Resumo: | This study evaluated the mechanical strength correlated to the percentage of the total volume of weld and porosities of Co-Cr alloy joints welded with TIG technique. Thirty specimens were perpendicularly sectioned to the long-axis and rejoined by using X30-shaped joint design with TIG welding. They were divided into 3 groups (n=10): the CG1 with a 60-A depth and 90-ms pulse; the CG2 with a 60-A depth and 120-ms pulse and the CG3 with a 60-A depth and 160-ms pulse. The specimens were submitted to nondestructive tests: radiographic inspection, penetrant liquid and Micro- CT (to calculate the percentage of the total volume of welding and the porosities) and then tested with 3-point bending. The fracture surfaces were analyzed with scanning electron microscopy (SEM). The data were statistically analyzed with 1-way ANOVA and the Tukey post hoc test for all the variables which were analyzed: flexural strength, total volume of weld and porosities. Pearson correlation test was also applied (ɑ=.05). The 1-way ANOVA showed that the factors machine parameters were not significant for flexural strength values (P=.231), the total volume of weld (P=.057) and porosities (P=.057). There are no significant relationships between any pair of variables after Pearson correlation test (P >.050). This, suggesting that the three machine regulation can be an option for joining prefabricated Co-Cr rods in this kind of union. |
id |
UNIFEI_32aae400fe299a3b03830b1ec97a1ca6 |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/14308 |
network_acronym_str |
UNIFEI |
network_name_str |
Research, Society and Development |
spelling |
Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strengthEvaluación de uniones soldadas em forma de X con aleación de Co-Cr bajo diferentes parámetros de soldadura: análisis por micro-CT y resistencia a la flexiónAvaliação de juntas soldadas em forma de X com liga de Co-Cr sob diferentes parâmetros de soldagem: análise por micro-CT e resistência à flexão Dental AlloysDental SolderingFlexural strength.Aleaciones dentalesSoldadura dentalFuerza flexible.Ligas metáligasSoldagem dentáriaResistência à flexão.This study evaluated the mechanical strength correlated to the percentage of the total volume of weld and porosities of Co-Cr alloy joints welded with TIG technique. Thirty specimens were perpendicularly sectioned to the long-axis and rejoined by using X30-shaped joint design with TIG welding. They were divided into 3 groups (n=10): the CG1 with a 60-A depth and 90-ms pulse; the CG2 with a 60-A depth and 120-ms pulse and the CG3 with a 60-A depth and 160-ms pulse. The specimens were submitted to nondestructive tests: radiographic inspection, penetrant liquid and Micro- CT (to calculate the percentage of the total volume of welding and the porosities) and then tested with 3-point bending. The fracture surfaces were analyzed with scanning electron microscopy (SEM). The data were statistically analyzed with 1-way ANOVA and the Tukey post hoc test for all the variables which were analyzed: flexural strength, total volume of weld and porosities. Pearson correlation test was also applied (ɑ=.05). The 1-way ANOVA showed that the factors machine parameters were not significant for flexural strength values (P=.231), the total volume of weld (P=.057) and porosities (P=.057). There are no significant relationships between any pair of variables after Pearson correlation test (P >.050). This, suggesting that the three machine regulation can be an option for joining prefabricated Co-Cr rods in this kind of union.Este estudio evaluó la resistencia mecánica, correlacionada con el porcentaje del volumen total de soldadura y la porosidad, de las uniones soldadas con Co-Cr con la técnica TIG en diferentes configuraciones del equipo. Treinta muestras se seccionaron perpendicularmente y se unieron con soldadura TIG con junta en forma de X. Se dividieron en 3 grupos (n = 10): el CG1 con una profundidad de 60 A y un pulso de 90 ms; el CG2 con una profundidad de 60 A y pulso de 120 ms y el CG3 con una profundidad de 60 A y un pulso de 160 ms. Las muestras fueron sometidas a ensayos no destructivos (inspección radiográfica, líquido penetrante y Micro-CT (para calcular el porcentaje del volumen total de soldadura y las porosidades)) y ensayados con