The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical report
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Research, Society and Development |
Texto Completo: | https://rsdjournal.org/index.php/rsd/article/view/10692 |
Resumo: | The objective of this case report was to describe the clinical sequence for occlusal vertical dimension (OVD) recovering with the manufacture of removable partial dentures (RPD) produced by computer-aided design and rapid prototyping. The patient presented to the Dentistry Department of the Federal University of Rio Grande do Norte reporting dissatisfaction with the superior RPD. At clinical investigation, a fracture in the minor connector and support at the region of tooth 15 was observed, in addition to severe OVD loss. In this case, after obtaining correct OVD, four more sessions were necessary for RPD fabrication. In the first appointment, intraoral scanning was performed to generate STL files used for path of insertion determination in the CAD software. The need for a guide plane on tooth 15 was observed, thus a preparation guide was designed and 3Dprinted to aid axial tooth reduction. At the second visit, after mouth preparation, another intraoral scanning was performed to acquire virtual working models. The RPD framework was designed and 3D printed in a castable resin pattern and invested for cobalt-chromium alloy melting. In the third visit, clinical evaluation of the framework and teeth and artificial gingiva colors selection were performed. The articulated models were then 3D printed, enabling pre-fabricated teeth to be assembled and acrylized. On the fourth appointment, RPD was installed and the patient received routine instructions. In this sense, the use of CAD/CAM technologies presented as a valuable tool to enhance restoration of OVD by the manufacturing of RPD. |
id |
UNIFEI_22de1aa4f83c3308387bb53211d96fb9 |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/10692 |
network_acronym_str |
UNIFEI |
network_name_str |
Research, Society and Development |
repository_id_str |
|
spelling |
The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical reportEl diseño asistido por computadora y la fabricación rápida de prototipos de estructuras de prótesis parciales removibles para rehabilitación oclusal: informe clínicoProjeto auxiliado por computador e prototipagem rápida para fabricação de estrutura de prótese parcial removível para reabilitação oclusal: relatório clínicoDentadura ParcialImpresión TridimensionalDiseño Asistido por ComputadoraDimensión Vertical.Prótese Parcial RemovívelImpressão TridimensionalProjeto Auxiliado por ComputadorDimensão Vertical.Removable Partial Denture3D PrintingComputer Aided DesignVertical Dimension of Occlusion.The objective of this case report was to describe the clinical sequence for occlusal vertical dimension (OVD) recovering with the manufacture of removable partial dentures (RPD) produced by computer-aided design and rapid prototyping. The patient presented to the Dentistry Department of the Federal University of Rio Grande do Norte reporting dissatisfaction with the superior RPD. At clinical investigation, a fracture in the minor connector and support at the region of tooth 15 was observed, in addition to severe OVD loss. In this case, after obtaining correct OVD, four more sessions were necessary for RPD fabrication. In the first appointment, intraoral scanning was performed to generate STL files used for path of insertion determination in the CAD software. The need for a guide plane on tooth 15 was observed, thus a preparation guide was designed and 3Dprinted to aid axial tooth reduction. At the second visit, after mouth preparation, another intraoral scanning was performed to acquire virtual working models. The RPD framework was designed and 3D printed in a castable resin pattern and invested for cobalt-chromium alloy melting. In the third visit, clinical evaluation of the framework and teeth and artificial gingiva colors selection were performed. The articulated models were then 3D printed, enabling pre-fabricated teeth to be assembled and acrylized. On the fourth appointment, RPD was installed and the patient received routine instructions. In this sense, the use of CAD/CAM technologies presented as a valuable tool to enhance restoration of OVD by the manufacturing of RPD.El objetivo de este reporte de caso fue describir la secuencia clínica del restablecimiento de la dimensión oclusal vertical (OVD) con la fabricación de prótesis parciales removibles (PPR) producidas por diseño asistido por computadora y prototipado rápido. El paciente se presentó al Departamento de Odontología de la Universidad Federal de Rio Grande do Norte, refiriendo insatisfacción con el PPR superior. Clínicamente se observó fractura del conector menor y soporte en la región