Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults

Detalhes bibliográficos
Autor(a) principal: Correa, Rafaéle Gomes
Data de Publicação: 2022
Outros Autores: Silva, Rubens Alexandre da, Guariglia , Débora Alvez, Stocco, Marieli Ramos, Oliveira , Márcio Rogério de, Andraus, Rodrigo Antônio Carvalho
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Research, Society and Development
DOI: 10.33448/rsd-v11i1.24198
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/24198
Resumo: The objective of this study was to verify the effect of kinesio-taping (KT) application of the origin for muscle insertion (O>I) and insertion for muscle origin (I>O) in healthy participants, through surface electromyography and peak torque of gastrocnemius muscles. A total of 69 participants with an average age of 22.9±5.2 years were evaluated, 41 women with an average age of 22.0±5.1 years, BMI 25.1±4.6 kg/m2, and 28 men with an average age of 22.0±5.1 years, BMI 23.1±3.3 kg/m2, randomized under three conditions: O>I, I>O and no KT (control), repeated three times with five-minute rest between sessions. The peak torque of the gastrocnemius lateral (GML) and medial (GMM) muscles was evaluated at speeds 30º/s 60º/s 120º/s and muscle activity through surface electromyography. Repeated-measurement ANOVA showed effect only on the variable speed (F=767,1; p<0.001) and the variables condition (F=0.010; p=0.990) and interaction (F=0.199; p=0.892) were not significant. In electromyography, Root mean Square (RMS) did not differ in the conditions evaluated, presenting standard behavior without significant differences. The KT application regardless of being O>I or I>O muscular, did not alter the muscle recruitment or contribute to the increase in peak torque performance during the three speeds.
id UNIFEI_e70de09a68a3e16002d77283bd2bb127
oai_identifier_str oai:ojs.pkp.sfu.ca:article/24198
network_acronym_str UNIFEI
network_name_str Research, Society and Development
spelling Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adultsEfecto del método de aplicación kinesio-taping para la activación y resistencia de músculos gastrocnemios en adultos sanosEfeito do método de aplicação da kinesio taping na ativação e força do músculos gastrocnêmicos em adultos saudáveisDinamômetro de Força MuscularEletromiografiaFita AtléticaForça MuscularTorque.ElectromyographyMuscle Strength DynamometerMuscle StrengthAthletic tapeTorque.Cinta AtléticaDinamómetro de Fuerza MusculaElectromiografíaFuerza musculaTorque.The objective of this study was to verify the effect of kinesio-taping (KT) application of the origin for muscle insertion (O>I) and insertion for muscle origin (I>O) in healthy participants, through surface electromyography and peak torque of gastrocnemius muscles. A total of 69 participants with an average age of 22.9±5.2 years were evaluated, 41 women with an average age of 22.0±5.1 years, BMI 25.1±4.6 kg/m2, and 28 men with an average age of 22.0±5.1 years, BMI 23.1±3.3 kg/m2, randomized under three conditions: O>I, I>O and no KT (control), repeated three times with five-minute rest between sessions. The peak torque of the gastrocnemius lateral (GML) and medial (GMM) muscles was evaluated at speeds 30º/s 60º/s 120º/s and muscle activity through surface electromyography. Repeated-measurement ANOVA showed effect only on the variable speed (F=767,1; p<0.001) and the variables condition (F=0.010; p=0.990) and interaction (F=0.199; p=0.892) were not significant. In electromyography, Root mean Square (RMS) did not differ in the conditions evaluated, presenting standard behavior without significant differences. The KT application regardless of being O>I or I>O muscular, did not alter the muscle recruitment or contribute to the increase in peak torque performance during the three speeds.El objetivo de este estudio fue verificar el efecto de la aplicación de kinesio-taping (KT) del origen para la inserción muscular (O>I) y la inserción del origen muscular (I>O) en participantes sanos, mediante electromiografía de superficie y torque pico de músculos gastrocnemio. Se