Evaluation of pulp vitality using a pulse oximeter in patients undergoing radiotherapy for rhabdomyosarcoma or rhinopharynxcarcinoma

Detalhes bibliográficos
Autor(a) principal: Lopes, Rafael Paiva
Data de Publicação: 2021
Outros Autores: Akisue, Eduardo, Nakamura, Vitor Cesar, Caldeira, Celso Luiz, Lemos, Érico de Mello, Carrillo, Camila Merida, Rojz, Juliana Castilho Chaves, Caran, Eliana Maria Monteiro
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/19342
Resumo: The oral cavity is highly susceptible to pathological changes due to the deleterious effects of radiation (RI) on tissues exposed during radiotherapy (RT). The aim of this study was to evaluate the feasibility of using pulse oximeter (PO) as a diagnostic instrument for assessing the pulp oxygenation level (%SpO2) of immature teeth previously exposure to IR. Pulp oxygenation saturation was evaluated in fifteen children or adolescent patients (Group RT) that received previous IR, 6.01 years ago (SD 4.08 years), and fifteen patients without a history of neoplasms or previous chemotherapy or radiotherapy (CO group). As result, the mean %SpO2 measured in Group RT and Group CO was 86.06% (SD 1.61%) and 91.11% (SD 0.87%), respectively. Conclusions: The use of the pulse oximeter adapted for dentistry for pulpal vitality evaluation in patients who received radiotherapy is feasible showing lower level of SpO2 than that of the control group (p<0.05).
id UNIFEI_15f5946ba5668a247d597ee084e8c23d
oai_identifier_str oai:ojs.pkp.sfu.ca:article/19342
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Evaluation of pulp vitality using a pulse oximeter in patients undergoing radiotherapy for rhabdomyosarcoma or rhinopharynxcarcinomaEvaluación de la vitalidad pulpar usando el oxímetro de pulso en pacientes que pasaron por radioterapia para rabdomiosarcoma o carcinoma de rinofaringeAvaliação da vitalidade pulpar utilizando o oximetro de pulso em pacientes submetidos à radioterapia para rabdomiossarcoma ou carcinoma de rinofaringePulpa dentalOximetriaRadioterapiaRabdomiosarcomaCarcinoma rinofaríngeo.Dental pulpOximetryRadiotherapyRhabdomyosarcomaRinopharyngeal carcinoma.Polpa dentáriaOximetriaRadioterapiaRabdomiossarcomaCarcinoma rinofaríngeo.The oral cavity is highly susceptible to pathological changes due to the deleterious effects of radiation (RI) on tissues exposed during radiotherapy (RT). The aim of this study was to evaluate the feasibility of using pulse oximeter (PO) as a diagnostic instrument for assessing the pulp oxygenation level (%SpO2) of immature teeth previously exposure to IR. Pulp oxygenation saturation was evaluated in fifteen children or adolescent patients (Group RT) that received previous IR, 6.01 years ago (SD 4.08 years), and fifteen patients without a history of neoplasms or previous chemotherapy or radiotherapy (CO group). As result, the mean %SpO2 measured in Group RT and Group CO was 86.06% (SD 1.61%) and 91.11% (SD 0.87%), respectively. Conclusions: The use of the pulse oximeter adapted for dentistry for pulpal vitality evaluation in patients who received radiotherapy is feasible showing lower level of SpO2 than that of the control group (p<0.05).Los tejidos de la cavidad oral son altamente suceptibles a las alteraciones patológicas devido a los efectos colaterales de la radiación (RI) originados por la radioterapia (RT). El objetivo de este estúdio fue analizar la viabilidad del uso del oxímetro de pulso (PO) como herramienta para evaluar el nivel de oxígeno pulpar (% SpO2) en dientes inmaduros anteriormente expuestos a RI.  