del diente 15, además de pérdida de DVO. En este caso, tras el restablecimiento del DVO, fueron necesarias cuatro sesiones más para la fabricación del PPR. En el primero, se realizó un escaneo intraoral para obtener los archivos STL utilizados para determinar el eje de inserción en el software CAD. Se observó la necesidad de un plano guía en el diente 15, por lo que se diseñó e imprimió una guía de preparación en 3D para la reducción axial del diente. En el segundo tras la preparación de la boca, se realizó un nuevo escaneo intraoral para adquirir los modelos de trabajo virtuales. La estructura de PPR fue diseñada e impresa en un patrón de resina fundible y pensada para fundir la aleación de cobalto-cromo. En el tercero se realizó una evaluación clínica de la estructura y selección de los dientes y el color de la encía artificial. A continuación, los modelos articulados se imprimieron en 3D, lo que permitió el montaje y la acrilación de los dientes prefabricados. En el cuarto, se instaló el PPR y el paciente recibió instrucciones de rutina. Así, el uso de tecnologías CAD-CAM se presenta como una valiosa herramienta para la fabricación de PPR con la necesidad de restablecer DVO.O objetivo deste relato de caso foi descrever a sequência clínica do reestabelecimento da dimensão vertical oclusal (OVD) com a confecção de próteses parciais removíveis (PPR) produzida por desenho auxiliado por computador e prototipagem rápida. A paciente apresentou-se ao Departamento de Odontologia da Universidade Federal do Rio Grande do Norte, relatando insatisfação com o PPR superior. Clinicamente, observou-se fratura do conector menor e apoio na região do dente 15, além de perda de DVO. Neste caso, após o reestabelecimento da DVO, mais quatro sessões foram necessárias para a fabricação da PPR. Na primeira, foi realizado o escaneamento intraoral para obtenção dos arquivos STL utilizados para determinação do eixo de inserção no software CAD. Observou-se a necessidade de um plano-guia no dente 15, portanto, um guia de preparo foi desenhado e impresso em 3D para redução axial do dente. Na segunda, após o preparo de boca, foi realizada um novo escaneamento intraoral para aquisição dos modelos virtuais de trabalho. A estrutura da PPR foi projetada e impressa em um padrão de resina fundível e destinada à fusão da liga de cobalto-cromo. Na terceira, foi realizada uma avaliação clínica da estrutura e seleção dos dentes e cor da gengiva artificial. Os modelos articulados foram então impressos em 3D, permitindo a montagem e acrilização dos dentes pré-fabricados. Na quarta, a PPR foi instalada e o paciente recebeu instruções de rotina. Assim, o uso de tecnologias CAD-CAM se apresenta como uma ferramenta valiosa para a fabricação de PPR com necessidade de reestabelecimento de DVO.Research, Society and Development2020-12-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1069210.33448/rsd-v9i12.10692Research, Society and Development; Vol. 9 No. 12; e9891210692Research, Society and Development; Vol. 9 Núm. 12; e9891210692Research, Society and Development; v. 9 n. 12; e98912106922525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIenghttps://rsdjournal.org/index.php/rsd/article/view/10692/9706Copyright (c) 2020 Adriana da Fonte Porto Carreiro; Ana Larisse Carneiro Pereira; Camila Oliveira Paz; Rachel Gomes Cardoso; Clebya Rosália Pereira Medeiros; Annie Karoline Bezerra de Medeiros; Rodrigo Falcão Carvalho Porto de Freitas https://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessCarreiro, Adriana da Fonte Porto Pereira, Ana Larisse CarneiroPaz, Camila Oliveira Cardoso, Rachel Gomes Medeiros, Clebya Rosália Pereira Medeiros, Annie Karoline Bezerra de Freitas , Rodrigo Falcão Carvalho Porto de 2020-12-30T23:32:22Zoai:ojs.pkp.sfu.ca:article/10692Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:32:42.372291Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false |
dc.title.none.fl_str_mv |
The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical report El diseño asistido por computadora y la fabricación rápida de prototipos de estructuras de prótesis parciales removibles para rehabilitación oclusal: informe clínico Projeto auxiliado por computador e prototipagem rápida para fabricação de estrutura de prótese parcial removível para reabilitação oclusal: relatório clínico |
title |
The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical report |
spellingShingle |
The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical report Carreiro, Adriana da Fonte Porto Dentadura Parcial Impresión Tridimensional Diseño Asistido por Computadora Dimensión Vertical. Prótese Parcial Removível Impressão Tridimensional Projeto Auxiliado por Computador Dimensão Vertical. Removable Partial Denture 3D Printing Computer Aided Design Vertical Dimension of Occlusion. |
title_short |