evaluaron un total de 69 participantes con una edad promedio de 22,9±5,2 años, 41 mujeres con una edad media de 22,0±5,1 años, IMC 25,1±4,6 kg/m2 y 28 hombres con una edad media de 22,0±5,1 años. IMC 23,1±3,3 kg/m2, aleatorizado en tres condiciones: O>I, I>O y sin KT (control), repetido tres veces con cinco minutos de descanso entre sesiones. El torque máximo de los músculos gastrocnemio lateral (GML) y medial (GMM) se evaluó a velocidades de 30º/s 60º/s 120º/s y actividad muscular mediante electromiografía de superficie. El ANOVA de medición repetida mostró efecto solo en la variable velocidad (F=767,1; p<0.001) y las variables condición (F=0.010; p=0.990) e interacción (F=0.199; p=0.892) no fueron significativas. En electromiografía, Root mean Square (RMS) no difirió en las condiciones evaluadas, presentando comportamiento estándar sin diferencias significativas. La aplicación de KT, independientemente de ser O>I o I>O muscular, no alteró el reclutamiento muscular ni contribuyó al aumento del rendimiento de torque máximo durante las tres velocidades.O objetivo deste estudo foi verificar o efeito da aplicação de kinesio-taping (KT) da origem para inserção muscular (O>I) e da inserção para origem muscular (I>O) em participantes saudáveis, por meio de eletromiografia de superfície e pico de torque de músculos gastrocnêmios. Foram avaliados 69 participantes com idade média de 22,9±5,2 anos, 41 mulheres com idade média de 22,0±5,1 anos, IMC 25,1±4,6 kg/m2 e 28 homens com idade média de 22,0±5,1 anos, IMC 23,1±3,3 kg/m2, randomizado em três condições: O>I, I>O e sem KT (controle), repetido três vezes com cinco minutos de repouso entre as sessões. O pico de torque dos músculos gastrocnêmio lateral (GML) e medial (GMM) foi avaliado nas velocidades 30/s 60/s 120/s e atividade muscular por meio da eletromiografia de superfície. A ANOVA de medidas repetidas mostrou efeito apenas na variável velocidade (F=767,1; p<0,001) e as variáveis condição (F=0,010; p=0,990) e interação (F=0,199; p=0,892) não foram significativas. Na eletromiografia, o Root mean Square (RMS) não diferiu nas condições avaliadas, apresentando comportamento padrão sem diferenças significativas. A aplicação do KT independentemente de ser O>I ou I>O muscular, não alterou o recrutamento muscular nem contribuiu para o aumento do desempenho de pico de torque durante as três velocidades.Research, Society and Development2022-01-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/2419810.33448/rsd-v11i1.24198Research, Society and Development; Vol. 11 No. 1; e11311124198Research, Society and Development; Vol. 11 Núm. 1; e11311124198Research, Society and Development; v. 11 n. 1; e113111241982525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIenghttps://rsdjournal.org/index.php/rsd/article/view/24198/21681Copyright (c) 2022 Rafaéle Gomes Correa; Rubens Alexandre da Silva; Débora Alvez Guariglia ; Marieli Ramos Stocco; Márcio Rogério de Oliveira ; Rodrigo Antônio Carvalho Andraushttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessCorrea, Rafaéle GomesSilva, Rubens Alexandre daGuariglia , Débora AlvezStocco, Marieli RamosOliveira , Márcio Rogério deAndraus, Rodrigo Antônio Carvalho2022-01-16T18:08:18Zoai:ojs.pkp.sfu.ca:article/24198Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:42:50.368549Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults
Efecto del método de aplicación kinesio-taping para la activación y resistencia de músculos gastrocnemios en adultos sanos
Efeito do método de aplicação da kinesio taping na ativação e força do músculos gastrocnêmicos em adultos saudáveis
title Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults
spellingShingle Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults
Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults
Correa, Rafaéle Gomes
Dinamômetro de Força Muscular
Eletromiografia
Fita Atlética
Força Muscular
Torque.
Electromyography
Muscle Strength Dynamometer
Muscle Strength
Athletic tape
Torque.
Cinta Atlética
Dinamómetro de Fuerza Muscula
Electromiografía
Fuerza muscula
Torque.