La saturación del oxígeno pulpar fue evaluada en quince niños o adolecentes (Grupo RT) que recibieron RT anteriormente hace 6,01 años (SD 4,08 años) y quince pacientes sin historia de neoplasmas o quimioterapia o radioterapia anterior (Grupo CO). Como resultado, la % SpO2 media obtenida en el grupo RT y en el grupo CO fue de 86,06% (SD 1,61%) y 91,11% (SD 0,87%), respectivamente. Conclusiones: La utilización del oxímetro de pulso adaptado para la odontologia en la avaliación de la vitalidad pulpar em pacientes que recibieron radioterapia es viable mostrando um nivel de SpO2 inferior al del grupo control (p<0.05).A cavidade oral é altamente suscetível a alterações patológicas devido aos efeitos deletérios da radiação (RI) nos tecidos expostos durante a radioterapia (RT). O objetivo deste estudo foi avaliar a viabilidade do uso do oxímetro de pulso (PO) como instrumento de diagnóstico na avaliação do nível de oxigenação pulpar (% SpO2) de dentes imaturos previamente expostos à RI. A saturação da oxigenação pulpar foi avaliada em quinze crianças ou adolescentes (Grupo RT) que receberam RI prévia há 6,01 anos (SD  4,08 anos), e em quinze pacientes sem história de neoplasias ou quimioterapia ou radioterapia prévia (grupo CO). Como resultado, a %SpO2 média medida no Grupo RT e Grupo CO foi de 86,06% (SD 1,61%) e 91,11% (SD 0,87%), respectivamente. Conclusão: A utilização do oxímetro de pulso adaptado para odontologia na avaliação da vitalidade pulpar em pacientes que receberam radioterapia é viável apresentando nível de SpO2 inferior ao do grupo controle (p<0.05).Research, Society and Development2021-08-24info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1934210.33448/rsd-v10i11.19342Research, Society and Development; Vol. 10 No. 11; e107101119342Research, Society and Development; Vol. 10 Núm. 11; e107101119342Research, Society and Development; v. 10 n. 11; e1071011193422525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIenghttps://rsdjournal.org/index.php/rsd/article/view/19342/17312Copyright (c) 2021 Rafael Paiva Lopes; Eduardo Akisue; Vitor Cesar Nakamura; Celso Luiz Caldeira; Érico de Mello Lemos; Camila Merida Carrillo; Juliana Castilho Chaves Rojz; Eliana Maria Monteiro Caranhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessLopes, Rafael Paiva Akisue, Eduardo Nakamura, Vitor Cesar Caldeira, Celso Luiz Lemos, Érico de Mello Carrillo, Camila Merida Rojz, Juliana Castilho Chaves Caran, Eliana Maria Monteiro2021-10-23T19:01:11Zoai:ojs.pkp.sfu.ca:article/19342Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:39:15.258274Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Evaluation of pulp vitality using a pulse oximeter in patients undergoing radiotherapy for rhabdomyosarcoma or rhinopharynxcarcinoma
Evaluación de la vitalidad pulpar usando el oxímetro de pulso en pacientes que pasaron por radioterapia para rabdomiosarcoma o carcinoma de rinofaringe
Avaliação da vitalidade pulpar utilizando o oximetro de pulso em pacientes submetidos à radioterapia para rabdomiossarcoma ou carcinoma de rinofaringe
title Evaluation of pulp vitality using a pulse oximeter in patients undergoing radiotherapy for rhabdomyosarcoma or rhinopharynxcarcinoma
spellingShingle Evaluation of pulp vitality using a pulse oximeter in patients undergoing radiotherapy for rhabdomyosarcoma or rhinopharynxcarcinoma
Lopes, Rafael Paiva
Pulpa dental
Oximetria
Radioterapia
Rabdomiosarcoma
Carcinoma rinofaríngeo.
Dental pulp
Oximetry
Radiotherapy
Rhabdomyosarcoma
Rinopharyngeal carcinoma.
