Efficacy and safety of Carboxitherapy associated with High Volt current in the treatment of atrophic stretch marks on glutes
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Research, Society and Development |
Texto Completo: | https://rsdjournal.org/index.php/rsd/article/view/10430 |
Resumo: | Introduction: stretch marks are multifactorial unsightly conditions and for their treatment, resources are needed to stimulate a new process of tissue repair and regeneration. Objective: to evaluate the efficacy and safety of carboxitherapy associated with high volt current in the treatment of atrophic stretch marks. Method: This is a clinical, longitudinal, blind, prospective and comparative study, in which women with atrophic stretch marks were selected, they were evaluated and reassessed in the interval of 5 and at the end of the 10 treatment sessions. The evaluation consisted of the classification of the skin phototype using the Fitzpatrick’s Scale, analysis of the length and width of the atrophic streak, evaluation of the skin viscoelasticity with Cutometer® and photographic analysis. The treatment consisted of the application of carboxitherapy associated with the high volt current. Tukey's ANOVA and post hoc tests (p≤0.05) were performed to evaluate the results. Results: there was a decrease in the thickness of the streaks of the right gluteus between the initial assessment and 5 sessions and the initial one for 10 sessions, with respective p <0.01, whereas in the left gluteus we observed a decrease between the initial assessment and 5 sessions and the initial one for 10 sessions, with p <0.05 in both. In the Cutometer® analysis, there was a significance of p <0.01 in the variables R0, R2, R6 and R8, showing an improvement in the viscoelastic properties of the atrophic stria when compared to the initial evaluation with 10 treatment sessions. Conclusion: the association of carboxitherapy with the high volt current was effective in decreasing the thickness of the atrophic streaks in glutes and in improving the viscoelastic properties of the skin. |
id |
UNIFEI_4e6b0a434791448cdd0d70e8ebd36593 |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/10430 |
network_acronym_str |
UNIFEI |
network_name_str |
Research, Society and Development |
repository_id_str |
|
spelling |
Efficacy and safety of Carboxitherapy associated with High Volt current in the treatment of atrophic stretch marks on glutesEficacia y seguridad de la Carboxiterapia asociada a la corriente de Alto Voltaje en el tratamiento de estrías atróficas en glúteosEficácia e segurança da Carboxiterapia associada a corrente High Volt no tratamento de estrias atróficas em glúteosEstrias de distensãoElasticidadeEstimulação elétricaPeleFibroblastos.EstríasElasticidadEstimulación eléctricaPielFibroblastos.Stretch marks ElasticityElectrical stimulationSkinFibroblasts.Introduction: stretch marks are multifactorial unsightly conditions and for their treatment, resources are needed to stimulate a new process of tissue repair and regeneration. Objective: to evaluate the efficacy and safety of carboxitherapy associated with high volt current in the treatment of atrophic stretch marks. Method: This is a clinical, longitudinal, blind, prospective and comparative study, in which women with atrophic stretch marks were selected, they were evaluated and reassessed in the interval of 5 and at the end of the 10 treatment sessions. The evaluation consisted of the classification of the skin phototype using the Fitzpatrick’s Scale, analysis of the length and width of the atrophic streak, evaluation of the skin viscoelasticity with Cutometer® and photographic analysis. The treatment consisted of the application of carboxitherapy associated with the high volt current. Tukey's ANOVA and post hoc tests (p≤0.05) were performed to evaluate the results. Results: there was a decrease in the thickness of the streaks of the right gluteus between the initial assessment and 5 sessions and the initial one for 10 sessions, with respective p <0.01, whereas in the left gluteus we observed a decrease between the initial assessment and 5 sessions and the initial one for 10 sessions, with p <0.05 in both. In the Cutometer® analysis, there was a significance of p <0.01 in the variables R0, R2, R6 and R8, showing an improvement in the viscoelastic properties of the atrophic stria when compared to the initial evaluation with 10 treatment sessions. Conclusion: the association of carboxitherapy with the high volt current was effective in decreasing the thickness of the atrophic streaks in glutes and in improving the viscoelastic properties of the skin.Introducción: las estrías son afecciones multifactoriales antiestéticas y para su tratamiento se necesitan recursos que estimulen un nuevo proceso de reparación y regeneración tisular. Objetivo: evaluar la eficacia y seguridad de la carboxiterapia asociada a la corriente de alto voltaje en el tratamiento de