Performance of a photovoltaic panel (PV) converted to a thermal photovoltaic with collector for hot water (PVT/w)

Detalhes bibliográficos
Autor(a) principal: Jordan, Rodrigo Aparecido
Data de Publicação: 2021
Outros Autores: Moreira Junior, Orlando, Antunes, Bruno Machado, Motomiya, Anamari Viegas de Araujo, Sanches, Ítalo Sabião, Sanches, Édipo Sabião, Omido, Agleison Ramos, Martins, Elton Aparecido Siqueira
Tipo de documento: Artigo
Idioma: por
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/16438
Resumo: Tests were carried out in an open environment with two photovoltaic panels, in the city of Dourados/MS, for six non-consecutive days, between the months of June to July 2018, where one panel was kept original (PV), while the other underwent modifications to operate as a photovoltaic-thermal module using (PVT/w), which is connected to a reservoir for hot water accumulation. The tests were carried out according to the open circuit voltage (Voc), the surface temperature of the photovoltaic cells and the water temperature of the cooling and thermoaccumulation system of the PVT/w, to determine the adequate and adequate thermal energy of the thermal yield. The increase in the temperature of the cooling water negatively affects the value of the open circuit voltage, which was, on average, 2.3% higher for PVT/w, which presented a lower surface temperature in all tests. The average thermal efficiency of PVT/w was 242 W m-2, given in an estimate of total efficiency (thermal and electrical) of 349 W m-2, an increase of 161% in relation to the energy efficiency of PV (only electricity), estimated at 106 W m-2 based on information from the manufacturer's technical catalog.
id UNIFEI_e2b187b3ef919fdbd0ac841dfb03c7a8
oai_identifier_str oai:ojs.pkp.sfu.ca:article/16438
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling Performance of a photovoltaic panel (PV) converted to a thermal photovoltaic with collector for hot water (PVT/w)Rendimiento de un panel fotovoltaico (PV) convertido en fotovoltaico térmico con colector de agua caliente (PVT/w)Desempenho de um painel fotovoltaico (PV) convertido em um fotovoltaico térmico com coletor para água quente (PVT/w)Solar energyThermal and electric energyEnergy efficiency.Energía solarEnergía térmica y eléctricaEficiencia energética.Energia solarEnergia térmica e elétricaRendimento energético.Tests were carried out in an open environment with two photovoltaic panels, in the city of Dourados/MS, for six non-consecutive days, between the months of June to July 2018, where one panel was kept original (PV), while the other underwent modifications to operate as a photovoltaic-thermal module using (PVT/w), which is connected to a reservoir for hot water accumulation. The tests were carried out according to the open circuit voltage (Voc), the surface temperature of the photovoltaic cells and the water temperature of the cooling and thermoaccumulation system of the PVT/w, to determine the adequate and adequate thermal energy of the thermal yield. The increase in the temperature of the cooling water negatively affects the value of the open circuit voltage, which was, on average, 2.3% higher for PVT/w, which presented a lower surface temperature in all tests. The average thermal efficiency of PVT/w was 242 W m-2, given in an estimate of total efficiency (thermal and electrical) of 349 W m-2, an increase of 161% in relation to the energy efficiency of PV (only electricity), estimated at 106 W m-2 based on information from the manufacturer's technical catalog.Las pruebas se realizaron en un ambiente abierto con dos paneles fotovoltaicos, en la ciudad de Dourados / MS, durante seis días no consecutivos, entre los meses de junio a julio de 2018, donde un panel se mantuvo original (PV), mientras que el otro se sometió a modificaciones para funcionar como módulo fotovoltaico-térmico utilizando (PVT / w), que se conecta a un depósito para la acumulación de agua caliente. Las pruebas se realizaron en función de la tensión en circuito abierto (Voc), la temperatura superficial de las células fotovoltaicas y la temperatura del agua del sistema de refrigeración y termoacumulación del PVT / w, para determinar la energía térmica adecuada y adecuada del rendimiento térmico. El aumento de la temperatura del agua de refrigeración incide negativamente en el valor de la tensión de circuito abierto, que fue, en promedio, un 2,3% superior para PVT / w, que presentó una temperatura superficial más baja en todas las pruebas. La eficiencia térmica promedio de PVT / w fue de 242 W m-2, dada en una estimación de eficiencia total (térmica y eléctrica) de 349 W m-2, un aumento del 161% en relación a la eficiencia energética de PV (solo electricidad), estimado en 106 W m-2 según información del catálogo técnico del fabricante.  Foram realizados testes em ambiente aberto com dois painéis fotovoltaicos, na cidade de Dourados/MS, durante seis dias não consecutivos, entre os meses de junho a julho de 2018, onde um painel foi mantido original (PV), enquanto o outro sofreu modificações para operar como um módulo fotovoltaico-térmico utilizando água (PVT/w), sendo este conectado a um reservatório para acumulação de água quente. Nos ensaios foram feitas medições de tensão de circuito aberto (Voc), temperatura na superfície das células fotovoltaicas e temperatura da água do sistema de resfriamento e termoacumulação do PVT/w, para determinação da energia térmica produzida e estimativa do rendimento térmico. O aumento da temperatura da água de arrefecimento afeta de forma negativa o valor da tensão de circuito aberto, a qual foi, em média, 2,3% maior para o PVT/w, o qual apresentou menor temperatura superficial em todos os testes. O