Polpa dentária
Oximetria
Radioterapia
Rabdomiossarcoma
Carcinoma rinofaríngeo.
title_short Evaluation of pulp vitality using a pulse oximeter in patients undergoing radiotherapy for rhabdomyosarcoma or rhinopharynxcarcinoma
title_full Evaluation of pulp vitality using a pulse oximeter in patients undergoing radiotherapy for rhabdomyosarcoma or rhinopharynxcarcinoma
title_fullStr Evaluation of pulp vitality using a pulse oximeter in patients undergoing radiotherapy for rhabdomyosarcoma or rhinopharynxcarcinoma
title_full_unstemmed Evaluation of pulp vitality using a pulse oximeter in patients undergoing radiotherapy for rhabdomyosarcoma or rhinopharynxcarcinoma
title_sort Evaluation of pulp vitality using a pulse oximeter in patients undergoing radiotherapy for rhabdomyosarcoma or rhinopharynxcarcinoma
author Lopes, Rafael Paiva
author_facet Lopes, Rafael Paiva
Akisue, Eduardo
Nakamura, Vitor Cesar
Caldeira, Celso Luiz
Lemos, Érico de Mello
Carrillo, Camila Merida
Rojz, Juliana Castilho Chaves
Caran, Eliana Maria Monteiro
author_role author
author2 Akisue, Eduardo
Nakamura, Vitor Cesar
Caldeira, Celso Luiz
Lemos, Érico de Mello
Carrillo, Camila Merida
Rojz, Juliana Castilho Chaves
Caran, Eliana Maria Monteiro
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Lopes, Rafael Paiva
Akisue, Eduardo
Nakamura, Vitor Cesar
Caldeira, Celso Luiz
Lemos, Érico de Mello
Carrillo, Camila Merida
Rojz, Juliana Castilho Chaves
Caran, Eliana Maria Monteiro
dc.subject.por.fl_str_mv Pulpa dental
Oximetria
Radioterapia
Rabdomiosarcoma
Carcinoma rinofaríngeo.
Dental pulp
Oximetry
Radiotherapy
Rhabdomyosarcoma
Rinopharyngeal carcinoma.
Polpa dentária
Oximetria
Radioterapia
Rabdomiossarcoma
Carcinoma rinofaríngeo.
topic Pulpa dental
Oximetria
Radioterapia
Rabdomiosarcoma
Carcinoma rinofaríngeo.
Dental pulp
Oximetry
Radiotherapy
Rhabdomyosarcoma
Rinopharyngeal carcinoma.
Polpa dentária
Oximetria
Radioterapia
Rabdomiossarcoma
Carcinoma rinofaríngeo.
description The oral cavity is highly susceptible to pathological changes due to the deleterious effects of radiation (RI) on tissues exposed during radiotherapy (RT). The aim of this study was to evaluate the feasibility of using pulse oximeter (PO) as a diagnostic instrument for assessing the pulp oxygenation level (%SpO2) of immature teeth previously exposure to IR. Pulp oxygenation saturation was evaluated in fifteen children or adolescent patients (Group RT) that received previous IR, 6.01 years ago (SD 4.08 years), and fifteen patients without a history of neoplasms or previous chemotherapy or radiotherapy (CO group). As result, the mean %SpO2 measured in Group RT and Group CO was 86.06% (SD 1.61%) and 91.11% (SD 0.87%), respectively. Conclusions: The use of the pulse oximeter adapted for dentistry for pulpal vitality evaluation in patients who received radiotherapy is feasible showing lower level of SpO2 than that of the control group (p<0.05).
publishDate 2021
dc.date.none.fl_str_mv 2021-08-24
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/19342
10.33448/rsd-v10i11.19342
url https://rsdjournal.org/index.php/rsd/article/view/19342
identifier_str_mv 10.33448/rsd-v10i11.19342
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/19342/17312
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 10 No. 11; e107101119342
Research, Society and Development; Vol. 10 Núm. 11; e107101119342
Research, Society and Development; v. 10 n. 11; e107101119342
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052687431237632