Evaluation of efficiency of different coagulants used in water treatment plant

Detalhes bibliográficos
Autor(a) principal: Souza, Cristiane Daliassi Ramos de
Data de Publicação: 2021
Outros Autores: Ferreira, Iago Bruno Pacheco
Tipo de documento: Artigo
Idioma: por
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/21127
Resumo: In Amazon region is located one of the largest reserves of fresh water in the world, where there is often the paradox that in many riverside cities, the population is not provided with treated and quality water. The Solimões River is one of the largest rivers today, where many people reside along its passage. The objective of this work was to evaluate the coagulant action of three commercial products (Aluminum Sulfate, Ferric Chloride and Polyaluminium Chloride) for use in the Water Treatment Plant of Careiro da Várzea. The methodology was divided into three stages, starting with the monitoring of physico-chemical and bacteriological analyzes of the water source at the water catchment site. Then, bench tests were carried out using Jar Test with concentrations from 7 to 25 ppm, for each coagulant, to verify the optimal characteristics of the process. Finally, the tests were carried out at the city's WTP for 24 hours and the parameters of turbidity and color were monitored. The results showed that the source presented basic characteristics, with high turbidity and color. In laboratory tests, as well as in the scale-up, it was found that the commercial coagulant, ferric chloride, presented better efficiency at 20 ppm with WTP operating conditions of 0.2 ppm flocculant and pH 7.
id UNIFEI_9101b0f868a59977d7fabdeb6242a788
oai_identifier_str oai:ojs.pkp.sfu.ca:article/21127
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Evaluation of efficiency of different coagulants used in water treatment plantEvaluación de la eficiencia de diferentes coagulantes utilizados en la planta de tratamiento de aguaAvaliação da eficiência de diferentes coagulantes utilizados em uma Estação de Tratamento de ÁguasRio SolimõesEstação de Tratamento de ÁguasCoagulantesJar Test.Río SolimõesPlanta de tratamiento de aguaCoagulantesJar Test.Solimões RiverWater Treatment PlantCoagulantsJar Test.In Amazon region is located one of the largest reserves of fresh water in the world, where there is often the paradox that in many riverside cities, the population is not provided with treated and quality water. The Solimões River is one of the largest rivers today, where many people reside along its passage. The objective of this work was to evaluate the coagulant action of three commercial products (Aluminum Sulfate, Ferric Chloride and Polyaluminium Chloride) for use in the Water Treatment Plant of Careiro da Várzea. The methodology was divided into three stages, starting with the monitoring of physico-chemical and bacteriological analyzes of the water source at the water catchment site. Then, bench tests were carried out using Jar Test with concentrations from 7 to 25 ppm, for each coagulant, to verify the optimal characteristics of the process. Finally, the tests were carried out at the city's WTP for 24 hours and the parameters of turbidity and color were monitored. The results showed that the source presented basic characteristics, with high turbidity and color. In laboratory tests, as well as in the scale-up, it was found that the commercial coagulant, ferric chloride, presented better efficiency at 20 ppm with WTP operating conditions of 0.2 ppm flocculant and pH 7.En la región amazónica se encuentra una de las mayores reservas de agua dulce del mundo, donde suele darse la paradoja de que en muchas ciudades ribereñas la población no cuenta con agua tratada y de calidad. El río Solimões es uno de los ríos más grandes de la actualidad, donde residen muchas personas a lo largo de su paso. El objetivo de este trabajo fue evaluar la acción coagulante de tres productos comerciales (Sulfato de Aluminio, Cloruro Férrico y Cloruro de Polialuminio) para su uso en la Planta de Tratamiento de Agua de Careiro da Várzea. La metodología se dividió en tres etapas, comenzando con el seguimiento de los análisis fisicoquímicos y bacteriológicos de la fuente de agua en el sitio de captación de agua. Luego, se realizaron pruebas de banco utilizando Jar Test con concentraciones de 7 a 25 ppm, para cada coagulante, para verificar las características óptimas del proceso. Finalmente, las pruebas se realizaron en la ETA de la ciudad durante 24 horas y se monitorearon los parámetros de turbidez y color. Los resultados mostraron que la fuente presenta características básicas, con alta turbidez y color. En las pruebas de laboratorio, así como en el escalado, se encontró que el coagulante comercial, el cloruro férrico, mostró una mejor eficiencia a 20 ppm con condiciones de operación ETA de 0,2 ppm de floculante y pH 7.Na região Amazônica situa-se uma das maiores reservas de água doce do mundo, onde muitas vezes existe o paradoxo de que em muitas cidades ribeirinhas, a população não é comtemplada com água tratada e de qualidade. O Rio Solimões é um dos maiores rios atualmente, onde muitas pessoas residem ao longo de sua passagem. O objetivo deste trabalho foi avaliar a ação coagulante de três produtos comerciais (Sulfato de Alumínio, Cloreto Férrico e Policloreto de Alumínio) para utilização na Estação de Tratamento de Águas do Careiro da Várzea. A metodologia foi dividida em três etapas, iniciou-se