oral Sciences; v. 3 n. 9 (2004): Apr./Jun.; 439-445
Brazilian Journal of Oral Sciences; Vol. 3 No. 9 (2004): Apr./Jun.; 439-445
1677-3225
reponame:Brazilian journal of oral sciences (Online)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str Brazilian journal of oral sciences (Online)
collection Brazilian journal of oral sciences (Online)
repository.name.fl_str_mv Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv brjorals@fop.unicamp.br||brjorals@fop.unicamp.br
_version_ 1800216399929409536