flexión de 3 puntos. Las superficies de fractura se analizaron con microscopía electrónica de barrido (SEM). Los datos se analizaron estadísticamente con ANOVA one way y el test post hoc de Tukey para todas las variables analizadas: resistencia a la flexión, volumen total de soldadura y porosidades. También se aplicó la prueba de correlación de Pearson (ɑ = .05). ANOVA one way mostró que los factores parámetros de la máquina no fueron significativos para los valores de resistencia a la flexión (P = .231), el volumen total de soldadura (P = .057) y las porosidades (P = .057). No hay relaciones significativas entre ningún par de variables después de la prueba de correlación de Pearson (P> .050). Esto sugiere que las tres configuraciones del equipo pueden ser una opción para unir barras de Co-Cr prefabricadas en este tipo de unión.Este estudo avaliou a resistência mecânica, correlacionada ao percentual do volume total de solda e porosidades, de juntas soldadas de Co-Cr com a técnica TIG em diferentes regulagens do equipamento. Trinta amostras foram seccionadas perpendicularmente e unidas com soldagem TIG com junta em forma de X. Estas foram divididas em 3 grupos (n = 10): CG1 com profundidade de 60-A e pulso de 90 ms; CG2 com profundidade de 60 A e pulso de 120 ms e CG3 com profundidade de 60 A e pulso de 160 ms. As amostras foram submetidas a ensaios não destrutivos (inspeção radiográfica, líquido penetrante e Micro-CT (para cálculo do percentual do volume total de soldagem e das porosidades)) e ensaio de flexão em 3 pontos. As superfícies das fraturas foram analisadas em microscopia eletrônica de varredura (MEV). Os dados foram analisados estatisticamente com ANOVA one way e teste post hoc de Tukey para todas as variáveis analisadas: resistência à flexão, volume total de solda e porosidades. O teste de correlação de Pearson também foi aplicado (ɑ = 0,05). ANOVA one way mostrou que os fatores regulagem do equipamento não foram significativos para os valores de resistência à flexão (P = .231), volume total de solda (P = .057) e porosidades (P = .057). Não houve relações significativas entre qualquer par de variáveis após o teste de correlação de Pearson (P> 0,050). Isso sugere que as três regulagens do equipamento podem ser uma opção para unir barras pré-fabricadas de Co-Cr neste tipo de união.Research, Society and Development2021-04-17info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1430810.33448/rsd-v10i4.14308Research, Society and Development; Vol. 10 No. 4; e44510414308Research, Society and Development; Vol. 10 Núm. 4; e44510414308Research, Society and Development; v. 10 n. 4; e445104143082525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIenghttps://rsdjournal.org/index.php/rsd/article/view/14308/12872Copyright (c) 2021 Morgana Guilherme de Castro Silverio; Luís Henrique Araújo Raposo; Ricardo Tadeu Lopes; Paulo Cézar Simamoto Júniorhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccess Silverio, Morgana Guilherme de CastroRaposo, Luís Henrique AraújoLopes, Ricardo TadeuSimamoto Júnior, Paulo Cézar 2021-04-25T11:21:26Zoai:ojs.pkp.sfu.ca:article/14308Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:35:27.615654Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false |
dc.title.none.fl_str_mv |
Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strength Evaluación de uniones soldadas em forma de X con aleación de Co-Cr bajo diferentes parámetros de soldadura: análisis por micro-CT y resistencia a la flexión Avaliação de juntas soldadas em forma de X com liga de Co-Cr sob diferentes parâmetros de soldagem: análise por micro-CT e resistência à flexão |
title |
Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strength |
spellingShingle |
Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strength Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strength Silverio, Morgana Guilherme de Castro Dental Alloys Dental Soldering Flexural strength. Aleaciones dentales Soldadura dental Fuerza flexible. Ligas metáligas Soldagem dentária Resistência à flexão. Silverio, Morgana Guilherme de Castro Dental Alloys Dental Soldering Flexural strength. Aleaciones dentales Soldadura dental Fuerza flexible. Ligas metáligas Soldagem dentária Resistência à flexão. |
title_short |
Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strength |