rendimento térmico médio do PVT/w foi de 242 W m-2, resultando numa estimativa de rendimento total (térmico e elétrico) de 349 W m-2, um aumento de 161% em relação ao rendimento energético do PV (apenas energia elétrica), estimada em 106 W m-2 com base nas informações do catálogo técnico do fabricante.Research, Society and Development2021-07-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/1643810.33448/rsd-v10i7.16438Research, Society and Development; Vol. 10 No. 7; e14210716438Research, Society and Development; Vol. 10 Núm. 7; e14210716438Research, Society and Development; v. 10 n. 7; e142107164382525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIporhttps://rsdjournal.org/index.php/rsd/article/view/16438/15161Copyright (c) 2021 Rodrigo Aparecido Jordan; Orlando Moreira Junior; Bruno Machado Antunes; Anamari Viegas de Araujo Motomiya; Ítalo Sabião Sanches; Édipo Sabião Sanches; Agleison Ramos Omido; Elton Aparecido Siqueira Martinshttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessJordan, Rodrigo AparecidoMoreira Junior, Orlando Antunes, Bruno MachadoMotomiya, Anamari Viegas de Araujo Sanches, Ítalo SabiãoSanches, Édipo Sabião Omido, Agleison Ramos Martins, Elton Aparecido Siqueira 2021-07-18T21:07:03Zoai:ojs.pkp.sfu.ca:article/16438Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:36:59.320304Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Performance of a photovoltaic panel (PV) converted to a thermal photovoltaic with collector for hot water (PVT/w)
Rendimiento de un panel fotovoltaico (PV) convertido en fotovoltaico térmico con colector de agua caliente (PVT/w)
Desempenho de um painel fotovoltaico (PV) convertido em um fotovoltaico térmico com coletor para água quente (PVT/w)
title Performance of a photovoltaic panel (PV) converted to a thermal photovoltaic with collector for hot water (PVT/w)
spellingShingle Performance of a photovoltaic panel (PV) converted to a thermal photovoltaic with collector for hot water (PVT/w)
Jordan, Rodrigo Aparecido
Solar energy
Thermal and electric energy
Energy efficiency.
Energía solar
Energía térmica y eléctrica
Eficiencia energética.
Energia solar
Energia térmica e elétrica
Rendimento energético.
title_short Performance of a photovoltaic panel (PV) converted to a thermal photovoltaic with collector for hot water (PVT/w)
title_full Performance of a photovoltaic panel (PV) converted to a thermal photovoltaic with collector for hot water (PVT/w)
title_fullStr Performance of a photovoltaic panel (PV) converted to a thermal photovoltaic with collector for hot water (PVT/w)
title_full_unstemmed Performance of a photovoltaic panel (PV) converted to a thermal photovoltaic with collector for hot water (PVT/w)
title_sort Performance of a photovoltaic panel (PV) converted to a thermal photovoltaic with collector for hot water (PVT/w)
author Jordan, Rodrigo Aparecido
author_facet Jordan, Rodrigo Aparecido
Moreira Junior, Orlando
Antunes, Bruno Machado
Motomiya, Anamari Viegas de Araujo
Sanches, Ítalo Sabião
Sanches, Édipo Sabião
Omido, Agleison Ramos
Martins, Elton Aparecido Siqueira
author_role author
author2 Moreira Junior, Orlando
Antunes, Bruno Machado
Motomiya, Anamari Viegas de Araujo
Sanches, Ítalo Sabião
Sanches, Édipo Sabião
Omido, Agleison Ramos
Martins, Elton Aparecido Siqueira
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Jordan, Rodrigo Aparecido
Moreira Junior, Orlando
Antunes, Bruno Machado
Motomiya, Anamari Viegas de Araujo
Sanches, Ítalo Sabião
Sanches, Édipo Sabião
Omido, Agleison Ramos
Martins, Elton Aparecido Siqueira
dc.subject.por.fl_str_mv Solar energy
Thermal and electric energy
Energy efficiency.
Energía solar
Energía térmica y eléctrica
Eficiencia energética.
Energia solar
Energia térmica e elétrica
Rendimento energético.
topic Solar energy
Thermal and electric energy
Energy efficiency.
Energía solar
Energía térmica y eléctrica
Eficiencia energética.
Energia solar
Energia térmica e elétrica
Rendimento energético.
description Tests were carried out in an open environment with two photovoltaic panels, in the city of Dourados/MS, for six non-consecutive days, between the months of June to July 2018, where one panel was kept original (PV), while the other underwent modifications to operate as a photovoltaic-thermal module using (PVT/w), which is connected to a reservoir for hot water accumulation. The tests were carried out according to the open circuit voltage (Voc), the surface temperature of the photovoltaic cells and the water temperature of the cooling and thermoaccumulation system of the PVT/w, to determine the adequate and adequate thermal energy of the thermal yield. The increase in the temperature of the cooling water negatively affects the value of the open circuit voltage, which was, on average, 2.3% higher for PVT/w, which presented a lower surface temperature in all tests. The average thermal efficiency of PVT/w was 242 W m-2, given in an estimate of total efficiency (thermal and electrical) of 349 W m-2, an increase of 161% in relation to the energy efficiency of PV (only electricity), estimated at 106 W m-2 based on information from the manufacturer's technical catalog.
publishDate 2021
dc.date.none.fl_str_mv 2021-07-04
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/16438
10.33448/rsd-v10i7.16438
url https://rsdjournal.org/index.php/rsd/article/view/16438
identifier_str_mv 10.33448/rsd-v10i7.16438
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/16438/15161
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 10 No. 7; e14210716438
Research, Society and Development; Vol. 10 Núm. 7; e14210716438
Research, Society and Development; v. 10 n. 7; e14210716438
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052750677147648