Superficial temperature analysis on roof tiles coated with PVC waterproofing membrane

Detalhes bibliográficos
Autor(a) principal: Freitas, Márcia Regina
Data de Publicação: 2021
Outros Autores: Müller, Matheus, Porciúncula, Victor Rodrigues Gomes
Tipo de documento: Artigo
Idioma: por
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/19415
Resumo: The search for built environments with better air conditioning for the user is a growing interest in civil construction, in addition to guaranteeing a watertight environment, without infiltration and being able to provide environments with milder temperatures. In this sense, the objective of this work was to evaluate whether the use of waterproofing PVC coating improves thermal comfort in buildings. The tests were carried out at laboratory and field conditions, evaluating the temperature variation on the faces of tiles with and without waterproofing PVC coating. In the laboratory, surface temperatures were evaluated under the incidence of light from a reflector. In the field, direct sunlight was measured. The results showed that the use of PVC coating acts as a waterproofing agent, and as reflector of solar radiation, providing a difference between the external and internal temperature in the tile of about 20°C. The use of waterproofing PVC coating for thermal improvement in buildings is effective, resulting in the reflection of part of the solar radiation incident on the covering surface of buildings, hindering the passage of heat to the internal area.
id UNIFEI_0e09ed5981bc693546be78ea86f256ce
oai_identifier_str oai:ojs.pkp.sfu.ca:article/19415
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Superficial temperature analysis on roof tiles coated with PVC waterproofing membraneAnálisis de la variación de temperatura en baldosas revestidas con manta impermeable de PVCAnálise da variação de temperaturas em telhas revestidas com manta impermeabilizante de PVCTilesPVC coatingThermal evalutation.TejasManta de PVCThe search for built environments with better air conditioning for the user is a growing interest in civil construction, in addition to guaranteeing a watertight environment, without infiltration and being able to provide environments with milder temperatures. In this sense, the objective of this work was to evaluate whether the use of waterproofing PVC coating improves thermal comfort in buildings. The tests were carried out at laboratory and field conditions, evaluating the temperature variation on the faces of tiles with and without waterproofing PVC coating. In the laboratory, surface temperatures were evaluated under the incidence of light from a reflector. In the field, direct sunlight was measured. The results showed that the use of PVC coating acts as a waterproofing agent, and as reflector of solar radiation, providing a difference between the external and internal temperature in the tile of about 20°C. The use of waterproofing PVC coating for thermal improvement in buildings is effective, resulting in the reflection of part of the solar radiation incident on the covering surface of buildings, hindering the passage of heat to the internal area.La búsqueda de ambientes construidos con mejor climatización para el usuario es un interés creciente por la construcción civil, además de asegurar un ambiente estanco, sin infiltraciones para poder proporcionar ambientes con temperaturas más suaves. En este sentido, el objetivo de este estudio fue evaluar si el uso de una manta de PVC impermeabilizante mejora el confort térmico en los edificios. Las pruebas se realizaron en laboratorio y en campo, evaluando la variación de temperatura en los lados opuestos de tejas con y sin revestimiento con manta de PVC impermeabilizante. En laboratorio, se evaluaron las temperaturas de la superficie bajo la incidencia de la luz de un reflector. En campo, la medición se realizó sobre la incidencia directa del sol. Los resultados permitieron concluir que la manta no solo actúa como agente impermeabilizante, pero también como reflector de la radiación solar, proporcionando una diferencia entre la temperatura externa e interna en la teja de hasta 20 °C. El uso de mantas de PVC impermeables para la mejora térmica en los edificios es eficaz, provocando el reflejo de parte de la radiación solar incidente en la superficie de la cubierta del edificio, dificultando el paso del calor hacia el interior.A busca por ambientes construídos com melhor climatização para o usuário é um interesse crescente na construção civil, além de garantir um ambiente com estanqueidade, sem infiltrações e poder proporcionar ambientes com temperaturas mais amenas. Neste sentido, o objetivo deste trabalho foi avaliar se a utilização de manta impermeabilizante de PVC melhora o conforto térmico em edificações. Os ensaios foram realizados em laboratório e em campo, avaliando a variação de temperatura nas faces opostas de telhas com e sem revestimento em manta