Effect of dentin contamination and cleaning on the bond strength of resin-modified glass ionomer cement

Detalhes bibliográficos
Autor(a) principal: Almeida, Morganna Borges de
Data de Publicação: 2021
Outros Autores: Santos, Paulo Henrique dos, Esteves, Lara Maria Bueno, Silva, Lívia Maria Alves Valentim da, Gallinari, Marjorie de Oliveira, Fagundes, Ticiane Cestari, Antonnaccio, Giulia Bessa de Mello, Briso, André Luiz Fraga
Tipo de documento: Artigo
Idioma: por
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/15983
Resumo: This study aimed to evaluate the effect of dentin contamination and cleaning techniques on the bond strength of resin-modified glass ionomer (RMGI)/dentin interfaces.168 bovine teeth were selected and divided into twelve groups (n = 14), according to the contaminating agent (S - no contamination; Sa - saliva; Sg - blood; H - hemostatic) and cleaning technique (S - without cleaning; A - air and water spray; P - polyacrylic acid reconditioning 26%). All specimens were restored with Riva Light Cure (SDI) ionomeric material, sectioned (1.0 × 1.0 mm toothpicks), and subjected to the microtensile bond strength test and a thermocycling regimen (CT).  In the immediate analysis, all contaminated groups without cleaning had the following adhesion values when compared with the control group. After thermocycling, in the groups without cleaning only the hemostatic was identified to the control. The Sa groups maintained the immediate analysis standard, while the Sg groups were similar to the control, regardless of the time analyzed. Groups H were similar to each other. In conclusion, the contaminants tested impaired the immediate adhesion of the ionomeric material to dentin. Substrate reconditioning was effective in specimens contaminated with saliva and hemostatic agent. However, bond strength values reduced after aging.
id UNIFEI_0a9309ed0a355faa4911bd7da356e23d
oai_identifier_str oai:ojs.pkp.sfu.ca:article/15983
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Effect of dentin contamination and cleaning on the bond strength of resin-modified glass ionomer cementEfecto de la contaminación y la limpieza de la dentina sobre la fuerza de unión del cemento de ionómero de vidrio modificado con resinaEfeito da contaminação e limpeza da dentina na resistência de união do cimento de ionômero de vidro modificado por resinaContaminaçãoOdontologiaCimentos de ionômero de vidroResistência à tração.ContaminationDentistryGlass ionomer cementsTensile strength. ContaminaciónOdontologíaCementos de ionómero de vidrioFuerza de tensión.This study aimed to evaluate the effect of dentin contamination and cleaning techniques on the bond strength of resin-modified glass ionomer (RMGI)/dentin interfaces.168 bovine teeth were selected and divided into twelve groups (n = 14), according to the contaminating agent (S - no contamination; Sa - saliva; Sg - blood; H - hemostatic) and cleaning technique (S - without cleaning; A - air and water spray; P - polyacrylic acid reconditioning 26%). All specimens were restored with Riva Light Cure (SDI) ionomeric material, sectioned (1.0 × 1.0 mm toothpicks), and subjected to the microtensile bond strength test and a thermocycling regimen (CT).  In the immediate analysis, all contaminated groups without cleaning had the following adhesion values when compared with the control group. After thermocycling, in the groups without cleaning only the hemostatic was identified to the control. The Sa groups maintained the immediate analysis standard, while the Sg groups were similar to the control, regardless of the time analyzed. Groups H were similar to each other. In conclusion, the contaminants tested impaired the immediate adhesion of the ionomeric material to dentin. Substrate reconditioning was effective in specimens contaminated with saliva and hemostatic agent. However, bond strength values reduced after aging.Este estudio tuvo como objetivo evaluar el efecto de la contaminación de la dentina y las técnicas de limpieza sobre la fuerza de unión de las interfaces de ionómero de vidrio modificado con resina (RMGI) / dentina.168 dientes bovinos fueron seleccionados y divididos en doce grupos (n = 14), de acuerdo con la contaminación agente (S - sin contaminación; Sa - saliva; Sg - sangre; H - hemostático) y técnica de limpieza (S - sin limpiar; A - spray de aire y agua; P - reacondicionamiento de ácido poliacrílico 26%). Todas las muestras se restauraron con material ionomérico Riva Light Cure (SDI), se seccionaron (palillos de dientes de 1,0 × 1,0 mm) y se sometieron a la prueba de fuerza de unión por microtensión y un régimen de termociclado (CT). En el análisis inmediato, todos los grupos contaminados sin limpieza tuvieron los siguientes valores de adhesión en comparación con el grupo de control. Después del termociclado, en los grupos sin limpieza solo se identificó el hemostático al control. Los grupos Sa mantuvieron el estándar de análisis inmediato, mientras que los grupos Sg fueron similares al control, independientemente del tiempo analizado. Los grupos H eran similares entre sí. En conclusión, los contaminantes probados perjudicaron la adhesión inmediata del material ionomérico a la dentina. El reacondicionamiento del sustrato fue eficaz en muestras contaminadas con saliva y agente hemostático. Sin embargo, los valores de la fuerza de unión se reducen después del envejecimiento.Este estudo teve como objetivo avaliar o efeito da contaminação dentinária e técnicas de limpeza na resistência de união das interfaces ionômero de vidro modificado por resina (RMGI) / dentina. 168 dentes bovinos foram selecionados e divididos em doze grupos (n = 14), de acordo com o contaminante agente (S - sem contaminação; Sa - saliva; Sg - sangue; H - hemostático) e técnica de limpeza (S - sem limpeza; A - spray de ar e água; P - recondicionamento de ácido poliacrílico 26%). Todos os espécimes foram restaurados com material ionomérico Riva Light Cure (SDI), seccionados (palitos de 1,0 x 1,0 mm) e submetidos ao teste de microtração de união e regime de termociclagem (CT). Na análise imediata, todos os grupos contaminados sem limpeza apresentaram os seguintes valores de adesão quando comparados com o grupo controle. Após a termociclagem, nos grupos sem limpeza apenas o hemostático foi identificado para o controle. Os grupos Sa mantiveram o padrão de análise imediata, enquanto os grupos Sg foram semelhantes ao controle, independente do tempo analisado. Os grupos H eram semelhantes entre si. Em conclusão, os contaminantes testados prejudicaram a adesão imediata do material ionomérico à dentina. O recondicionamento do substrato foi eficaz em amostras contaminadas com saliva e agente hemostático. No entanto, os valores de resistência de união reduziram após o envelhecimento.Research, Society and Development2021-06-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1598310.33448/rsd-v10i6.15983Research, Society and Development; Vol. 10 No. 6; e53310615983Research, Society and Development; Vol. 10 Núm. 6; e53310615983Research, Society and Development; v. 10 n. 6; e533106159832525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/15983/14384Copyright (c) 2021 Morganna Borges de Almeida; Paulo Henrique dos Santos; Lara Maria Bueno Esteves; Lívia Maria Alves Valentim da Silva; Marjorie de Oliveira Gallinari; Ticiane Cestari Fagundes; Giulia Bessa de Mello Antonnaccio; André Luiz Fraga Brisohttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessAlmeida, Morganna Borges deSantos, Paulo Henrique dos Esteves, Lara Maria Bueno Silva, Lívia Maria Alves Valentim da Gallinari, Marjorie de Oliveira Fagundes, Ticiane Cestari Antonnaccio, Giulia Bessa de MelloBriso, André Luiz Fraga 2021-06-10T22:51:46Zoai:ojs.pkp.sfu.ca:article/15983Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:36:40.648513Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Effect of dentin contamination and cleaning on the bond strength of resin-modified glass ionomer cement
Efecto de la contaminación y la limpieza de la dentina sobre la fuerza de unión del cemento de ionómero de vidrio modificado con resina
Efeito da contaminação e limpeza da dentina na resistência de união do cimento de ionômero de vidro modificado por resina
title Effect of dentin contamination and cleaning on the bond strength of resin-modified glass ionomer cement
spellingShingle Effect of dentin contamination and cleaning on the bond strength of resin-modified glass ionomer cement
Almeida, Morganna Borges de
Contaminação
Odontologia
Cimentos de ionômero de vidro
Resistência à tração.