Correa, Rafaéle Gomes
Dinamômetro de Força Muscular
Eletromiografia
Fita Atlética
Força Muscular
Torque.
Electromyography
Muscle Strength Dynamometer
Muscle Strength
Athletic tape
Torque.
Cinta Atlética
Dinamómetro de Fuerza Muscula
Electromiografía
Fuerza muscula
Torque.
title_short Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults
title_full Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults
title_fullStr Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults
Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults
title_full_unstemmed Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults
Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults
title_sort Effect of the kinesio taping application method for the activation and strength of gastrocnemius muscles in healthy adults
author Correa, Rafaéle Gomes
author_facet Correa, Rafaéle Gomes
Correa, Rafaéle Gomes
Silva, Rubens Alexandre da
Guariglia , Débora Alvez
Stocco, Marieli Ramos
Oliveira , Márcio Rogério de
Andraus, Rodrigo Antônio Carvalho
Silva, Rubens Alexandre da
Guariglia , Débora Alvez
Stocco, Marieli Ramos
Oliveira , Márcio Rogério de
Andraus, Rodrigo Antônio Carvalho
author_role author
author2 Silva, Rubens Alexandre da
Guariglia , Débora Alvez
Stocco, Marieli Ramos
Oliveira , Márcio Rogério de
Andraus, Rodrigo Antônio Carvalho
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Correa, Rafaéle Gomes
Silva, Rubens Alexandre da
Guariglia , Débora Alvez
Stocco, Marieli Ramos
Oliveira , Márcio Rogério de
Andraus, Rodrigo Antônio Carvalho
dc.subject.por.fl_str_mv Dinamômetro de Força Muscular
Eletromiografia
Fita Atlética
Força Muscular
Torque.
Electromyography
Muscle Strength Dynamometer
Muscle Strength
Athletic tape
Torque.
Cinta Atlética
Dinamómetro de Fuerza Muscula
Electromiografía
Fuerza muscula
Torque.
topic Dinamômetro de Força Muscular
Eletromiografia
Fita Atlética
Força Muscular
Torque.
Electromyography
Muscle Strength Dynamometer
Muscle Strength
Athletic tape
Torque.
Cinta Atlética
Dinamómetro de Fuerza Muscula
Electromiografía
Fuerza muscula
Torque.
description The objective of this study was to verify the effect of kinesio-taping (KT) application of the origin for muscle insertion (O>I) and insertion for muscle origin (I>O) in healthy participants, through surface electromyography and peak torque of gastrocnemius muscles. A total of 69 participants with an average age of 22.9±5.2 years were evaluated, 41 women with an average age of 22.0±5.1 years, BMI 25.1±4.6 kg/m2, and 28 men with an average age of 22.0±5.1 years, BMI 23.1±3.3 kg/m2, randomized under three conditions: O>I, I>O and no KT (control), repeated three times with five-minute rest between sessions. The peak torque of the gastrocnemius lateral (GML) and medial (GMM) muscles was evaluated at speeds 30º/s 60º/s 120º/s and muscle activity through surface electromyography. Repeated-measurement ANOVA showed effect only on the variable speed (F=767,1; p<0.001) and the variables condition (F=0.010; p=0.990) and interaction (F=0.199; p=0.892) were not significant. In electromyography, Root mean Square (RMS) did not differ in the conditions evaluated, presenting standard behavior without significant differences. The KT application regardless of being O>I or I>O muscular, did not alter the muscle recruitment or contribute to the increase in peak torque performance during the three speeds.
publishDate 2022
dc.date.none.fl_str_mv 2022-01-03
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/24198
10.33448/rsd-v11i1.24198
url https://rsdjournal.org/index.php/rsd/article/view/24198
identifier_str_mv 10.33448/rsd-v11i1.24198
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/24198/21681
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 11 No. 1; e11311124198
Research, Society and Development; Vol. 11 Núm. 1; e11311124198
Research, Society and Development; v. 11 n. 1; e11311124198
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1822178567111311360
dc.identifier.doi.none.fl_str_mv 10.33448/rsd-v11i1.24198