com o monitoramento das análises físico-químicas e bacteriológicas do manancial no local de captação das águas. Em seguida foram realizados ensaios de bancada utilizando Jar Test com concentrações de 7 a 25 ppm, para cada coagulante, para verificar as características ótimas do processo. Por fim, executaram-se os testes na ETA da cidade durante 24 horas e foram monitorados os parâmetros de turbidez e cor. Os resultados mostraram que o manancial apresentou características básicas, com alta turbidez e cor. Nos ensaios laboratoriais, assim como no aumento de escala constatou-se que o coagulante comercial, cloreto férrico, apresentou uma melhor eficiência a 20 ppm com condições operacionais na ETA de 0,2 ppm de floculante e pH 7.Research, Society and Development2021-10-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/2112710.33448/rsd-v10i13.21127Research, Society and Development; Vol. 10 No. 13; e284101321127Research, Society and Development; Vol. 10 Núm. 13; e284101321127Research, Society and Development; v. 10 n. 13; e2841013211272525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/21127/18930Copyright (c) 2021 Cristiane Daliassi Ramos de Souza; Iago Bruno Pacheco Ferreirahttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessSouza, Cristiane Daliassi Ramos deFerreira, Iago Bruno Pacheco2021-11-21T18:26:28Zoai:ojs.pkp.sfu.ca:article/21127Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:40:36.644489Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Evaluation of efficiency of different coagulants used in water treatment plant
Evaluación de la eficiencia de diferentes coagulantes utilizados en la planta de tratamiento de agua
Avaliação da eficiência de diferentes coagulantes utilizados em uma Estação de Tratamento de Águas
title Evaluation of efficiency of different coagulants used in water treatment plant
spellingShingle Evaluation of efficiency of different coagulants used in water treatment plant
Souza, Cristiane Daliassi Ramos de
Rio Solimões
Estação de Tratamento de Águas
Coagulantes
Jar Test.
Río Solimões
Planta de tratamiento de agua
Coagulantes
Jar Test.
Solimões River
Water Treatment Plant
Coagulants
Jar Test.
title_short Evaluation of efficiency of different coagulants used in water treatment plant
title_full Evaluation of efficiency of different coagulants used in water treatment plant
title_fullStr Evaluation of efficiency of different coagulants used in water treatment plant
title_full_unstemmed Evaluation of efficiency of different coagulants used in water treatment plant
title_sort Evaluation of efficiency of different coagulants used in water treatment plant
author Souza, Cristiane Daliassi Ramos de
author_facet Souza, Cristiane Daliassi Ramos de
Ferreira, Iago Bruno Pacheco
author_role author
author2 Ferreira, Iago Bruno Pacheco
author2_role author
dc.contributor.author.fl_str_mv Souza, Cristiane Daliassi Ramos de
Ferreira, Iago Bruno Pacheco
dc.subject.por.fl_str_mv Rio Solimões
Estação de Tratamento de Águas
Coagulantes
Jar Test.
Río Solimões
Planta de tratamiento de agua
Coagulantes
Jar Test.
Solimões River
Water Treatment Plant
Coagulants
Jar Test.
topic Rio Solimões
Estação de Tratamento de Águas
Coagulantes
Jar Test.
Río Solimões
Planta de tratamiento de agua
Coagulantes
Jar Test.
Solimões River
Water Treatment Plant
Coagulants
Jar Test.
description In Amazon region is located one of the largest reserves of fresh water in the world, where there is often the paradox that in many riverside cities, the population is not provided with treated and quality water. The Solimões River is one of the largest rivers today, where many people reside along its passage. The objective of this work was to evaluate the coagulant action of three commercial products (Aluminum Sulfate, Ferric Chloride and Polyaluminium Chloride) for use in the Water Treatment Plant of Careiro da Várzea. The methodology was divided into three stages, starting with the monitoring of physico-chemical and bacteriological analyzes of the water source at the water catchment site. Then, bench tests were carried out using Jar Test with concentrations from 7 to 25 ppm, for each coagulant, to verify the optimal characteristics of the process. Finally, the tests were carried out at the city's WTP for 24 hours and the parameters of turbidity and color were monitored. The results showed that the source presented basic characteristics, with high turbidity and color. In laboratory tests, as well as in the scale-up, it was found that the commercial coagulant, ferric chloride, presented better efficiency at 20 ppm with WTP operating conditions of 0.2 ppm flocculant and pH 7.
publishDate 2021
dc.date.none.fl_str_mv 2021-10-12
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/21127
10.33448/rsd-v10i13.21127
url https://rsdjournal.org/index.php/rsd/article/view/21127
identifier_str_mv 10.33448/rsd-v10i13.21127
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/21127/18930
dc.rights.driver.fl_str_mv Copyright (c) 2021 Cristiane Daliassi Ramos de Souza; Iago Bruno Pacheco Ferreira
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2021 Cristiane Daliassi Ramos de Souza; Iago Bruno Pacheco Ferreira
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 10 No. 13; e284101321127
Research, Society and Development; Vol. 10 Núm. 13; e284101321127
Research, Society and Development; v. 10 n. 13; e284101321127
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052691883491328