The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical report |
title_full |
The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical report |
title_fullStr |
The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical report |
title_full_unstemmed |
The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical report |
title_sort |
The computer-aided design and rapid prototyping fabrication of removable partial denture framework for occlusal rehabilitation: clinical report |
author |
Carreiro, Adriana da Fonte Porto |
author_facet |
Carreiro, Adriana da Fonte Porto Pereira, Ana Larisse Carneiro Paz, Camila Oliveira Cardoso, Rachel Gomes Medeiros, Clebya Rosália Pereira Medeiros, Annie Karoline Bezerra de Freitas , Rodrigo Falcão Carvalho Porto de |
author_role |
author |
author2 |
Pereira, Ana Larisse Carneiro Paz, Camila Oliveira Cardoso, Rachel Gomes Medeiros, Clebya Rosália Pereira Medeiros, Annie Karoline Bezerra de Freitas , Rodrigo Falcão Carvalho Porto de |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Carreiro, Adriana da Fonte Porto Pereira, Ana Larisse Carneiro Paz, Camila Oliveira Cardoso, Rachel Gomes Medeiros, Clebya Rosália Pereira Medeiros, Annie Karoline Bezerra de Freitas , Rodrigo Falcão Carvalho Porto de |
dc.subject.por.fl_str_mv |
Dentadura Parcial Impresión Tridimensional Diseño Asistido por Computadora Dimensión Vertical. Prótese Parcial Removível Impressão Tridimensional Projeto Auxiliado por Computador Dimensão Vertical. Removable Partial Denture 3D Printing Computer Aided Design Vertical Dimension of Occlusion. |
topic |
Dentadura Parcial Impresión Tridimensional Diseño Asistido por Computadora Dimensión Vertical. Prótese Parcial Removível Impressão Tridimensional Projeto Auxiliado por Computador Dimensão Vertical. Removable Partial Denture 3D Printing Computer Aided Design Vertical Dimension of Occlusion. |
description |
The objective of this case report was to describe the clinical sequence for occlusal vertical dimension (OVD) recovering with the manufacture of removable partial dentures (RPD) produced by computer-aided design and rapid prototyping. The patient presented to the Dentistry Department of the Federal University of Rio Grande do Norte reporting dissatisfaction with the superior RPD. At clinical investigation, a fracture in the minor connector and support at the region of tooth 15 was observed, in addition to severe OVD loss. In this case, after obtaining correct OVD, four more sessions were necessary for RPD fabrication. In the first appointment, intraoral scanning was performed to generate STL files used for path of insertion determination in the CAD software. The need for a guide plane on tooth 15 was observed, thus a preparation guide was designed and 3Dprinted to aid axial tooth reduction. At the second visit, after mouth preparation, another intraoral scanning was performed to acquire virtual working models. The RPD framework was designed and 3D printed in a castable resin pattern and invested for cobalt-chromium alloy melting. In the third visit, clinical evaluation of the framework and teeth and artificial gingiva colors selection were performed. The articulated models were then 3D printed, enabling pre-fabricated teeth to be assembled and acrylized. On the fourth appointment, RPD was installed and the patient received routine instructions. In this sense, the use of CAD/CAM technologies presented as a valuable tool to enhance restoration of OVD by the manufacturing of RPD. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-12-14 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://rsdjournal.org/index.php/rsd/article/view/10692 10.33448/rsd-v9i12.10692 |
url |
https://rsdjournal.org/index.php/rsd/article/view/10692 |
identifier_str_mv |
10.33448/rsd-v9i12.10692 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://rsdjournal.org/index.php/rsd/article/view/10692/9706 |
dc.rights.driver.fl_str_mv |
https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Research, Society and Development |
publisher.none.fl_str_mv |
Research, Society and Development |
dc.source.none.fl_str_mv |
Research, Society and Development; Vol. 9 No. 12; e9891210692 Research, Society and Development; Vol. 9 Núm. 12; e9891210692 Research, Society and Development; v. 9 n. 12; e9891210692 2525-3409 reponame:Research, Society and Development instname:Universidade Federal de Itajubá (UNIFEI) instacron:UNIFEI |
instname_str |
Universidade Federal de Itajubá (UNIFEI) |
instacron_str |
UNIFEI |
institution |
UNIFEI |
reponame_str |
Research, Society and Development |
collection |
Research, Society and Development |
repository.name.fl_str_mv |
Research, Society and Development - Universidade Federal de Itajubá (UNIFEI) |
repository.mail.fl_str_mv |
rsd.articles@gmail.com |
_version_ |
1797052743436730368 |