estrías atróficas. Método: Se trata de un estudio clínico, longitudinal, ciego, prospectivo y comparativo, en el que se seleccionaron mujeres con estrías atróficas, se evaluaron y reevaluaron en el intervalo de 5 y al final de las 10 sesiones de tratamiento. La evaluación consistió en la clasificación del fototipo de piel mediante la Escala de Fitzpatrick, análisis del largo y ancho de la veta atrófica, evaluación de la viscoelasticidad de la piel con Cutometer® y análisis fotográfico. El tratamiento consistió en la aplicación de carboxiterapia asociada a la corriente de alto voltaje. Se realizaron ANOVA de Tukey y pruebas post hoc (p≤0.05) para evaluar los resultados. Resultados: hubo una disminución en el grosor de las estrías del glúteo derecho entre la evaluación inicial y 5 sesiones y la inicial para 10 sesiones, con p <0.01 respectivo, mientras que en el glúteo izquierdo observamos una disminución entre la evaluación inicial y 5 sesiones y la inicial para 10 sesiones, con p <0.05 en ambos. En el análisis de Cutometer® hubo una significancia de p <0.01 en las variables R0, R2, R6 y R8, mostrando una mejora en las propiedades viscoelásticas de la estría atrófica al compararla con la evaluación inicial con 10 sesiones de tratamiento. Conclusión: la asociación de la carboxiterapia con la corriente de alto voltaje fue efectiva para disminuir el grosor de las estrías atróficas en glúteos y mejorar las propiedades viscoelásticas de la piel.Introdução: estrias são afecções inestéticas multifatoriais e para seu tratamento são necessários recursos que estimulem um novo processo de reparo e regeneração tecidual. Objetivo: avaliar a eficácia e segurança da carboxiterapia associada a corrente high volt no tratamento de estrias atróficas. Método: Trata-se de um estudo clínico, longitudinal, cego, prospectivo e comparativo, onde mulheres com estrias atróficas em foram selecionadas, as mesmas foram avaliadas e reavaliadas no intervalo de 5 e ao final das 10 sessões de tratamento. A avaliação foi composta pela classificação do fototipo de pele por meio da Escala de Fitzpatrick’s, análise do comprimento e largura da estria atrófica, avaliação da viscoelasticidade da pele com Cutometer® e analise fotográfica. O tratamento foi composto pela aplicação de carboxiterapia associado com a corrente high volt. Para avaliação dos resultados foram realizados os testes ANOVA e post hoc de Tukey (p≤0.05). Resultados: houve diminuição da espessura das estrias do glúteo direito entre a avaliação inicial e 5 sessões e inicial para 10 sessões, com respectivos p<0.01, já no glúteo esquerdo observamos a diminuição entre a avaliação inicial e 5 sessões e inicial para 10 sessões, com p<0.05 em ambos. Na análise do Cutometer® houve significância de p<0.01 nas variáveis R0, R2, R6 e R8, demostrando melhora nas propriedades viscoelásticas das estrias atróficas quando comparado a avaliação inicial com 10 sessões de tratamento. Conclusão: a associação da carboxiterapia com a corrente high volt foi eficaz na diminuição da espessura das estrias atróficas em glúteos e na melhora das propriedades viscoelásticas da pele.Research, Society and Development2020-12-05info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1043010.33448/rsd-v9i11.10430Research, Society and Development; Vol. 9 No. 11; e85491110430Research, Society and Development; Vol. 9 Núm. 11; e85491110430Research, Society and Development; v. 9 n. 11; e854911104302525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/10430/9420Copyright (c) 2020 Stephani de Almeida; Caroline Nogueira da Silva; Renata Gomes Moreira; Renata Michelini Guidi; Clovis Grecco ; José Ricardo de Souza; Debora Aparecida Oliveira Modenahttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessAlmeida, Stephani deSilva, Caroline Nogueira da Moreira, Renata Gomes Guidi, Renata Michelini Grecco , Clovis Souza, José Ricardo de Modena, Debora Aparecida Oliveira 2020-12-10T23:37:57Zoai:ojs.pkp.sfu.ca:article/10430Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:32:29.192239Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false |
dc.title.none.fl_str_mv |
Efficacy and safety of Carboxitherapy associated with High Volt current in the treatment of atrophic stretch marks on glutes Eficacia y seguridad de la Carboxiterapia asociada a la corriente de Alto Voltaje en el tratamiento de estrías atróficas en glúteos Eficácia e segurança da Carboxiterapia associada a corrente High Volt no tratamento de estrias atróficas em glúteos |
title |
Efficacy and safety of Carboxitherapy associated with High Volt current in the treatment of atrophic stretch marks on glutes |
spellingShingle |
Efficacy and safety of Carboxitherapy associated with High Volt current in the treatment of atrophic stretch marks on glutes Almeida, Stephani de Estrias de distensão Elasticidade Estimulação elétrica Pele Fibroblastos. Estrías Elasticidad Estimulación eléctrica Piel Fibroblastos. Stretch marks Elasticity Electrical stimulation Skin Fibroblasts. |