impermeabilizante de PVC. Em laboratório as temperaturas superficiais foram avaliadas sob a incidência de luz de um refletor. Em campo, fez-se a medição sobre incidência direta do sol. Os resultados permitiram concluir que a manta não atua somente como impermeabilizante, mas como refletor da radiação solar, proporcionando uma diferença entre a temperatura externa e interna na telha de até 20°C. O uso de mantas impermeabilizantes de PVC para a melhora térmica em edificações é efetivo, acarretando reflexão de parte da radiação solar incidente sobre a superfície de cobertura da edificação, dificultando a passagem de calor para a área interna.Research, Society and Development2021-08-27info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1941510.33448/rsd-v10i11.19415Research, Society and Development; Vol. 10 No. 11; e172101119415Research, Society and Development; Vol. 10 Núm. 11; e172101119415Research, Society and Development; v. 10 n. 11; e1721011194152525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/19415/17401Copyright (c) 2021 Márcia Regina Freitas; Matheus Müller; Victor Rodrigues Gomes Porciúnculahttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessFreitas, Márcia Regina Müller, MatheusPorciúncula, Victor Rodrigues Gomes 2021-10-23T19:01:11Zoai:ojs.pkp.sfu.ca:article/19415Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:39:18.992962Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Superficial temperature analysis on roof tiles coated with PVC waterproofing membrane
Análisis de la variación de temperatura en baldosas revestidas con manta impermeable de PVC
Análise da variação de temperaturas em telhas revestidas com manta impermeabilizante de PVC
title Superficial temperature analysis on roof tiles coated with PVC waterproofing membrane
spellingShingle Superficial temperature analysis on roof tiles coated with PVC waterproofing membrane
Freitas, Márcia Regina
Tiles
PVC coating
Thermal evalutation.
Tejas
Manta de PVC
title_short Superficial temperature analysis on roof tiles coated with PVC waterproofing membrane
title_full Superficial temperature analysis on roof tiles coated with PVC waterproofing membrane
title_fullStr Superficial temperature analysis on roof tiles coated with PVC waterproofing membrane
title_full_unstemmed Superficial temperature analysis on roof tiles coated with PVC waterproofing membrane
title_sort Superficial temperature analysis on roof tiles coated with PVC waterproofing membrane
author Freitas, Márcia Regina
author_facet Freitas, Márcia Regina
Müller, Matheus
Porciúncula, Victor Rodrigues Gomes
author_role author
author2 Müller, Matheus
Porciúncula, Victor Rodrigues Gomes
author2_role author
author
dc.contributor.author.fl_str_mv Freitas, Márcia Regina
Müller, Matheus
Porciúncula, Victor Rodrigues Gomes
dc.subject.por.fl_str_mv Tiles
PVC coating
Thermal evalutation.
Tejas
Manta de PVC
topic Tiles
PVC coating
Thermal evalutation.
Tejas
Manta de PVC
description The search for built environments with better air conditioning for the user is a growing interest in civil construction, in addition to guaranteeing a watertight environment, without infiltration and being able to provide environments with milder temperatures. In this sense, the objective of this work was to evaluate whether the use of waterproofing PVC coating improves thermal comfort in buildings. The tests were carried out at laboratory and field conditions, evaluating the temperature variation on the faces of tiles with and without waterproofing PVC coating. In the laboratory, surface temperatures were evaluated under the incidence of light from a reflector. In the field, direct sunlight was measured. The results showed that the use of PVC coating acts as a waterproofing agent, and as reflector of solar radiation, providing a difference between the external and internal temperature in the tile of about 20°C. The use of waterproofing PVC coating for thermal improvement in buildings is effective, resulting in the reflection of part of the solar radiation incident on the covering surface of buildings, hindering the passage of heat to the internal area.
publishDate 2021
dc.date.none.fl_str_mv 2021-08-27
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/19415
10.33448/rsd-v10i11.19415
url https://rsdjournal.org/index.php/rsd/article/view/19415
identifier_str_mv 10.33448/rsd-v10i11.19415
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/19415/17401
dc.rights.driver.fl_str_mv Copyright (c) 2021 Márcia Regina Freitas; Matheus Müller; Victor Rodrigues Gomes Porciúncula
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2021 Márcia Regina Freitas; Matheus Müller; Victor Rodrigues Gomes Porciúncula
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 10 No. 11; e172101119415
Research, Society and Development; Vol. 10 Núm. 11; e172101119415
Research, Society and Development; v. 10 n. 11; e172101119415
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052687621029888