title_full |
Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strength |
title_fullStr |
Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strength Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strength |
title_full_unstemmed |
Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strength Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strength |
title_sort |
Evaluation of X-shaped welded joints with Co-Cr alloy under different welding parameters: analysis by micro-CT and flexural strength |
author |
Silverio, Morgana Guilherme de Castro |
author_facet |
Silverio, Morgana Guilherme de Castro Silverio, Morgana Guilherme de Castro Raposo, Luís Henrique Araújo Lopes, Ricardo Tadeu Simamoto Júnior, Paulo Cézar Raposo, Luís Henrique Araújo Lopes, Ricardo Tadeu Simamoto Júnior, Paulo Cézar |
author_role |
author |
author2 |
Raposo, Luís Henrique Araújo Lopes, Ricardo Tadeu Simamoto Júnior, Paulo Cézar |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Silverio, Morgana Guilherme de Castro Raposo, Luís Henrique Araújo Lopes, Ricardo Tadeu Simamoto Júnior, Paulo Cézar |
dc.subject.por.fl_str_mv |
Dental Alloys Dental Soldering Flexural strength. Aleaciones dentales Soldadura dental Fuerza flexible. Ligas metáligas Soldagem dentária Resistência à flexão. |
topic |
Dental Alloys Dental Soldering Flexural strength. Aleaciones dentales Soldadura dental Fuerza flexible. Ligas metáligas Soldagem dentária Resistência à flexão. |
description |
This study evaluated the mechanical strength correlated to the percentage of the total volume of weld and porosities of Co-Cr alloy joints welded with TIG technique. Thirty specimens were perpendicularly sectioned to the long-axis and rejoined by using X30-shaped joint design with TIG welding. They were divided into 3 groups (n=10): the CG1 with a 60-A depth and 90-ms pulse; the CG2 with a 60-A depth and 120-ms pulse and the CG3 with a 60-A depth and 160-ms pulse. The specimens were submitted to nondestructive tests: radiographic inspection, penetrant liquid and Micro- CT (to calculate the percentage of the total volume of welding and the porosities) and then tested with 3-point bending. The fracture surfaces were analyzed with scanning electron microscopy (SEM). The data were statistically analyzed with 1-way ANOVA and the Tukey post hoc test for all the variables which were analyzed: flexural strength, total volume of weld and porosities. Pearson correlation test was also applied (ɑ=.05). The 1-way ANOVA showed that the factors machine parameters were not significant for flexural strength values (P=.231), the total volume of weld (P=.057) and porosities (P=.057). There are no significant relationships between any pair of variables after Pearson correlation test (P >.050). This, suggesting that the three machine regulation can be an option for joining prefabricated Co-Cr rods in this kind of union. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-04-17 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://rsdjournal.org/index.php/rsd/article/view/14308 10.33448/rsd-v10i4.14308 |
url |
https://rsdjournal.org/index.php/rsd/article/view/14308 |
identifier_str_mv |
10.33448/rsd-v10i4.14308 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://rsdjournal.org/index.php/rsd/article/view/14308/12872 |
dc.rights.driver.fl_str_mv |
https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Research, Society and Development |
publisher.none.fl_str_mv |
Research, Society and Development |
dc.source.none.fl_str_mv |
Research, Society and Development; Vol. 10 No. 4; e44510414308 Research, Society and Development; Vol. 10 Núm. 4; e44510414308 Research, Society and Development; v. 10 n. 4; e44510414308 2525-3409 reponame:Research, Society and Development instname:Universidade Federal de Itajubá (UNIFEI) instacron:UNIFEI |
instname_str |
Universidade Federal de Itajubá (UNIFEI) |
instacron_str |
UNIFEI |
institution |
UNIFEI |
reponame_str |
Research, Society and Development |
collection |
Research, Society and Development |
repository.name.fl_str_mv |
Research, Society and Development - Universidade Federal de Itajubá (UNIFEI) |
repository.mail.fl_str_mv |
rsd.articles@gmail.com |
_version_ |
1822178887464910848 |
dc.identifier.doi.none.fl_str_mv |
10.33448/rsd-v10i4.14308 |