title_short |
Efficacy and safety of Carboxitherapy associated with High Volt current in the treatment of atrophic stretch marks on glutes |
title_full |
Efficacy and safety of Carboxitherapy associated with High Volt current in the treatment of atrophic stretch marks on glutes |
title_fullStr |
Efficacy and safety of Carboxitherapy associated with High Volt current in the treatment of atrophic stretch marks on glutes |
title_full_unstemmed |
Efficacy and safety of Carboxitherapy associated with High Volt current in the treatment of atrophic stretch marks on glutes |
title_sort |
Efficacy and safety of Carboxitherapy associated with High Volt current in the treatment of atrophic stretch marks on glutes |
author |
Almeida, Stephani de |
author_facet |
Almeida, Stephani de Silva, Caroline Nogueira da Moreira, Renata Gomes Guidi, Renata Michelini Grecco , Clovis Souza, José Ricardo de Modena, Debora Aparecida Oliveira |
author_role |
author |
author2 |
Silva, Caroline Nogueira da Moreira, Renata Gomes Guidi, Renata Michelini Grecco , Clovis Souza, José Ricardo de Modena, Debora Aparecida Oliveira |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Almeida, Stephani de Silva, Caroline Nogueira da Moreira, Renata Gomes Guidi, Renata Michelini Grecco , Clovis Souza, José Ricardo de Modena, Debora Aparecida Oliveira |
dc.subject.por.fl_str_mv |
Estrias de distensão Elasticidade Estimulação elétrica Pele Fibroblastos. Estrías Elasticidad Estimulación eléctrica Piel Fibroblastos. Stretch marks Elasticity Electrical stimulation Skin Fibroblasts. |
topic |
Estrias de distensão Elasticidade Estimulação elétrica Pele Fibroblastos. Estrías Elasticidad Estimulación eléctrica Piel Fibroblastos. Stretch marks Elasticity Electrical stimulation Skin Fibroblasts. |
description |
Introduction: stretch marks are multifactorial unsightly conditions and for their treatment, resources are needed to stimulate a new process of tissue repair and regeneration. Objective: to evaluate the efficacy and safety of carboxitherapy associated with high volt current in the treatment of atrophic stretch marks. Method: This is a clinical, longitudinal, blind, prospective and comparative study, in which women with atrophic stretch marks were selected, they were evaluated and reassessed in the interval of 5 and at the end of the 10 treatment sessions. The evaluation consisted of the classification of the skin phototype using the Fitzpatrick’s Scale, analysis of the length and width of the atrophic streak, evaluation of the skin viscoelasticity with Cutometer® and photographic analysis. The treatment consisted of the application of carboxitherapy associated with the high volt current. Tukey's ANOVA and post hoc tests (p≤0.05) were performed to evaluate the results. Results: there was a decrease in the thickness of the streaks of the right gluteus between the initial assessment and 5 sessions and the initial one for 10 sessions, with respective p <0.01, whereas in the left gluteus we observed a decrease between the initial assessment and 5 sessions and the initial one for 10 sessions, with p <0.05 in both. In the Cutometer® analysis, there was a significance of p <0.01 in the variables R0, R2, R6 and R8, showing an improvement in the viscoelastic properties of the atrophic stria when compared to the initial evaluation with 10 treatment sessions. Conclusion: the association of carboxitherapy with the high volt current was effective in decreasing the thickness of the atrophic streaks in glutes and in improving the viscoelastic properties of the skin. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-12-05 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://rsdjournal.org/index.php/rsd/article/view/10430 10.33448/rsd-v9i11.10430 |
url |
https://rsdjournal.org/index.php/rsd/article/view/10430 |
identifier_str_mv |
10.33448/rsd-v9i11.10430 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://rsdjournal.org/index.php/rsd/article/view/10430/9420 |
dc.rights.driver.fl_str_mv |
https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Research, Society and Development |
publisher.none.fl_str_mv |
Research, Society and Development |
dc.source.none.fl_str_mv |
Research, Society and Development; Vol. 9 No. 11; e85491110430 Research, Society and Development; Vol. 9 Núm. 11; e85491110430 Research, Society and Development; v. 9 n. 11; e85491110430 2525-3409 reponame:Research, Society and Development instname:Universidade Federal de Itajubá (UNIFEI) instacron:UNIFEI |
instname_str |
Universidade Federal de Itajubá (UNIFEI) |
instacron_str |
UNIFEI |
institution |
UNIFEI |
reponame_str |
Research, Society and Development |
collection |
Research, Society and Development |
repository.name.fl_str_mv |
Research, Society and Development - Universidade Federal de Itajubá (UNIFEI) |
repository.mail.fl_str_mv |
rsd.articles@gmail.com |
_version_ |
1797052804485873664 |