Contamination
Dentistry
Glass ionomer cements
Tensile strength.
Contaminación
Odontología
Cementos de ionómero de vidrio
Fuerza de tensión.
title_short Effect of dentin contamination and cleaning on the bond strength of resin-modified glass ionomer cement
title_full Effect of dentin contamination and cleaning on the bond strength of resin-modified glass ionomer cement
title_fullStr Effect of dentin contamination and cleaning on the bond strength of resin-modified glass ionomer cement
title_full_unstemmed Effect of dentin contamination and cleaning on the bond strength of resin-modified glass ionomer cement
title_sort Effect of dentin contamination and cleaning on the bond strength of resin-modified glass ionomer cement
author Almeida, Morganna Borges de
author_facet Almeida, Morganna Borges de
Santos, Paulo Henrique dos
Esteves, Lara Maria Bueno
Silva, Lívia Maria Alves Valentim da
Gallinari, Marjorie de Oliveira
Fagundes, Ticiane Cestari
Antonnaccio, Giulia Bessa de Mello
Briso, André Luiz Fraga
author_role author
author2 Santos, Paulo Henrique dos
Esteves, Lara Maria Bueno
Silva, Lívia Maria Alves Valentim da
Gallinari, Marjorie de Oliveira
Fagundes, Ticiane Cestari
Antonnaccio, Giulia Bessa de Mello
Briso, André Luiz Fraga
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Almeida, Morganna Borges de
Santos, Paulo Henrique dos
Esteves, Lara Maria Bueno
Silva, Lívia Maria Alves Valentim da
Gallinari, Marjorie de Oliveira
Fagundes, Ticiane Cestari
Antonnaccio, Giulia Bessa de Mello
Briso, André Luiz Fraga
dc.subject.por.fl_str_mv Contaminação
Odontologia
Cimentos de ionômero de vidro
Resistência à tração.
Contamination
Dentistry
Glass ionomer cements
Tensile strength.
Contaminación
Odontología
Cementos de ionómero de vidrio
Fuerza de tensión.
topic Contaminação
Odontologia
Cimentos de ionômero de vidro
Resistência à tração.
Contamination
Dentistry
Glass ionomer cements
Tensile strength.
Contaminación
Odontología
Cementos de ionómero de vidrio
Fuerza de tensión.
description This study aimed to evaluate the effect of dentin contamination and cleaning techniques on the bond strength of resin-modified glass ionomer (RMGI)/dentin interfaces.168 bovine teeth were selected and divided into twelve groups (n = 14), according to the contaminating agent (S - no contamination; Sa - saliva; Sg - blood; H - hemostatic) and cleaning technique (S - without cleaning; A - air and water spray; P - polyacrylic acid reconditioning 26%). All specimens were restored with Riva Light Cure (SDI) ionomeric material, sectioned (1.0 × 1.0 mm toothpicks), and subjected to the microtensile bond strength test and a thermocycling regimen (CT).  In the immediate analysis, all contaminated groups without cleaning had the following adhesion values when compared with the control group. After thermocycling, in the groups without cleaning only the hemostatic was identified to the control. The Sa groups maintained the immediate analysis standard, while the Sg groups were similar to the control, regardless of the time analyzed. Groups H were similar to each other. In conclusion, the contaminants tested impaired the immediate adhesion of the ionomeric material to dentin. Substrate reconditioning was effective in specimens contaminated with saliva and hemostatic agent. However, bond strength values reduced after aging.
publishDate 2021
dc.date.none.fl_str_mv 2021-06-08
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/15983
10.33448/rsd-v10i6.15983
url https://rsdjournal.org/index.php/rsd/article/view/15983
identifier_str_mv 10.33448/rsd-v10i6.15983
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/15983/14384
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 10 No. 6; e53310615983
Research, Society and Development; Vol. 10 Núm. 6; e53310615983
Research, Society and Development; v. 10 n. 6; e53310615983
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052806869286912